Fabrication of High-Density Out-of-Plane Microneedle Arrays with Various Heights and Diverse Cross-Sectional Shapes

被引:60
作者
Roh, Hyeonhee [1 ,2 ]
Yoon, Young Jun [1 ]
Park, Jin Soo [1 ,2 ]
Kang, Dong-Hyun [3 ]
Kwak, Seung Min [3 ]
Lee, Byung Chul [1 ]
Im, Maesoon [1 ,4 ]
机构
[1] Korea Inst Sci & Technol KIST, Brain Sci Inst, Seoul 02792, South Korea
[2] Korea Univ, Div Elect Engn, Coll Engn, Seoul 02841, South Korea
[3] KIST, Micro Nano Fabricat Ctr, Seoul 02792, South Korea
[4] Univ Sci & Technol UST, KIST Sch, Div Biomed Sci & Technol, Seoul 02792, South Korea
基金
新加坡国家研究基金会;
关键词
Microneedle; Various heights; Cross-sectional shapes; Isotropic etch; Deep reactive ion etching; ELECTRODES; MECHANICS; RESPONSES; INSERTION; DEVICE; TISSUE; CUFF;
D O I
10.1007/s40820-021-00778-1
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Out-of-plane microneedle structures are widely used in various applications such as transcutaneous drug delivery and neural signal recording for brain machine interface. This work presents a novel but simple method to fabricate high-density silicon (Si) microneedle arrays with various heights and diverse cross-sectional shapes depending on photomask pattern designs. The proposed fabrication method is composed of a single photolithography and two subsequent deep reactive ion etching (DRIE) steps. First, a photoresist layer was patterned on a Si substrate to define areas to be etched, which will eventually determine the final location and shape of each individual microneedle. Then, the 1st DRIE step created deep trenches with a highly anisotropic etching of the Si substrate. Subsequently, the photoresist was removed for more isotropic etching; the 2nd DRIE isolated and sharpened microneedles from the predefined trench structures. Depending on diverse photomask designs, the 2nd DRIE formed arrays of microneedles that have various height distributions, as well as diverse cross-sectional shapes across the substrate. With these simple steps, high-aspect ratio microneedles were created in the high density of up to 625 microneedles mm(-2) on a Si wafer. Insertion tests showed a small force as low as similar to 172 mu N/microneedle is required for microneedle arrays to penetrate the dura mater of a mouse brain. To demonstrate a feasibility of drug delivery application, we also implemented silk microneedle arrays using molding processes. The fabrication method of the present study is expected to be broadly applicable to create microneedle structures for drug delivery, neuroprosthetic devices, and so on.
引用
收藏
页数:19
相关论文
共 70 条
[1]   Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis [J].
Aoyagi, Seiji ;
Izumi, Hayato ;
Fukuda, Mitsuo .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (01) :20-28
[2]  
Aoyagi S, 2020, J ROBOT MECHATRON, V32, P371
[3]   Snake fang-inspired stamping patch for transdermal delivery of liquid formulations [J].
Bae, Won-Gyu ;
Ko, Hangil ;
So, Jin-Young ;
Yi, Hoon ;
Lee, Chan-Ho ;
Lee, Dong-Hun ;
Ahn, Yujin ;
Lee, Sang-Hyeon ;
Lee, Kyunghun ;
Jun, Joonha ;
Kim, Hyoung-Ho ;
Jeon, Noo Li ;
Jung, Woonggyu ;
Song, Chang-Seon ;
Kim, Taesung ;
Kim, Yeu-Chun ;
Jeong, Hoon Eui .
SCIENCE TRANSLATIONAL MEDICINE, 2019, 11 (503)
[4]   A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses [J].
Bhandari, R. ;
Negi, S. ;
Rieth, L. ;
Normann, R. A. ;
Solzbacher, F. .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 145 :123-130
[5]   A wafer-scale etching technique for high aspect ratio implantable MEMS structures [J].
Bhandari, R. ;
Negi, S. ;
Rieth, L. ;
Solzbacher, F. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 162 (01) :130-136
[6]   Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion [J].
Bjornsson, C. S. ;
Oh, S. J. ;
Al-Kofahi, Y. A. ;
Lim, Y. J. ;
Smith, K. L. ;
Turner, J. N. ;
De, S. ;
Roysam, B. ;
Shain, W. ;
Kim, S. J. .
JOURNAL OF NEURAL ENGINEERING, 2006, 3 (03) :196-207
[7]   Selectivity of direct and network-mediated stimulation of the retinal ganglion cells with epi-, sub- and intraretinal electrodes [J].
Boinagrov, David ;
Pangratz-Fuehrer, Susanne ;
Goetz, Georges ;
Palanker, Daniel .
JOURNAL OF NEURAL ENGINEERING, 2014, 11 (02)
[8]   Microneedles integrated with a triboelectric nanogenerator: an electrically active drug delivery system [J].
Bok, Moonjeong ;
Lee, Yunwoo ;
Park, Daehoon ;
Shin, Sangho ;
Zhao, Zhi-Jun ;
Hwang, Boyeon ;
Hwang, Soon Hyoung ;
Jeon, So Hee ;
Jung, Joo-Yun ;
Park, Sung Ha ;
Nah, Junghyo ;
Lim, Eunju ;
Jeong, Jun-Ho .
NANOSCALE, 2018, 10 (28) :13502-13510
[9]   Hollow silicon microneedle fabrication using advanced plasma etch technologies for applications in transdermal drug delivery [J].
Bolton, Chris J. W. ;
Howells, Olivia ;
Blayney, Gareth J. ;
Eng, Pey F. ;
Birchall, James C. ;
Gualeni, Benedetta ;
Roberts, Kerry ;
Ashraf, Huma ;
Guy, Owen J. .
LAB ON A CHIP, 2020, 20 (15) :2788-2795
[10]  
Boonma A., 2013, Computer-Aided Design and Applications, V10, P139, DOI DOI 10.3722/CADAPS.2013.139-157