Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

被引:37
|
作者
Alfadhli, Eman [1 ]
Osman, Eman [1 ]
Basri, Taghreed [2 ]
机构
[1] Taibah Univ, Medina, Saudi Arabia
[2] Madina Matern & Children Hosp, Medina, Saudi Arabia
来源
DIABETOLOGY & METABOLIC SYNDROME | 2016年 / 8卷
关键词
Gestational diabetes; Continuous glucose monitoring system; SMBG; Maternal glycemic control; Pregnancy outcomes; GLYCEMIC CONTROL; PREGNANCY;
D O I
10.1186/s13098-016-0161-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. Methods: This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian (R) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. Results: HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Conclusion: Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes
    Eman Alfadhli
    Eman Osman
    Taghreed Basri
    Diabetology & Metabolic Syndrome, 8
  • [2] Real-Time Continuous Glucose Monitoring in Gestational Diabetes: A Randomized Controlled Trial
    Lane, Andrew S.
    Mlynarczyk, Malgorzata A.
    de Veciana, Margarita
    Green, Lauren M.
    Baraki, Dana I.
    Abuhamad, Alfred Z.
    AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (09) : 891 - 897
  • [3] Practical Considerations for Using Continuous Glucose Monitoring in Patients with Gestational Diabetes Mellitus
    Castorino, Kristin
    Durnwald, Celeste
    Ehrenberg, Stacey
    Ehrhardt, Nicole
    Isaacs, Dianna
    Levy, Carol J.
    Valent, Amy M.
    JOURNAL OF WOMENS HEALTH, 2025, 34 (01) : 10 - 20
  • [4] Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
    Jackson, Melanie A.
    Ahmann, Andrew
    Shah, Viral N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S27 - S34
  • [5] Pilot Study for Use of Intermittently Scanned Continuous Glucose Monitoring in Women with Gestational Diabetes
    O'Malley, Grenye
    Arumugam, Dushyanthy
    Ogyaadu, Selassie
    Levister, Camilla
    Nosova, Emily
    Vieira, Luciana
    Levy, Carol J.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (01): : 259 - 261
  • [6] Continuous glucose monitoring in individuals undergoing gestational diabetes screening
    Bartal, Michal Fishel
    Cornthwaite, Joycelyn Ashby
    Ghafir, Danna
    Ward, Clara
    Nazeer, Sarah A.
    Blackwell, Sean C.
    Pedroza, Claudia
    Chauhan, Suneet P.
    Sibai, Baha M.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 229 (04)
  • [7] Evaluation of a new real-time blood continuous glucose monitoring system in pregnant women without gestational diabetes - A pilot study
    Porter, H
    Lookinland, S
    Belfort, MA
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2004, 18 (02) : 93 - 102
  • [8] The Use of Continuous Glucose Monitoring in Patients with Type 2 Diabetes
    Meade, Lisa T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (02) : 190 - 195
  • [9] Evaluation of a Novel Real-Time Continuous Glucose-Monitoring System for Use in Cats
    Moretti, S.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Wichert, B.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (01): : 120 - 126
  • [10] Sustainable Use of a Real-Time Continuous Glucose Monitoring System from 2018 to 2020
    van der Linden, Joost
    Welsh, John B.
    Walker, Tomas C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (07) : 508 - 511