Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings

被引:652
作者
Kolandaivelu, Kumaran [1 ,2 ]
Swaminathan, Rajesh [1 ]
Gibson, William J. [1 ]
Kolachalama, Vijaya B. [1 ]
Nguyen-Ehrenreich, Kim-Lien [3 ]
Giddings, Virginia L. [3 ]
Coleman, Leslie [3 ]
Wong, Gee K. [1 ,4 ]
Edelman, Elazer R. [1 ,2 ]
机构
[1] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Div Cardiovasc, Boston, MA 02115 USA
[3] Abbott Vasc, Santa Clara, CA USA
[4] Concord Biomed Sci & Emerging Technol, Lexington, MA USA
基金
美国国家卫生研究院;
关键词
hemodynamics; malapposition; overlapping stents; stents; thrombosis; CORONARY-ARTERY-DISEASE; INTRAVASCULAR ULTRASOUND GUIDANCE; BARE-METAL STENTS; ELUTING STENTS; THROMBOSIS; IMPLANTATION; RESTENOSIS; TRIAL; METAANALYSIS; ANTICOAGULATION;
D O I
10.1161/CIRCULATIONAHA.110.003210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. Methods and Results-We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P=0.011). Thick-strutted (162 mu m) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 mu m) devices in ex vivo flow loops (P<0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries (P=0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matched controls (1.58-fold, P=0.001; and 2.32-fold, P<0.001). The thrombogenicity of polymer-coated stents with thin struts was lowest in all configurations and remained insensitive to incomplete deployment. Computational modeling-based predictions of stent-induced flow derangements correlated with spatial distribution of formed clots. Conclusions-Contrary to popular perception, drug/polymer coatings do not inherently increase acute stent clotting; they reduce thrombosis. However, strut dimensions and positioning relative to the vessel wall are critical factors in modulating stent thrombogenicity. Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment. (Circulation. 2011;123:1400-1409.)
引用
收藏
页码:1400 / 1409
页数:10
相关论文
共 40 条
  • [31] The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents
    Roy, Probal
    Steinberg, Daniel H.
    Sushinsky, Steven J.
    Okabe, Teruo
    Slottow, Tina L. Pinto
    Kaneshige, Kimberly
    Xue, Zhenyi
    Satler, Lowell F.
    Kent, Kenneth M.
    Suddath, William O.
    Pichard, Augusto D.
    Weissman, Neil J.
    Lindsay, Joseph
    Waksman, Ron
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (15) : 1851 - 1857
  • [32] Intracoronary stenting - From concept to custom
    Ruygrok, PN
    Serruys, PW
    [J]. CIRCULATION, 1996, 94 (05) : 882 - 890
  • [33] SAWYER PN, 1972, B NEW YORK ACAD MED, V48, P235
  • [34] High Incidence of Intramural Thrombus After Overlapping Paclitaxel-Eluting Stent Implantation Angioscopic and Histopathologic Analysis in Porcine Coronary Arteries
    Shinke, Toshiro
    Li, Jinsheng
    Chen, Jack P.
    Pendyala, Lakshmana
    Goodchild, Traci
    Jabara, Refat
    Geva, Sarah
    Ueno, Takafumi
    Chronos, Nicolas
    Robinson, Keith
    Hou, Dongming
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (01) : 28 - 35
  • [35] Sprague EA, 2000, J LONG-TERM EFF MED, V10, P111
  • [36] Everolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease.
    Stone, Gregg W.
    Rizvi, Ali
    Newman, William
    Mastali, Kourosh
    Wang, John C.
    Caputo, Ronald
    Doostzadeh, Julie
    Cao, Sherry
    Simonton, Charles A.
    Sudhir, Krishnankutty
    Lansky, Alexandra J.
    Cutlip, Donald E.
    Kereiakes, Dean J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (18) : 1663 - 1674
  • [37] The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography
    Tanigawa, Jun
    Barlis, Peter
    Dimopoulos, Konstantinos
    Dalby, Miles
    Moore, Philip
    Di Mario, Carlo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (02) : 180 - 188
  • [38] Contact activation of blood-plasma coagulation
    Vogler, Erwin A.
    Siedlecki, Christopher A.
    [J]. BIOMATERIALS, 2009, 30 (10) : 1857 - 1869
  • [39] On the mechanisms of biocompatibility
    Williams, David F.
    [J]. BIOMATERIALS, 2008, 29 (20) : 2941 - 2953
  • [40] Late coronary stent thrombosis
    Windecker, Stephan
    Meier, Bernhard