Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography

被引:25
作者
Reis, Alexandre S. C. [1 ]
Zangalli, Camila E. S. [1 ]
Abe, Ricardo Y. [1 ]
Silva, Andre L. [1 ]
Vianna, Jayme R. [2 ]
Vasconcellos, Jose Paulo C. [1 ]
Costa, Vital P. [1 ]
机构
[1] Univ Estadual Campinas, Dept Ophthalmol, Campinas, SP, Brazil
[2] Dalhousie Univ, Dept Ophthalmol & Visual Sci, Halifax, NS, Canada
关键词
glaucoma; neuroretinal rim; optic nerve head; optical coherence tomography; reproducibility; NERVE-FIBER LAYER; DISC MARGIN ANATOMY; OPEN-ANGLE GLAUCOMA; NEURORETINAL RIM; THICKNESS MEASUREMENTS; AUTOMATED SEGMENTATION; DIAGNOSTIC-ACCURACY; HEAD MEASUREMENTS; NORMAL EYES; FIELD LOSS;
D O I
10.1111/aos.13464
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the reproducibility of Bruch's membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) measurements using spectral domain optical coherence tomography (SD-OCT). Additionally, to investigate the reproducibility of BMO area measurements and fovea to BMO centre (FoBMO) angle. Methods: Participants were healthy subjects (n=30) and patients with glaucoma (n=26). One eye of each participant was scanned to obtain optic nerve head (24 radial B-scans) and peripapillary (one circular B-scan) images by three independent examiners. Additionally, one examiner imaged each participant three times on the same day. Intra- and interobserver reproducibilities were estimated by within-subject standard deviation (SW) and coefficient of variation (COV). Spearman's rank correlation coefficient was used to test the correlation between the magnitude of the parameter and its standard deviation. Results: The global BMO-MRW COVs (%) in healthy/glaucoma subjects were 0.87/1.34 and 1.28/3.13 for intra- and interobserver analyses, respectively, and the corresponding global RNFLT figures were 1.50/2.10 and 2.04/2.87. Global mean BMO-MRW and RNFLT showed no correlation with their respective standard deviations. The reproducibilities of BMO area and FoBMO angle were excellent and similar between the groups. Conclusion: The reproducibilities of BMO-MRW, BMO area measurements and FoBMO angle were excellent in both healthy subjects and patients with glaucoma. Bruch's membrane opening minimum rim width (BMO-MRW) reproducibility is comparable to that of RNFLT measurements.
引用
收藏
页码:E548 / E555
页数:8
相关论文
共 42 条
[1]   Automated Segmentation of Optic Nerve Head Structures With Optical Coherence Tomography [J].
Almobarak, Faisal A. ;
O'Leary, Neil ;
Reis, Alexandre S. C. ;
Sharpe, Glen P. ;
Hutchison, Donna M. ;
Nicolela, Marcelo T. ;
Chauhan, Balwantray C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (02) :1161-1168
[2]   Reproducibility of Optical Coherence Tomography Measurements in Children [J].
Altemir, Irene ;
Pueyo, Victoria ;
Elia, Noemi ;
Polo, Vicente ;
Larrosa, Jose M. ;
Oros, Daniel .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (01) :171-176
[3]   Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT [J].
Arthur, S. N. ;
Smith, S. D. ;
Wright, M. M. ;
Grajewski, A. L. ;
Wang, Q. ;
Terry, J. M. ;
Lee, M. S. .
EYE, 2011, 25 (02) :192-200
[4]  
Bland JM, 1996, BRIT MED J, V313, P744
[5]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[6]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[7]   Reproducibility and Repeatability of Cirrus™ HD-OCT Peripapillary Retinal Nerve Fibre Layer Thickness Measurements in Young Normal Subjects [J].
Carpineto, Paolo ;
Nubile, Mario ;
Agnifili, Luca ;
Toto, Lisa ;
Aharrh-Gnama, Agbeanda ;
Mastropasqua, Rodolfo ;
Di Antonio, Luca ;
Fasanella, Vincenzo ;
Mastropasqua, Alessandra .
OPHTHALMOLOGICA, 2012, 227 (03) :139-145
[8]   Sensitivity and Specificity of Time-Domain versus Spectral-Domain Optical Coherence Tomography in Diagnosing Early to Moderate Glaucoma [J].
Chang, Robert T. ;
Knight, O'Rese J. ;
Feuer, William J. ;
Budenz, Donald L. .
OPHTHALMOLOGY, 2009, 116 (12) :2294-2299
[9]   Bruch's Membrane Opening Minimum Rim Width and Retinal Nerve Fiber Layer Thickness in a Normal White Population A Multicenter Study [J].
Chauhan, Balwantray C. ;
Danthurebandara, Vishva M. ;
Sharpe, Glen P. ;
Demirel, Shaban ;
Girkin, Christopher A. ;
Mardin, Christian Y. ;
Scheuerle, Alexander F. ;
Burgoyne, Claude F. .
OPHTHALMOLOGY, 2015, 122 (09) :1786-1794
[10]   From Clinical Examination of the Optic Disc to Clinical Assessment of the Optic Nerve Head: A Paradigm Change [J].
Chauhan, Balwantray C. ;
Burgoyne, Claude F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) :218-227