A comparative finite element analysis of artificial intervertebral disc replacement and pedicle screw fixation of the lumbar spine

被引:13
作者
Biswas, Jayanta Kumar [1 ]
Malas, Anindya [1 ]
Majumdar, Sourav [2 ]
Rana, Masud [3 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Patna, Bihar, India
[2] Guru Nanak Inst Technol, Dept Appl Sci & Humanities, Kolkata, W Bengal, India
[3] Indian Inst Engn Sci & Technol, Dept Aerosp Engn & Appl Mech, Sibpur, W Bengal, India
关键词
Pedicle screw; artificial disc replacement; lumbar spine; finite element analysis; FIBER-REINFORCED-POLYETHERETHERKETONE; DIFFERENT ROD MATERIALS; CERVICAL ARTHROPLASTY; PRODISC-II; IMPLANT; MOTION; BIOMECHANICS; KINEMATICS; STIFFNESS; FUSION;
D O I
10.1080/10255842.2022.2039130
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Titanium alloy-based Pedicle screw-rod fusion is a very common technique to provide higher fusion regularity than other methods. In recent times, Carbon-fibre-reinforced (CFR)-PEEK rod is used to better reduce the fusion rate. Alternatively, total disc replacement (TDR) is also very common for the non-fusion treatment method for degenerative disc disease (DDD). This study aims to investigate flexibility (ROM), stability, stress condition in implant, implant adjacent bone of the implanted lumbar spine during different physiological movements and loading environments. The finite element (FE) intact model of the lumbar spine (L2-L5) with two-level pedicle screw-rod fusion at L3-L4-L5 and two-level artificial disc replacement was developed. CFR-PEEK was taken for rod for semi-rigid fusion. UHMWPE was taken as core part of the artificial disc. The FE models were simulated under 6, 8 and 10 Nm moments in left right lateral bending, flexion and extension movements. The total ROM was reduced for two-level pedicle screw fixation and increased for the artificial disc replacement model during flexion extension compared to the intact spine. The total ROM was reduced by around 54% and 25% for two-level fixation and increased by 30% and 19.5% for artificial disc replacement spine, under flexion-extension and left-right lateral bending respectively. For screw fixation, the ROM increased by 15% and 18% reduced by 4.5% and 14% for disc replacement at the adjacent segments for flexion-extension and left-right lateral bending.
引用
收藏
页码:1812 / 1820
页数:9
相关论文
共 39 条
[1]   The effect of arthrodesis, implant stiffness, and time on the canine lumbar spine [J].
Asher, Marc A. ;
Carson, William L. ;
Hardacker, James W. ;
Lark, Richard G. ;
Lai, Sue Min .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (08) :549-559
[2]   Review on the use of medical imaging in orthopedic biomechanics: finite element studies [J].
Barkaoui, Abdelwahed ;
Oumghar, Imane Ait ;
Ben Kahla, Rabeb .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2021, 9 (05) :535-554
[3]   BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A FINITE ELEMENT STUDY [J].
Bhattacharya, Shambo ;
Roy, Sandipan ;
Rana, Masud ;
Banerjee, Sreerup ;
Karmakar, Santanu Kumar ;
Biswas, Jayanta Kumar .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (04)
[4]   Artificial intervertebral disc replacement to provide dynamic stability to the lumbar spine: A finite element study [J].
Biswas J.Kr. ;
Roy S. ;
Majumder S. ;
Karmakar S.Kr. ;
Saha S. ;
Roychowdhury A. .
Journal of Long-Term Effects of Medical Implants, 2018, 28 (02) :101-109
[5]   A comparison of rigid, semi-rigid and flexible spinal stabilization devices: A finite element study [J].
Biswas, Jayanta Kumar ;
Roy, Sandipan ;
Rana, Masud ;
Haider, Subhasish .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) :1292-1298
[6]   Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: A finite element study [J].
Biswas, Jayanta Kumar ;
Rana, Masud ;
Majumder, Santanu ;
Karmakar, Santanu Kumar ;
Roychowdhury, Amit .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) :258-265
[7]   Failure analysis of broken pedicle screws on spinal instrumentation [J].
Chen, CS ;
Chen, WJ ;
Cheng, CK ;
Jao, SHE ;
Chueh, SC ;
Wang, CC .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) :487-496
[8]   ProDisc artificial total lumbar disc replacement: Introduction and early results from the United States clinical trial [J].
Delamarter, RB ;
Fribourg, DM ;
Kanim, LFA ;
Bae, H .
SPINE, 2003, 28 (20) :S167-S175
[9]   ProDisc-C An In Vivo Kinematic Study [J].
Duggal, Neil ;
Bertagnoli, Rudolf ;
Rabin, Doron ;
Wharton, Nicholas ;
Kowalczyk, Izabela .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (05) :334-339
[10]   Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation [J].
Faizan, Ahmad ;
Goel, Vijay K. ;
Garfin, Steven R. ;
Bono, Christopher M. ;
Serhan, Hassan ;
Biyani, Ashok ;
Elgafy, Hossein ;
Krishna, Manoj ;
Friesem, Tai .
EUROPEAN SPINE JOURNAL, 2012, 21 :S653-S662