Malreduction of syndesmosis-Are we considering the anatomical variation?

被引:123
作者
Mukhopadhyay, S. [1 ]
Metcalfe, A. [1 ]
Guha, A. R. [1 ]
Mohanty, K. [1 ]
Hemmadi, S. [1 ]
Lyons, K. [2 ]
O'Doherty, D. [1 ]
机构
[1] Univ Wales Hosp, Dept Orthopaed, Cardiff CF14 4XW, S Glam, Wales
[2] Univ Wales Hosp, Dept Radiol, Cardiff CF14 4XW, S Glam, Wales
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2011年 / 42卷 / 10期
关键词
Malreduction; Syndesmosis; Bilateral; CT; RADIOGRAPHIC MEASUREMENTS; TIBIOFIBULAR SYNDESMOSIS; ANKLE FRACTURES; INJURY;
D O I
10.1016/j.injury.2011.03.019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Previous studies have demonstrated the need for accurate reduction of ankle syndesmosis. Measurement of syndesmosis is difficult on plain radiographs. A computed tomography (CT) scan allows better visualisation of the transverse relationship between the fibula and incisura fibularis. The difference ('G' a term we coined for ease of description) between the fibula and the anterior and posterior facets of the incisura fibularis was compared between normal and injured ankles following syndesmotic fixation in 19 patients. The mean diastasis (MD) was also calculated, representing the average measurement between the fibula and the anterior and posterior incisura. When compared with the normal side, eight out of 19 (42%) cases were found to have a residual diastasis even after fixation across the syndesmosis. However, if a standard value of G (2 mm) was used for the injured leg only, all of the 19 cases would have abnormal values of 'G' following reduction. Our study has clearly demonstrated the need for individualising the assessment method to guide surgeons and radiologists prior to revision surgery. A standard value of 'G' of 2 mm as the normal limit cannot be applied universally, as apparent from the data presented in this study. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1073 / 1076
页数:4
相关论文
共 9 条
[1]   Radiographic measurement of the distal tibiofibular syndesmosis has limited use [J].
Beamer, A ;
van Hemert, WLW ;
Niesing, R ;
Entius, CAC ;
Ginai, AZ ;
Mulder, PGH ;
Swierstra, BA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :227-234
[2]   Observer reliability in ankle radiographic measurements [J].
Brage, ME ;
Bennet, CR ;
Whitehurst, JB ;
Getty, PJ ;
Toledano, A .
FOOT & ANKLE INTERNATIONAL, 1997, 18 (06) :324-329
[3]   MR Imaging of Ankle Inversion Injuries [J].
Campbell, Scot E. ;
Warner, Meredith .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (01) :1-+
[4]   Radiographic and CT evaluation of tibiofibular syndesmotic diastasis: A cadaver study [J].
Ebraheim, NA ;
Lu, JK ;
Yang, H ;
Mekhail, AO ;
Yeasting, RA .
FOOT & ANKLE INTERNATIONAL, 1997, 18 (11) :693-698
[5]   Malreduction of the tibiofibular syndesmosis in ankle fractures [J].
Gardner, Michael J. ;
Demetrakopoulos, Demetris ;
Briggs, Stephen M. ;
Helfet, David L. ;
Lorich, Dean G. .
FOOT & ANKLE INTERNATIONAL, 2006, 27 (10) :788-792
[6]   Chronic tibiofibular syndesmosis injury: The diagnostic efficiency of magnetic resonance imaging and comparative analysis of operative treatment [J].
Han, Seung Hwan ;
Lee, Jin Woo ;
Kim, Sungjun ;
Suh, Jin-Suck ;
Choi, Yoon Rak .
FOOT & ANKLE INTERNATIONAL, 2007, 28 (03) :336-342
[7]   Radiographic measurements do not predict syndesmotic injury in ankle fractures - An MRI study [J].
Nielson, JH ;
Gardner, MJ ;
Peterson, MGE ;
Sallis, JG ;
Potter, HG ;
Helfet, DL ;
Lorich, DG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :216-221
[8]   CHANGES IN TIBIOTALAR AREA OF CONTACT CAUSED BY LATERAL TALAR SHIFT [J].
RAMSEY, PL ;
HAMILTON, W .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03) :356-357
[9]   The effect of fibular malreduction on contact pressures in an ankle fracture malunion model [J].
Thordarson, DB ;
Motamed, S ;
Hedman, T ;
Ebramzadeh, E ;
Bakshian, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (12) :1809-1815