Axial load behaviour of high-strength rectangular concrete-filled steel tubular stub columns

被引:190
作者
Liu, DL [1 ]
Gho, WM
机构
[1] Shenzhen Univ, Dept Civil Engn, Shenzhen 518060, Guangdong Provi, Peoples R China
[2] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
axial loading; CFT column; concrete; high-strength; steel;
D O I
10.1016/j.tws.2005.03.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation into the axial load behaviour of rectangular concrete-filled steel tubular (CFT) stub columns. A total of 26 specimens were tested under concentric compression. The primary test parameters were material strengths (f(c)' = 55 - 106 MPa; f(y) = 300 and 495 MPa) and cross-sectional aspect ratio (1.0-2.0). Favourable ductility performance was observed for all specimens during the tests. A comparison of axial load capacity between the tests and the design codes shows that ACI and AISC give safe estimation by 7 and 8%, respectively. On the other hand, EC4 overestimates the ultimate capacity of the specimens fabricated from mild steel and high-strength concrete. A fibre model is developed to evaluate the axial load behaviour of the specimens. Calibration of the model against the test data suggests that it can closely predict the non-linear behaviour of high-strength rectangular CFT stub columns. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1131 / 1142
页数:12
相关论文
共 12 条
[1]  
[Anonymous], 1999, LOAD RES FACT DES SP
[2]  
*ASTM, 1997, TEST METH TENS TEST
[3]   Behavior of eccentrically loaded concrete-filled steel tubular columns [J].
Fujimoto, T ;
Mukai, A ;
Nishiyama, I ;
Sakino, K .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (02) :203-212
[4]   Tests on stub columns of concrete-filled RHS sections [J].
Han, LH .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (03) :353-372
[5]  
Kilpatrick AE, 1999, ACI STRUCT J, V96, P642
[6]   Behaviour of high strength rectangular concrete-filled steel hollow section columns under eccentric loading [J].
Liu, DL .
THIN-WALLED STRUCTURES, 2004, 42 (12) :1631-1644
[7]   Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns [J].
Liu, DL ;
Gho, WM ;
Yuan, H .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (12) :1499-1515
[8]  
RANGAN BV, 1992, ACI STRUCT J, V89, P676
[9]   Behavior of centrally loaded concrete-filled steel-tube short columns [J].
Sakino, K ;
Nakahara, H ;
Morino, S ;
Nishiyama, A .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2004, 130 (02) :180-188
[10]   Axially loaded concrete-filled steel tubes [J].
Schneider, SP .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10) :1125-1138