Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

被引:37
|
作者
Alfadhli, Eman [1 ]
Osman, Eman [1 ]
Basri, Taghreed [2 ]
机构
[1] Taibah Univ, Medina, Saudi Arabia
[2] Madina Matern & Children Hosp, Medina, Saudi Arabia
来源
DIABETOLOGY & METABOLIC SYNDROME | 2016年 / 8卷
关键词
Gestational diabetes; Continuous glucose monitoring system; SMBG; Maternal glycemic control; Pregnancy outcomes; GLYCEMIC CONTROL; PREGNANCY;
D O I
10.1186/s13098-016-0161-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. Methods: This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian (R) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. Results: HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Conclusion: Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Comparison of an Intermittently Scanned (Flash) Continuous Glucose Monitoring System to Standard Self-Monitoring of Capillary Blood Glucose in Gestational Diabetes Mellitus
    Hussain, Farrah N.
    Raymond, Samantha
    Feldman, Kristina M.
    Scarpelli-Shchur, Sophia
    Strauss, Tirtza S.
    Al-Ibraheemi, Zainab
    Brustman, Lois
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (11) : 1149 - 1157
  • [12] Controversies and Advances in Gestational Diabetes-An Update in the Era of Continuous Glucose Monitoring
    Carreiro, Marina P.
    Nogueira, Anelise I.
    Ribeiro-Oliveira, Antonio, Jr.
    JOURNAL OF CLINICAL MEDICINE, 2018, 7 (02)
  • [13] The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes
    Dulce Adelaida Rivera-Ávila
    Alejandro Iván Esquivel-Lu
    Carlos Rafael Salazar-Lozano
    Kyla Jones
    Svetlana V. Doubova
    BMC Endocrine Disorders, 21
  • [14] The effects of professional continuous glucose monitoring as an adjuvant educational tool for improving glycemic control in patients with type 2 diabetes
    Rivera-Avila, Dulce Adelaida
    Esquivel-Lu, Alejandro Ivan
    Salazar-Lozano, Carlos Rafael
    Jones, Kyla
    Doubova, Svetlana V.
    BMC ENDOCRINE DISORDERS, 2021, 21 (01)
  • [15] Benefits of Real-Time Continuous Glucose Monitoring in Pregnancy
    Yamamoto, Jennifer M.
    Murphy, Helen R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S8 - S14
  • [16] Continuous Glucose Monitoring and Time in Range: Association with Adverse Outcomes among People with Type 2 or Gestational Diabetes Mellitus
    Bitar, Ghamar
    Cornthwaite, Joycelyn A.
    Sadek, Sandra
    Ghorayeb, Tala
    Daye, Nahla
    Nazeer, Sarah
    Ghafir, Danna
    Cornthwaite, John
    Chauhan, Suneet P.
    Sibai, Baha M.
    Bartal, Michal Fishel
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e1370 - e1377
  • [17] Continuous Glucose Monitoring for the Diagnosis of Gestational Diabetes Mellitus: A Pilot Study
    Di Filippo, Daria
    Ahmadzai, Marrwah
    Chang, Melissa Han Yiin
    Horgan, Ksana
    Ong, Ru Min
    Darling, Justine
    Akhtar, Mahmood
    Henry, Amanda
    Welsh, Alec
    JOURNAL OF DIABETES RESEARCH, 2022, 2022
  • [18] Use of Short-Term Real-Time Continuous Glucose Monitoring in Type 1 Diabetes Patients on Continuous Intraperitoneal Insulin Infusion: A Feasibility Study
    Logtenberg, Susan J. J.
    Kleefstra, Nanne
    Groenier, Klaas H.
    Gans, Rijk O. B.
    Bilo, Henk J. G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (05) : 293 - 299
  • [19] Use of telemedicine in subjects with type 1 diabetes equipped with an insulin pump and real-time continuous glucose monitoring
    Gonzalez-Molero, Inmaculada
    Dominguez-Lopez, Marta
    Guerrero, Mercedes
    Carreira, Monica
    Caballero, Felix
    Rubio-Martin, Eleazara
    Linares, Francisca
    Cardona, Isabel
    Teresa Anarte, Maria
    Soledad Ruiz de Adana, Maria
    Soriguer, Federico
    JOURNAL OF TELEMEDICINE AND TELECARE, 2012, 18 (06) : 328 - 332
  • [20] Diabetes: the role of continuous glucose monitoring
    Kluemper, Julianna Rivich
    Smith, Alexandria
    Wobeter, Brooke
    DRUGS IN CONTEXT, 2022, 11