Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings

被引:652
作者
Kolandaivelu, Kumaran [1 ,2 ]
Swaminathan, Rajesh [1 ]
Gibson, William J. [1 ]
Kolachalama, Vijaya B. [1 ]
Nguyen-Ehrenreich, Kim-Lien [3 ]
Giddings, Virginia L. [3 ]
Coleman, Leslie [3 ]
Wong, Gee K. [1 ,4 ]
Edelman, Elazer R. [1 ,2 ]
机构
[1] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Div Cardiovasc, Boston, MA 02115 USA
[3] Abbott Vasc, Santa Clara, CA USA
[4] Concord Biomed Sci & Emerging Technol, Lexington, MA USA
基金
美国国家卫生研究院;
关键词
hemodynamics; malapposition; overlapping stents; stents; thrombosis; CORONARY-ARTERY-DISEASE; INTRAVASCULAR ULTRASOUND GUIDANCE; BARE-METAL STENTS; ELUTING STENTS; THROMBOSIS; IMPLANTATION; RESTENOSIS; TRIAL; METAANALYSIS; ANTICOAGULATION;
D O I
10.1161/CIRCULATIONAHA.110.003210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. Methods and Results-We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P=0.011). Thick-strutted (162 mu m) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 mu m) devices in ex vivo flow loops (P<0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries (P=0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matched controls (1.58-fold, P=0.001; and 2.32-fold, P<0.001). The thrombogenicity of polymer-coated stents with thin struts was lowest in all configurations and remained insensitive to incomplete deployment. Computational modeling-based predictions of stent-induced flow derangements correlated with spatial distribution of formed clots. Conclusions-Contrary to popular perception, drug/polymer coatings do not inherently increase acute stent clotting; they reduce thrombosis. However, strut dimensions and positioning relative to the vessel wall are critical factors in modulating stent thrombogenicity. Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment. (Circulation. 2011;123:1400-1409.)
引用
收藏
页码:1400 / 1409
页数:10
相关论文
共 40 条
  • [1] Clopidogrel withdrawal is associated with proinflammatory and prothrombotic effects in patients with diabetes and coronary artery disease
    Angiolillo, DJ
    Fernandez-Ortiz, A
    Bernardo, E
    Ramírez, C
    Sabaté, M
    Jimenez-Quevedo, P
    Hernández, R
    Moreno, R
    Escaned, J
    Alfonso, F
    Bañuelos, C
    Costa, MA
    Bass, TA
    Macaya, C
    [J]. DIABETES, 2006, 55 (03) : 780 - 784
  • [2] A clinical risk score for prediction of stent thrombosis
    Baran, Kenneth W.
    Lasala, John M.
    Cox, David A.
    Song, Aijun
    Deshpande, Mahesh C.
    Jacoski, Mary V.
    Mascloli, Stephen R.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (05) : 541 - 545
  • [3] A systematic review and meta-analysis on the hazards of discontinuing or not adhering to aspirin among 50 279 patients at risk for coronary artery disease
    Biondi-Zoccai, Giuseppe G. L.
    Lotrionte, Marzia
    Agostoni, Pierfrancesco
    Abbate, Antonio
    Fusaro, Massimiliano
    Burzotta, Francesco
    Testa, Luca
    Sheiban, Imad
    Sangiorgi, Giuseppe
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (22) : 2667 - 2674
  • [4] BRYRNE RA, 2010, J AM COLL CARDIOL, V55
  • [5] 2-Year Clinical and Angiographic Outcomes From a Randomized Trial of Polymer-Free Dual Drug-Eluting Stents Versus Polymer-Based Cypher and Endeavor, Drug-Eluting Stents
    Byrne, Robert A.
    Kastrati, Adnan
    Tiroch, Klaus
    Schulz, Stefanie
    Pache, Juergen
    Pinieck, Susanne
    Massberg, Steffen
    Seyfarth, Melchior
    Laugwitz, Karl-Ludwig
    Birkmeier, Katrin A.
    Schoemig, Albert
    Mehilli, Julinda
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (23) : 2536 - 2543
  • [6] Catheter thrombosis and percutaneous coronary intervention: fundamental perspectives on blood, artificial surfaces and antithrombotic drugs
    Chan, Mark Y.
    Weitz, Jeffrey I.
    Merhi, Yahye
    Harrington, Robert A.
    Becker, Richard C.
    [J]. JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2009, 28 (03) : 366 - 380
  • [7] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    [J]. CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [8] Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro model
    Duraiswamy, Nandini
    Cesar, Jose M.
    Schoephoerster, Richard T.
    Moore, James E., Jr.
    [J]. BIORHEOLOGY, 2008, 45 (05) : 547 - 561
  • [9] Incidence, timing, and correlates of stent thrombosis with the polymeric paclitaxel drug-eluting stent - A TAXUS II, IV, V, and VI meta-analysis of 3,445 patients followed for up to 3 years
    Ellis, Stephen G.
    Colombo, Antonio
    Grube, Eberhard
    Popma, Jeffrey
    Koglin, Joerg
    Dawkins, Keith D.
    Stone, Gregg W.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (10) : 1043 - 1051
  • [10] In vitro analyses of diamond-like carbon coated stents: Reduction of metal ion release, platelet activation, and thrombogenicity
    Gutensohn, K
    Beythien, C
    Bau, J
    Fenner, T
    Grewe, P
    Koester, R
    Padmanaban, K
    Kuehnl, P
    [J]. THROMBOSIS RESEARCH, 2000, 99 (06) : 577 - 585