Gel-based immunoassay for non-instrumental detection of pyrene in water samples

被引:21
|
作者
Goryacheva, Irina Yu. [1 ]
Beloglazova, Natalia V. [1 ]
Eremin, Sergei A. [2 ]
Mikhirev, Dmitry A. [2 ]
Niessner, Reinhard [3 ]
Knopp, Dietmar [3 ]
机构
[1] Saratov NG Chernyshevskii State Univ, Fac Chem, Dept Common & Inorgan Chem, Saratov 410012, Russia
[2] Moscow MV Lomonosov State Univ, Dept Chem Enzymol, Moscow 119992, Russia
[3] Tech Univ Munich, Inst Hydrochem & Chem Balneol, Chair Analyt Chem, D-81377 Munich, Germany
关键词
enzyme immunoassay; immunoaffinity column; on-site method; pyrene; screening; non-instrumental test; visual detection;
D O I
10.1016/j.talanta.2007.11.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new qualitative immunologically based tube test for non-instrumental detection of pyrene (PYR) in water samples was developed. The method combines the pre-concentration of analyte by immunoextraction and its detection by immunoassay using Sepharose 4B-immobilized IgG-fraction of a polyclonal anti-PYR antiserum (immunoaffinity gel) and I-pyrenebutyric acid-horseradish peroxidase conjugate (PYR-BA-HRP). The immunoaffinity gel was placed in a standard 1-ml SPE column through which a 10-ml aliquot of water sample spiked with 10% acetonitrile was passed. Following, free antibody binding sites were detected by application of PYR-BA-HRP. Four minutes after addition of the chromogenic substrate the results were visually evaluated by occurring or stayed away blue colour development for negative and positive samples, respectively. Total time for assay was about 15 min for six samples. Under optimized conditions a cut-off level for pyrene of 0.04 ng ml(-1) was found. At this defined concentration, a set of spiked samples (n = 175) was analyzed and very low rates of false negatives (1.2%) and false positives (4.6%) determined which fulfils the requirement set by Commission Decision 2002/657/EC for a screening method. No interference by other PAH compounds like naphthalene, fluoranthene, phenanthrene, anthracene, and benzo[a]pyrene at a concentration of 20 ng ml(-1), i.e., 500-fold excess compared to the defined cut-off level was observed. Different water types like surface water, tap water, bottled water, and melted snow were analyzed for PYR contamination by the proposed method and results confirmed by HPLC-FLD. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:517 / 522
页数:6
相关论文
共 50 条
  • [1] A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples
    Yuan, Meng
    Sheng, Wei
    Zhang, Yan
    Wang, Junping
    Yang, Yijin
    Zhang, Shuguang
    Goryacheva, Irina Yu.
    Wang, Shuo
    ANALYTICA CHIMICA ACTA, 2012, 751 : 128 - 134
  • [2] Novel gel-based rapid test for non-instrumental detection of ochratoxin A in beer
    Goryacheva, I. Y.
    Basova, E. Y.
    Van Peteghem, C.
    Eremin, S. A.
    Pussemier, L.
    Motte, J. -C.
    De Saeger, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) : 723 - 727
  • [3] Novel gel-based rapid test for non-instrumental detection of ochratoxin A in beer
    I. Y. Goryacheva
    E. Y. Basova
    C. Van Peteghem
    S. A. Eremin
    L. Pussemier
    J.-C. Motte
    S. De Saeger
    Analytical and Bioanalytical Chemistry, 2008, 390 : 723 - 727
  • [4] A comparison of horseradish peroxidase, gold nanoparticles and qantum dots as labels in non-instrumental gel-based immunoassay
    Natalia V Beloglazova
    Irina Yu Goryacheva
    Reinhard Niessner
    Dietmar Knopp
    Microchimica Acta, 2011, 175 : 361 - 367
  • [5] A comparison of horseradish peroxidase, gold nanoparticles and qantum dots as labels in non-instrumental gel-based immunoassay
    Beloglazova, Natalia V.
    Goryacheva, Irina Yu
    Niessner, Reinhard
    Knopp, Dietmar
    MICROCHIMICA ACTA, 2011, 175 (3-4) : 361 - 367
  • [6] Detection of herbicides by non-instrumental immunoassay techniques
    Lukin, YV
    Pavlova, IS
    Lyubavina, I
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 26 - ENVR
  • [7] A paper-based colorimetric assay with non-instrumental detection for determination of boron in water samples
    Pena-Pereira, Francisco
    Velazquez, Angie
    Lavilla, Isela
    Bendicho, Carlos
    TALANTA, 2020, 208 (208)
  • [8] Detection of 2,4-dichlorophenoxyacetic acid by non-instrumental latex immunoassay
    Lukin, YV
    Generalova, AN
    Tyrtysh, TV
    Eremin, SA
    IMMUNOCHEMICAL TECHNOLOGY FOR ENVIRONMENTAL APPLICATIONS, 1997, 657 : 97 - 105
  • [9] Detection of Multiple SNPs in Numerous Samples with Polyacrylamide Gel-Based Microarray
    Cheng, Lu
    Sun, Beili
    Sun, Yu
    Xiao, Pengfeng
    Ge, Qinyu
    Zheng, Yuanzhuo
    Ke, Xiaoyan
    Zhou, Ying
    Zhang, Minghao
    Chen, Ping
    Lu, Zuhong
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2010, 10 (01) : 479 - 486
  • [10] Visual Non-Instrumental On-Site Detection of Fumonisin B1, B2, and B3 in Cereal Samples Using a Clean-Up Combined with Gel-Based Immunoaffinity Test Column Assay
    Sheng, Wei
    Wu, Hesen
    Ji, Weihong
    Li, Zhi
    Chu, Fangyu
    Wang, Shuo
    TOXINS, 2018, 10 (04):