Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

被引:37
|
作者
Alfadhli, Eman [1 ]
Osman, Eman [1 ]
Basri, Taghreed [2 ]
机构
[1] Taibah Univ, Medina, Saudi Arabia
[2] Madina Matern & Children Hosp, Medina, Saudi Arabia
来源
DIABETOLOGY & METABOLIC SYNDROME | 2016年 / 8卷
关键词
Gestational diabetes; Continuous glucose monitoring system; SMBG; Maternal glycemic control; Pregnancy outcomes; GLYCEMIC CONTROL; PREGNANCY;
D O I
10.1186/s13098-016-0161-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. Methods: This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian (R) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. Results: HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Conclusion: Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes A randomized controlled trial
    Secher, Anna L.
    Ringholm, Lene
    Andersen, Henrik U.
    Damm, Peter
    Mathiesen, Elisabeth R.
    DIABETES CARE, 2013, 36 (07) : 1877 - 1883
  • [32] Flash glucose monitoring system in gestational diabetes: a study of accuracy and usability
    Lopes, Sara Campos
    Brito, Ana Isabel
    Barbosa, Mariana
    Matos, Ana Catarina
    Pereira, Maria Lopes
    Monteiro, Ana Margarida
    Fernandes, Vera
    HORMONES-INTERNATIONAL JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2023, 22 (04): : 703 - 713
  • [33] Modelling potential cost savings from use of real-time continuous glucose monitoring in pregnant women with Type 1 diabetes
    Murphy, H. R.
    Feig, D. S.
    Sanchez, J. J.
    de Portu, S.
    Sale, A.
    DIABETIC MEDICINE, 2019, 36 (12) : 1652 - 1658
  • [34] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [35] Association between Real-Time Continuous Glucose Monitor Use and Diabetes-Related Medical Costs for Patients with Type 2 Diabetes
    Norman, Gregory J.
    Paudel, Misti L.
    Parkin, Christopher G.
    Bancroft, Tim
    Lynch, Peter M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (07) : 520 - 524
  • [36] Clinical and economic outcomes of continuous glucose monitoring system (CGMS) in patients with diabetes mellitus: A systematic literature review
    Aggarwal, Aditi
    Pathak, Smit
    Goyal, Richa
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 186
  • [37] Glycemic profile of women with normoglycemia and gestational diabetes mellitus during early pregnancy using continuous glucose monitoring system
    Singh, Charandeep
    Gupta, Yashdeep
    Goyal, Alpesh
    Kalaivani, Mani
    Garg, Vineeta
    Bharti, Juhi
    Singhal, Seema
    Kachhawa, Garima
    Kulshrestha, Vidushi
    Kumari, Rajesh
    Mahey, Reeta
    Sharma, Jai B.
    Bhatla, Neerja
    Khadgawat, Rajesh
    Gupta, Nandita
    Tandon, Nikhil
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2020, 169
  • [38] Improvement of metabolic control after 3-month use of real-time continuous glucose monitoring in patients with type 1 diabetes: a multicenter study in Greece
    Eleftheriadou, Ioanna
    Didangelos, Triantafyllos
    Pappas, Angelos C.
    Anastasiou, Eleni
    Vasilopoulos, Charalampos
    Zoupas, Christos
    Manes, Christos
    Tsatsoulis, Agathocles
    Benroubi, Marianna
    Pangalos, Emmanuel
    Thomakos, Petros
    Gerasimidi-Vazeou, Andriani
    Tentolouris, Nikolaos
    HORMONES-INTERNATIONAL JOURNAL OF ENDOCRINOLOGY AND METABOLISM, 2019, 18 (04): : 443 - 450
  • [39] Improvement of metabolic control after 3-month use of real-time continuous glucose monitoring in patients with type 1 diabetes: a multicenter study in Greece
    Ioanna Eleftheriadou
    Triantafyllos Didangelos
    Angelos C. Pappas
    Eleni Anastasiou
    Charalampos Vasilopoulos
    Christos Zoupas
    Christos Manes
    Agathocles Tsatsoulis
    Marianna Benroubi
    Emmanuel Pangalos
    Petros Thomakos
    Andriani Gerasimidi-Vazeou
    Nikolaos Tentolouris
    Hormones, 2019, 18 : 443 - 450
  • [40] Real-Time Continuous Glucose Monitoring Significantly Reduces Severe Hypoglycemia in Hypoglycemia-Unaware Patients With Type 1 Diabetes
    Choudhary, Pratik
    Ramasamy, Sharmin
    Green, Louisa
    Gallen, Geraldine
    Pender, Siobhan
    Brackenridge, Anna
    Amiel, Stephanie A.
    Pickup, John C.
    DIABETES CARE, 2013, 36 (12) : 4160 - 4162