Fissure Integrity and Volume Reduction in Emphysema: A Retrospective Study

被引:14
作者
de Oliveira, Hugo Goulart [1 ,2 ]
de Oliveira, Silvia Martins [1 ]
Rambo, Rafael Ramos [2 ]
de Macedo Neto, Amarilio Vieira [1 ,2 ]
机构
[1] HMV, Rua Ramiro Barcelos 910,Suite 203, BR-90035001 Porto Alegre, RS, Brazil
[2] HCPA, Porto Alegre, RS, Brazil
关键词
Emphysema; Chronic obstructive pulmonary disease; Bronchoscopy; bronchoscopic lung volume reduction; COLLATERAL VENTILATION; FOLLOW-UP; EXERCISE; VALVES; ATELECTASIS; COPD;
D O I
10.1159/000446288
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: One-way endobronchial valves (EBVs) relieve symptoms of emphysema, particularly in patients without collateral ventilation between the target and adjacent lobes. Pretreatment knowledge of fissure integrity could serve as an aid in indicating EBV interventions. Objective: This study aimed to investigate the relationship between software-measured lung fissure integrity and clinically relevant lung volume reduction (>= 350 ml) in emphysema patients treated with one-way EBVs using a lobar exclusion strategy. Methods: Of 108 patients treated between March 2008 and July 2014, 38 had both baseline and follow-up computed tomography (CT) scans acquired following a specific protocol for quantitative CT analysis and were included in the study (total of 39 treatments, two lungs treated in 1 patient). Outcome measures were fissure integrity measured on baseline CT scans, difference between pre- and postoperative lung volume (considering the lowest measured postoperative volume), and correlation between fissure integrity and volume change. Results: Fissure integrity >= 75% correlated with volume reduction >= 350 ml (Spearman coefficient: -0.65; p < 0.01). The mean and median volume reductions were 1,223.96 +/- 907.5 ml and 663 ml, respectively, for lungs with fissure integrity >= 75% (n = 31). The accuracy of fissure integrity >= 75% in predicting a volume reduction was 87.2%. The positive predictive value of fissure integrity >= 75% to predict a volume reduction >= 350 ml was 83.9%, and it was 70% for fissure integrity 75-90% and 90.5% for fissure integrity >90%. Conclusions: A target lobe volume reduction using EBVs is possible with lung fissure integrity >= 75%. For patients with fissure integrity between 75 and 90%, a further evaluation of interlobar ventilation should be performed. A clinically relevant volume reduction following treatment with EBVs is likely with any level of fissure integrity >90%. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:471 / 479
页数:9
相关论文
共 31 条
[11]   Predicting Atelectasis by Assessment of Collateral Ventilation prior to Endobronchial Lung Volume Reduction: A Feasibility Study [J].
Gompelmann, D. ;
Eberhardt, R. ;
Michaud, G. ;
Ernst, A. ;
Herth, F. J. F. .
RESPIRATION, 2010, 80 (05) :419-425
[12]   Radiological and clinical outcomes of using Chartis™ to plan endobronchial valve treatment [J].
Herth, Felix J. F. ;
Eberhardt, Ralf ;
Gompelmann, Daniela ;
Ficker, Joachim H. ;
Wagner, Manfred ;
Ek, Lars ;
Schmidt, Bernd ;
Slebos, Dirk-Jan .
EUROPEAN RESPIRATORY JOURNAL, 2013, 41 (02) :302-308
[13]   Efficacy predictors of lung volume reduction with Zephyr valves in a European cohort [J].
Herth, Felix J. F. ;
Noppen, Marc ;
Valipour, Arschang ;
Leroy, Sylvie ;
Vergnon, Jean-Michel ;
Ficker, Joachim H. ;
Egan, Jim J. ;
Gasparini, Stefano ;
Agusti, Carlos ;
Holmes-Higgin, Debby ;
Ernst, Armin .
EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (06) :1334-1342
[14]   Outcomes of Endobronchial Valve Treatment Based on the Precise Criteria of an Endobronchial Catheter for Detection of Collateral Ventilation under Spontaneous Breathing [J].
Herzog, Dominik ;
Thomsen, Christian ;
Poellinger, Alexander ;
Doellinger, Felix ;
Schreiter, Nils ;
Froeling, Vera ;
Schuermann, Dirk ;
Temmesfeld-Wollbruck, Bettina ;
Hippenstiel, Stefan ;
Suttorp, Norbert ;
Huebner, Ralf-Harto .
RESPIRATION, 2016, 91 (01) :69-78
[15]   Atelectasis and survival after bronchoscopic lung volume reduction for COPD [J].
Hopkinson, N. S. ;
Kemp, S. V. ;
Toma, T. P. ;
Hansell, D. M. ;
Geddes, D. M. ;
Shah, P. L. ;
Polkey, M. I. .
EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (06) :1346-1351
[16]   Bronchoscopic lung volume reduction: indications, effects and prospects [J].
Hopkinson, Nicholas S. .
CURRENT OPINION IN PULMONARY MEDICINE, 2007, 13 (02) :125-130
[17]   Effect of Bronchoscopic lung volume reduction on dynamic hyperinflation and exercise in emphysema [J].
Hopkinson, NS ;
Toma, TP ;
Hansell, DM ;
Goldstraw, P ;
Moxharn, J ;
Geddes, DM ;
Polkey, MI .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (05) :453-460
[18]  
Ingenito Edward P, 2008, Proc Am Thorac Soc, V5, P454, DOI 10.1513/pats.200707-085ET
[19]   Time for the Global Rollout of Endoscopic Lung Volume Reduction [J].
Koegelenberg, Coenraad F. N. ;
Slebos, Dirk-Jan ;
Shah, Pallav L. ;
Theron, Johan ;
Dheda, Keertan ;
Allwood, Brian W. ;
Herth, Felix J. F. .
RESPIRATION, 2015, 90 (05) :430-440
[20]   Effect of fissure integrity on lung volume reduction using a polymer sealant* in advanced emphysema [J].
Magnussen, Helgo ;
Kramer, Mordechai R. ;
Kirsten, Anne-Marie ;
Marquette, Charles ;
Valipour, Arschang ;
Stanzel, Franz ;
Bonnet, Reiner ;
Behr, Juergen ;
Fruchter, Oren ;
Refaely, Yael ;
Eberhardt, Ralf ;
Herth, Felix J. F. .
THORAX, 2012, 67 (04) :302-308