A case study on experimental and statistical analysis of energy consumption of domestic refrigerator

被引:21
作者
Borikar, Sanjaykumar A. [1 ]
Gupta, Mahendra M. [1 ]
Alazwari, Mashhour A. [2 ]
Malwe, Prateek D. [3 ]
Moustafa, Essam B. [2 ]
Panchal, Hitesh [4 ]
Elsheikh, Ammar [5 ]
机构
[1] Shri Ramdeobaba Coll Engn & Management, Dept Mech Engn, Nagpur 440013, Maharashtra, India
[2] King Abdulaziz Univ, Fac Engn, Mech Engn Dept, Jeddah 21589, Saudi Arabia
[3] Walchand Coll Engn, Dept Mech Engn, Sangli 416415, Maharashtra, India
[4] Govt Engn Coll Patan, Dept Mech Engn, Katpur 384265, Gujarat, India
[5] Tanta Univ, Fac Engn, Prod Engn & Mech Design Dept, Tanta, Egypt
关键词
Experimental analysis; Energy consumption; Analysis of variance; Box-behnken design; Ambient temperature; Heat load; Coefficient of performance; DESIGN; OPTIMIZATION; TEMPERATURE;
D O I
10.1016/j.csite.2021.101636
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the energy consumption analysis of the refrigerator and the effect of the condenser on it. According to the Bureau of Energy Efficiency (BEE), India, the energy efficiency of electric appliances is the key parameter for testing their performance before domestic use. For energy consumption analyses, the experimentation was conducted on the domestic refrigerator (165 L) top-mounted evaporator by retrofitting the refrigerator with an Elliptical Helical Coil Condenser (EHCC) and existing refrigerator with a Straight Tube Condenser (STC). Box-Behnken Design (BBD) is very significant in determining the significant factor and reducing the number of experiments. BBD has been performed to analyze the significance of factors ambient temperature, fresh food compartment temperature and the heat load in energy consumption, and the Coefficient of Performance (COP) of a refrigerator. The heat load and the ambient temperature are both very significant in determining the refrigerator's energy consumption. The most important thing is to increase the liquid content in the charge before it is supplied to the evaporator to extract more amount of heat to increase the cooling effect. The ANOVA (Analysis of Variance) results show that the ambient temperature and the heat load were more significant in increasing energy consumption and decreasing the COP and vice versa. The results of ANOVA and the experiment are very close; the R-2 value 0.995 precisely matches the R-2 adj. value 0.994. The statistical analysis using the Box-Behnken design produces a good fitting of the modeled and experimental data set. The present study aims to examine the effects of said factors and the condenser on the domestic refrigerator's energy consumption and COP. The study exhibits some enhancement in the COP to 2.59 contrary to 2.45 and energy consumption reduced to 1191 Wh from 1755 Wh during the trial of 24 h.
引用
收藏
页数:10
相关论文
共 31 条
  • [1] Introduction
    不详
    [J]. DIABETES CARE, 2015, 38 : S1 - S2
  • [2] [Anonymous], 2020, J MECH ENG SCI, DOI DOI 10.1177/0954406220959097
  • [3] [Anonymous], 2018, COMPUTATIONAL PHYTOC, DOI DOI 10.1016/B978-0-12-812364-5.00003-1
  • [4] Arora, 2015, INT J PHARM PHARM SC, V7, P89
  • [5] Systematic approach to provide building occupants with feedback to reduce energy consumption
    Ashouri, Milad
    Fung, Benjamin C. M.
    Haghighat, Fariborz
    Yoshino, Hiroshi
    [J]. ENERGY, 2020, 194
  • [6] Application of Box Behnken Design to Optimize the Parameters for Kenaf-Epoxy as Noise Absorber
    Aziz, A. R. A.
    Aziz, S. A.
    [J]. INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [7] Baba S.A, 2019, INT J ENG RES TECHNO, V8, P43
  • [8] Babu N. Hari, 2013, INT J ENG RES TECHNO, V2, P1477
  • [9] Box G.E., 1960, Technometrics, V2, P455, DOI [10.1080/00401706.1960.10489912, DOI 10.1080/00401706.1960.10489912]
  • [10] The application of Box-Behnken-Design in the optimization of HPLC separation of fluoroquinolones
    Czyrski, Andrzej
    Sznura, Justyna
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)