ASSESSMENT OF FACTORS AFFECTING R290 CONCENTRATIONS ARISING FROM LEAKS IN ROOM AIR CONDITIONERS

被引:3
作者
Colbourne, D. [1 ]
Suen, K. O. [2 ]
机构
[1] GIZ Proklima, Dag Hammarskjold Weg 1-5, D-65760 Eschborn, Germany
[2] UCL, Dept Mech Engn, Gower St, London WC1E 6BT, England
来源
13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES | 2018年
关键词
Hydrocarbon refrigerant; R290; flammable; leakage; concentration; safety standards; air conditioner;
D O I
10.18462/iir.gl.2018.1103
中图分类号
O414.1 [热力学];
学科分类号
摘要
Currently R290 is used to a small extent in room air conditioners, such as split, portable and window types. Products are limited to relatively small cooling capacities due to refrigerant charge sizes being constrained to around 300 400 g, on account of maximum charge formulae within standards IEC 60335-2-40, ISO 5149-1 and EN 378-1. This is especially challenging in warm countries where the cooling load is greater and charge sizes need to be larger. Work is underway to improve maximum charge size determination methods for a given room size. As a contribution to this on going process, further research has been carried out to understand the factors that affect development of flammable concentrations within rooms in event of a leak. Parameters related to the characteristics of room air conditioners and installations have been investigated experimentally by measuring R290 concentrations from releases and selected findings are described.
引用
收藏
页码:25 / 35
页数:11
相关论文
共 21 条
  • [1] [Anonymous], 603352242010A12012 I
  • [2] [Anonymous], 600791012015 EN
  • [3] [Anonymous], 2009, 603352402003A2 EN
  • [4] [Anonymous], 514912014A12015 ISO
  • [5] Equipment design and installation features to disperse refrigerant releases in rooms - part I: experiments and analysis
    Colbourne, D
    Suen, KO
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (06): : 667 - 673
  • [6] Colbourne D., 2013, P IIF IIR COMPR 2013
  • [7] Colbourne D., 2012, P 10 IR GUST LOR C N
  • [8] Colbourne D., P 11 IIR GUST LOR C
  • [9] Review of standards for the use of hydrocarbon refrigerants in A/C, heat pump and refrigeration equipment
    Corberan, Jose M.
    Segurado, Jacobo
    Colbourne, Daniel
    Gonzalvez, Jose
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (04): : 748 - 756
  • [10] Deutsche Gesellschaft fur Internationale Zusammenarbeit (GIZ), 2011, OP SPLIT COND SYST H