The results of the in situ measurement of the emissivity distribution of catalyst tubes in a large petrochemical reformer are presented. Knowledge of this distribution is fundamental to accurate temperature measurement through radiation thermometry, particularly in the presence of large reflection errors. It is shown how the uncertainty in emissivity propagates to the uncertainty in temperature, and that in many cases the contribution of the emissivity uncertainty dominates the total uncertainty. A novel type of reflectometer based on a solid integrating sphere was developed to perform the emissivity measurements. A description of this instrument is also given.
引用
收藏
页码:622 / 626
页数:5
相关论文
共 2 条
  • [1] Spectral emissivity and transmissivity measurement for zinc sulphide infrared window based on integrating-sphere reflectometry
    Zhang, Yu-Feng
    Dai, Jing-Min
    Zhang, Lei
    Pan, Wei-Dong
    OPTICAL ENGINEERING, 2013, 52 (08)
  • [2] INTERCOMPARISON OF TWO COLLECTION GEOMETRIES IN TOTAL LUMINOUS FLUX OF STRAIGHT TUBE TYPE LAMP MEASUREMENT: THE INTEGRATING SPHERE AND THE INTEGRATING HEMISPHERE
    Oshima, K.
    Ohkubo, K.
    Mishima, S.
    Kubo, H.
    Huang, H.
    PROCEEDINGS OF CIE 2012 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2012, : 663 - 667