Fracture Resistance of Zirconia Abutments with or without a Titanium Base: An In Vitro Study for Tapered Conical Connection Implants

被引:4
作者
Watanabe, Shota [1 ]
Nakano, Tamaki [1 ]
Ono, Shinji [1 ]
Yamanishi, Yasufumi [1 ]
Matsuoka, Takashi [1 ]
Ishigaki, Shoichi [1 ]
机构
[1] Osaka Univ, Dept Fixed Prosthodont, Sch Dent, 1-8 Yamadaoka, Suita, Osaka 5650871, Japan
基金
日本学术振兴会;
关键词
zirconia abutment; titanium base; tapered conical connection; static load; BONE LEVEL; FOLLOW-UP; LOAD; PERFORMANCE; FAILURE; STRENGTH; CROWNS; WEAR;
D O I
10.3390/ma15010364
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dental implants with tapered conical connections are often combined with zirconia abutments for esthetics; however, the effect of the titanium base on the implant components remains unclear. This study evaluated the effects of a titanium base on the fracture resistance of zirconia abutments and damage to the tapered conical connection implants. Zirconia (Z) and titanium base zirconia (ZT) abutments were fastened to Nobel Biocare (NB) implants and Straumann (ST) implants and subjected to static load testing according to ISO 14801:2016. The experiments were performed with 3 mm of the platform exposed (P3) and no platform exposed (P0). The fracture loads were statistically greater in the titanium base abutments than the zirconia abutments for the NB and ST specimens in the P0 condition. In the P3 condition of the ST specimens, the deformation volume of the ZT group was significantly greater than the Z group. The titanium base increased the fracture resistance of the zirconia abutments. Additionally, the titanium base caused more deformation in the P3 condition. The implant joint design may also affect the amount of damage to the implants when under a load. The mechanical properties of the abutment should be considered when selecting a clinical design.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] An In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thickness: Part I
    Albosefi, Abdalah
    Finkelman, Matthew
    Zandparsa, Roya
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (04): : 296 - 301
  • [22] Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study
    Dogan, Derya Ozdemir
    Gorler, Oguzhan
    Mutaf, Burcu
    Ozcan, Mutlu
    Eyuboglu, Gunes Bulut
    Ulgey, Melih
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 309 - 314
  • [23] Fracture Resistance of Crowns Cemented on Titanium and Zirconia Implant Abutments: A Comparison of Monolithic Versus Manually Veneered All-Ceramic Systems
    Martinez-Rus, Francisco
    Ferreiroa, Alberto
    Oezcan, Mutlu
    Bartolome, Jose F.
    Pradies, Guillermo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (06) : 1448 - 1455
  • [24] In Vitro Fatigue and Fracture Resistance of One- and Two-Piece CAD/CAM Zirconia Implant Abutments
    Gehrke, Peter
    Johannson, Dirk
    Fischer, Carsten
    Stawarczyk, Bogna
    Beuer, Florian
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) : 546 - 554
  • [25] In vitro assessment of the effect of luting agents, abutment height, and fatigue on the retention of zirconia crowns luted to titanium base implant abutments
    Strazzi-Sahyon, Henrico B.
    Bergamo, Edmara T. P.
    Gierthmuehlen, Petra C.
    Lopes, Adolfo C. O.
    Alves, Larissa M. M.
    Jalkh, Ernesto B. Benalcazar
    Zahoui, Abbas
    Coelho, Paulo G.
    de Carvalho, Alexandre M.
    Bonfante, Estevam A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05) : 739.e1 - 739.e8
  • [26] The Impact of Force Transmission on Narrow-Body Dental Implants Made of Commercially Pure Titanium and Titanium Zirconia Alloy with a Conical Implant-Abutment Connection: An Experimental Pilot Study
    Nelson, Katja
    Schmelzeisen, Rainer
    Taylor, Thomas D.
    Zabler, Simon
    Wiest, Wolfram
    Fretwurst, Tobias
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1066 - 1071
  • [27] Stress distribution and microgap formation in angulated zirconia abutments with a titanium base in narrow diameter implants: A 3D finite element analysis
    Zhang, Yuqiang
    Yu, Ping
    Yu, Haiyang
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (07)
  • [28] Importance of Crown Height Ratios in Dental Implants on the Fracture Strength of Different Connection Designs: An In Vitro Study
    Gehrke, Sergio Alexandre
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 790 - 797
  • [29] Mechanical Behavior of Five Different Morse Taper Implants and Abutments with Different Conical Internal Connections and Angles: An In Vitro Experimental Study
    Caballero, Claudia
    Rodriguez, Fernando
    Cortellari, Guillermo Castro
    Scarano, Antonio
    Prados-Frutos, Juan Carlos
    De Aza, Piedad N.
    Fernandes, Gustavo Vicentis Oliveira
    Gehrke, Sergio Alexandre
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (07)
  • [30] Influence of varying titanium base abutment heights on retention of zirconia restorations: An in vitro study
    Nguyen, Olivia
    Lee, Sang J.
    Lee, Jason D.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04) : 604.e1 - 604.e5