In-vitro intra- and inter-inhaler flow rate-dependent dosage emission from a combination of budesonide and eformoterol in a dry powder inhaler

被引:50
|
作者
Tarsin, W [1 ]
Assi, KH [1 ]
Chrystyn, H [1 ]
机构
[1] Univ Bradford, Sch Pharm, Bradford BD7 1DP, W Yorkshire, England
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2004年 / 17卷 / 01期
关键词
emitted dose; inhalation rate; variability; budesonide; eformoterol;
D O I
10.1089/089426804322994433
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Some dry powder inhalers have profound inhalation flow rate-dependent dosage emission, and it has been suggested that there are links between the in vitro emitted dose, total lung deposition, and subsequent clinical response. We have measured the in vitro dosage delivery for a combination of budesonide and eformoterol in a new version of the Turbuhaler. At inhalation flow rates of 30, 60, and 90 Lmin(-1), the total dose emission for 10 separate inhalations from each of six inhalers was determined. The aerodynamic characteristics of the emitted dose using inhalation flow rates of 28.3 and 60 Lmin(-1) were measured using the Andersen Cascade Impactor. The mean (SD) emitted dose for budesonide, at 30, 60, and 90 Lmin(-1), was 37.5%(18.2%), 64.4%(16.6%), and 107.4%(36.0%) (of the nominal emitted dose), respectively, and for eformoterol were 38.0%(20.3%), 65.0%(16.8%), and 104.9%(36.2%) (of the nominal emitted dose), respectively. Variability of dose emission characteristics from each inhaler and between inhalers at each flow rate was found. The aerodynamic particle size characterization of the emitted dose at flow rates of 28.3 and 60 Lmin(-1) revealed a mean fine particle dose for budesonide of 11.9% and 28.6% of the nominal emitted dose, respectively, and similarly 10.0% and 26.3% for eformoterol. At 28.3 Lmin(-1), the majority of the emitted dose (54.8% for budesonide and 64.5% for eformoterol) was deposited in the throat and preseparator of the Andersen Cascade Impactor. The mass median aerodynamic diameters for budesonide and eformoterol at 28.3 Lmin(-1) were 3.2 and 3.6 mu m, respectively, and similarly at 60 Lmin(-1) were 2.4 and 2.5 mu m. The modified Turbuhaler containing a budesonide and eformoterol combined formulation shows intra- and inter-inhaler flow-dependent dosage emission. The clinical significance of the in vitro dose-dependent properties should be investigated.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 1 条
  • [1] Effect of maximum inhalation flow and inhaled volume on formoterol drug deposition in-vitro from an Easyhaler® dry powder inhaler
    Abadelah, Mohamad
    Hazim, Firisteh
    Chrystyn, Henry
    Bagherisadeghi, Golshan
    Rahmoune, Hassan
    Larhrib, Hassan
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 104 : 180 - 187