End-tidal carbon dioxide levels during resuscitation and carbon dioxide levels in the immediate neonatal period and intraventricular haemorrhage

被引:13
|
作者
Tamura, Kentaro [1 ,2 ]
Williams, Emma E. [1 ]
Dassios, Theodore [1 ,3 ]
Pahuja, Anoop [1 ]
Hunt, Katie A. [1 ]
Murthy, Vadivelam [1 ]
Bhat, Prashanth [1 ]
Bhat, Ravindra [3 ]
Milner, Anthony [1 ]
Greenough, Anne [1 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Women & Childrens Hlth, Sch Life Course Sci, Fac Life Sci & Med, London, England
[2] Toyama Univ Hosp, Maternal & Perinatal Ctr, Div Neonatol, Toyama, Japan
[3] Kings Coll Hosp NHS Fdn Trust, Neonatal Intens Care Ctr, London, England
[4] Kings Coll London, Asthma UK Ctr Allerg Mech Asthma, London, England
[5] Guys & St Thomas NHS Fdn Trust, NIHR Biomed Res Ctr, London, England
[6] Kings Coll London, London, England
关键词
Carbon dioxide; End-tidal carbon dioxide; Intraventricular haemorrhage; Prematurity; Resuscitation; MASK VENTILATION; INFANTS; FLUCTUATIONS; OXYGENATION; PRESSURE;
D O I
10.1007/s00431-019-03543-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Abnormal levels of end-tidal carbon dioxide (EtCO2) during resuscitation in the delivery suite are associated with intraventricular haemorrhage (IVH) development. Our aim was to determine whether carbon dioxide (CO2) levels in the first 3 days after birth reflected abnormal EtCO2 levels in the delivery suite, and hence, a prolonged rather than an early insult resulted in IVH. In addition, we determined if greater EtCO(2)level fluctuations during resuscitation occurred in infants who developed IVH. EtCO2 levels during delivery suite resuscitation and CO2 levels on the neonatal unit were evaluated in 58 infants (median gestational age 27.3 weeks). Delta EtCO2 was the difference between the highest and lowest level of EtCO2. Thirteen infants developed a grade 3-4 IVH (severe group). There were no significant differences in CO2 levels between those who did and did not develop an IVH (or severe IVH) on the NICU. The delta EtCO2 during resuscitation differed between infants with any IVH (6.2 (5.4-7.5) kPa) or no IVH (3.8 (2.7-4.3) kPA) (p < 0.001) after adjusting for differences in gestational age. Delta EtCO2 levels gave an area under the ROC curve of 0.940 for prediction of IVH. Conclusion: The results emphasize the importance of monitoring EtCO2 levels in the delivery suite.What is Known:center dot Abnormal levels of carbon dioxide (CO2) in the first few days after birth and abnormal end-tidal CO(2)levels (EtCO2) levels during resuscitation are associated in preterm infants with the risk of developing intraventricular haemorrhage (IVH).What is New:center dot There were no significant differences in NICU CO(2)levels between those who developed an IVH or no IVH.center dot There was a poor correlation between delivery suite ETCO(2)levels and NICU CO(2)levels.center dot Large fluctuations in EtCO(2)during resuscitation in the delivery suite were highly predictive of IVH development in preterm infants.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 50 条
  • [31] End-tidal carbon dioxide after sodium bicarbonate infusion during mechanical ventilation or ongoing cardiopulmonary resuscitation
    Roh, Young-Il
    Kim, Hyung Il
    Kim, Sun Ju
    Cha, Kyoung-Chul
    Jung, Woo Jin
    Park, Yeon Jae
    Hwang, Sung Oh.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2024, 76 : 211 - 216
  • [32] EFFECT OF EPINEPHRINE ON END-TIDAL CARBON-DIOXIDE MONITORING DURING CPR
    MARTIN, GB
    GENTILE, NT
    PARADIS, NA
    MOEGGENBERG, J
    APPLETON, TJ
    NOWAK, RM
    ANNALS OF EMERGENCY MEDICINE, 1990, 19 (04) : 396 - 398
  • [33] Effect of different drugs on end-tidal carbon dioxide during rodent CPR
    Pan Tiecheng
    Zhou Shuhua
    Wolfgang Studer
    Martin von Planta
    Daniel Scheidegger
    Current Medical Science, 1997, 17 (4) : 244 - 246
  • [34] Effect of Different Drugs on End-tidal Carbon Dioxide during Rodent CPR
    潘铁成
    周淑华
    JournalofTongjiMedicalUniversity, 1997, (04) : 244 - 246
  • [35] Uses and pitfalls of measurement of end-tidal carbon dioxide during cardiac arrest
    Nicholson, Tonia C.
    Paiva, Edison F.
    CURRENT OPINION IN CRITICAL CARE, 2020, 26 (06) : 612 - 616
  • [36] End-tidal carbon dioxide monitoring stabilized hemodynamic changes during ECT
    Saito, S
    Kadoi, Y
    Nihishara, F
    Aso, C
    Goto, F
    JOURNAL OF ECT, 2003, 19 (01) : 26 - 30
  • [37] MONITORING CARDIOPULMONARY-RESUSCITATION - ROLE OF BLOOD AND END-TIDAL CARBON-DIOXIDE TENSION
    GASMAN, JD
    FISHMAN, RS
    RAFFIN, TA
    CRITICAL CARE MEDICINE, 1995, 23 (05) : 799 - 800
  • [38] END-TIDAL CARBON-DIOXIDE AS AN INDICATOR OF ARTERIAL CARBON-DIOXIDE IN NEUROINTENSIVE CARE PATIENTS
    RUSSELL, GB
    GRAYBEAL, JM
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1992, 4 (04) : 245 - 249
  • [39] End-tidal carbon dioxide measurement and breathing system filters
    Hardman, JG
    Curran, J
    Mahajan, RP
    ANAESTHESIA, 1997, 52 (07) : 646 - 648
  • [40] SENSITIVITY OF A DISPOSABLE END-TIDAL CARBON-DIOXIDE DETECTOR
    JONES, BR
    DORSEY, MJ
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (03): : 268 - 270