Gel-based immunoassay for non-instrumental detection of pyrene in water samples

被引:21
作者
Goryacheva, Irina Yu. [1 ]
Beloglazova, Natalia V. [1 ]
Eremin, Sergei A. [2 ]
Mikhirev, Dmitry A. [2 ]
Niessner, Reinhard [3 ]
Knopp, Dietmar [3 ]
机构
[1] Saratov NG Chernyshevskii State Univ, Fac Chem, Dept Common & Inorgan Chem, Saratov 410012, Russia
[2] Moscow MV Lomonosov State Univ, Dept Chem Enzymol, Moscow 119992, Russia
[3] Tech Univ Munich, Inst Hydrochem & Chem Balneol, Chair Analyt Chem, D-81377 Munich, Germany
关键词
enzyme immunoassay; immunoaffinity column; on-site method; pyrene; screening; non-instrumental test; visual detection;
D O I
10.1016/j.talanta.2007.11.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new qualitative immunologically based tube test for non-instrumental detection of pyrene (PYR) in water samples was developed. The method combines the pre-concentration of analyte by immunoextraction and its detection by immunoassay using Sepharose 4B-immobilized IgG-fraction of a polyclonal anti-PYR antiserum (immunoaffinity gel) and I-pyrenebutyric acid-horseradish peroxidase conjugate (PYR-BA-HRP). The immunoaffinity gel was placed in a standard 1-ml SPE column through which a 10-ml aliquot of water sample spiked with 10% acetonitrile was passed. Following, free antibody binding sites were detected by application of PYR-BA-HRP. Four minutes after addition of the chromogenic substrate the results were visually evaluated by occurring or stayed away blue colour development for negative and positive samples, respectively. Total time for assay was about 15 min for six samples. Under optimized conditions a cut-off level for pyrene of 0.04 ng ml(-1) was found. At this defined concentration, a set of spiked samples (n = 175) was analyzed and very low rates of false negatives (1.2%) and false positives (4.6%) determined which fulfils the requirement set by Commission Decision 2002/657/EC for a screening method. No interference by other PAH compounds like naphthalene, fluoranthene, phenanthrene, anthracene, and benzo[a]pyrene at a concentration of 20 ng ml(-1), i.e., 500-fold excess compared to the defined cut-off level was observed. Different water types like surface water, tap water, bottled water, and melted snow were analyzed for PYR contamination by the proposed method and results confirmed by HPLC-FLD. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:517 / 522
页数:6
相关论文
共 19 条
  • [1] Detection and quantification of PAH in drinking water by front-face fluorimetry on a solid sorbent and PLS analysis
    Algarra, M
    Jiménez, V
    de Violet, PF
    Lamotte, M
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (04) : 1103 - 1110
  • [2] Determination of PAHs in river water samples by ELISA
    Barceló, D
    Oubiña, A
    Salau, JS
    Perez, S
    [J]. ANALYTICA CHIMICA ACTA, 1998, 376 (01) : 49 - 53
  • [3] Immunochemical detection of polycyclic aromatic hydrocarbons (PAHs)
    Fähnrich, KA
    Pravda, M
    Guilbault, GG
    [J]. ANALYTICAL LETTERS, 2002, 35 (08) : 1269 - 1300
  • [4] Disposable amperometric immunosensor for the detection of polycyclic aromatic hydrocarbons (PAHs) using screen-printed electrodes
    Fähnrich, KA
    Pravda, M
    Guilbault, GG
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) : 73 - 82
  • [5] Highly sensitive and interference-free simultaneous detection of two polycyclic aromatic hydrocarbons at parts-per-trillion levels using a surface plasmon resonance immunosensor
    Gobi, KV
    Miura, N
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 103 (1-2) : 265 - 271
  • [6] Approach for ochratoxin A fast screening in spices using clean-up tandem immunoassay columns with confirmation by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS)
    Goryacheva, I. Yu.
    De Saeger, S.
    Lobeau, M.
    Eremin, S. A.
    Barna-Vetro, I.
    Van Peteghem, C.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 38 - 45
  • [7] Development of a fluorescence polarization immunoassay for polycyclic aromatic hydrocarbons
    Goryacheva, Irina Yu
    Eremin, Sergei A.
    Shutaleva, Ekaterina A.
    Suchanek, Miloslav
    Niessner, Reinhard
    Knopp, Dietmar
    [J]. ANALYTICAL LETTERS, 2007, 40 (07) : 1445 - 1460
  • [8] Simultaneous non-instrumental detection of aflatoxin B1 and ochratoxin A using a clean-up tandem immunoassay column
    Goryacheva, Irina Yu.
    De Saeger, Sarah
    Delmulle, Barbara
    Lobeau, Marieke
    Eremin, Sergei A.
    Barna-Vetro, Ildiko
    Van Peteghem, Carlos
    [J]. ANALYTICA CHIMICA ACTA, 2007, 590 (01) : 118 - 124
  • [9] Determination of polycyclic aromatic hydrocarbons in bulk precipitation and runoff waters in an urban region (Poland)
    Grynkiewicz, M
    Polkowska, Z
    Namiesnik, J
    [J]. ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 361 - 369
  • [10] Determination of polycyclic aromatic hydrocarbons in contaminated water and soil samples by immunological and chromatographic methods
    Knopp, D
    Seifert, M
    Väänänen, V
    Niessner, R
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (10) : 2035 - 2041