Quantitative analysis of the microstructure of human umbilical vein for assessing feasibility as vessel substitute

被引:14
作者
Li, Wen-Chun [1 ,2 ,3 ]
Zhang, Hong-Mei [1 ]
Wang, Pei-Jun [1 ]
Xi, Gang-Ming [2 ]
Wang, Han-Qin [1 ]
Chen, Yan [1 ]
Deng, Zhao-Hong [1 ]
Zhang, Zheng-Hong [1 ,2 ]
Huang, Tie-Zhu [1 ]
机构
[1] Yunyang Med Coll, Inst Basic Med Sci, Shiyan 442000, Peoples R China
[2] Yunyang Med Coll, Peoples Hosp, Shiyan, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Dept Anat, Wuhan 430074, Peoples R China
关键词
D O I
10.1016/j.avsg.2007.12.021
中图分类号
R61 [外科手术学];
学科分类号
摘要
We explored the feasibility of human umbilical vein (HUV) as a small-caliber vessel substitute. HUVs of 50 fetuses were collected on spontaneous miscarriage or labor with the pregnant women's permission. Gestational age ranged 24-42 weeks, and parturients were 20-30 years old. Each sample was sliced into 5 mm frozen transverse sections and stained with hematoxyline eosin (HE), Weigert, aniline blue, and orange yellow G. The geometric morphological indexes and microstructural component were measured by a computer image analysis system. The media thickness was 0.186, 0.203, 0.237, 0.264, and 0.268 mm at 24-27, 28-32, 33-36, 37-40, and 41-42 weeks, respectively (F = 133.35, p < 0.01); diameters were 1.861, 1.962, 2.303, 2.464, and 2.465 mm (F = 37.35, p < 0.01), respectively. The media thickness and diameter of HUVs increased with gestational age. The elastin content of media increased at 24-40 weeks, but the collagen content and collagen/elastin (C/E) ratio decreased. Elastin content in the proximal segment was higher than in the distal segment [10.16, 6.36 Aa%, (Aa% is the unit of relative content, ie, the ratio of absolute areas to the total tested area of smooth muscle, collagen and elastin in the vascular wall) F = 5.77-12.3, p < 0.05], with the collagen to elastin (C/E) ratio increasing from the proximal to the distal segment (F = 7.63-13.4, p < 0.05). Our results suggest that the microstructural component of HUVs (2.0-3.0 mm caliber) at 37-40 weeks of gestation was similar to that of the small-caliber arteries and had moderate amounts of collagen and elastin and good elasticity, i.e., a good C/E ratio; therefore, HUV may be a substitute for small-caliber arteries (e. g., brachial, ulnar, radial, right coronary, anterior tibial, and posterior tibial). HUV is one of several graft materials that may be used when autogenous saphenous vein is absent or inadequate.
引用
收藏
页码:417 / 424
页数:8
相关论文
共 38 条
[1]  
ANDERSEN LI, 1985, SURGERY, V97, P294
[2]  
ASLAN R, 1992, J CARDIOVASC SURG, V33, P154
[3]   Ajoene inhibits the activation of human endothelial cells induced by porcine cells: implications for xenotransplantation [J].
Benatuil, L ;
Apitz-Castro, R ;
Romano, E .
XENOTRANSPLANTATION, 2003, 10 (04) :368-373
[4]   Development of the human umbilical vein scaffold for cardiovascular tissue engineering applications [J].
Daniel, J ;
Abe, K ;
McFetridge, PS .
ASAIO JOURNAL, 2005, 51 (03) :252-261
[5]   A DECADE OF EXPERIENCE WITH THE GLUTARALDEHYDE-TANNED HUMAN UMBILICAL-CORD VEIN GRAFT FOR REVASCULARIZATION OF THE LOWER-LIMB [J].
DARDIK, H ;
MILLER, N ;
DARDIK, A ;
IBRAHIM, IM ;
SUSSMAN, B ;
BERRY, SM ;
WOLODIGER, F ;
KAHN, M ;
DARDIK, I .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) :336-346
[6]   Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: An analysis of 1275 cases [J].
Dardik, H ;
Wengerter, K ;
Qin, F ;
Pangilinan, A ;
Silvestri, F ;
Wolodiger, F ;
Kahn, M ;
Sussman, B ;
Ibrahim, IM .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) :64-71
[7]   SUCCESSFUL ARTERIAL SUBSTITUTION WITH MODIFIED HUMAN UMBILICAL VEIN [J].
DARDIK, H ;
DARDIK, II .
ANNALS OF SURGERY, 1976, 183 (03) :252-258
[8]  
DARDIK I, 1973, J MED PRIMATOL, V2, P296
[9]  
DOBIN PB, 1969, AM J PHYSIOL, V217, P1644
[10]  
Forbes TL, 2005, CAN J SURG, V48, P311