The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery

被引:7
作者
Noora, J
Lamy, A
Smith, KM
Kent, R
Batt, D
Fedoryshyn, J
Wang, XY
机构
[1] McMaster Univ, Hamilton, ON, Canada
[2] Hamilton Hlth Sci, Hamilton, ON, Canada
[3] CADENCE Res Grp, Hamilton, ON, Canada
来源
PERFUSION-UK | 2003年 / 18卷 / 05期
关键词
D O I
10.1191/0267659103pf681oa
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Open-heart surgery (OHS) requires cardiopulmonary bypass (CPB) in most patients. Membrane oxygenators are a critical component of the CPB system. Despite advancements in CPB technology, injury to blood components during CPB still occurs and may result in complications after surgery. The purpose of the present study was to evaluate the performance of the Medtronic Affinity NT(R) with Trillium coating and the Cobe Optima XP(R) oxygenators and compare their influence on blood components. Two hundred and fifty-six male and female patients scheduled for urgent or elective cardiac surgery with CPB were randomly assigned to either the Affinity NT or the Optima XP oxygenators. Outcomes included platelets, hemoglobin, leukocyte counts, and O-2 transfer, measured preoperatively and at 15, 45 and 75 min of CPB time. Blood loss was measured at six and 12 hours postoperatively. A modified intention-to-treat analysis was conducted. The two groups were similar for age, sex, height, weight, body surface area, and blood components at baseline. There were no differences between the Affinity NT and Optima XP for any outcome measure, although a significant change with time was seen in platelets, hemoglobin, hematocrit and leukocytes, as well as O-2 transfer for both groups (p<0.001). The Affinity NT oxygenator had a significantly lower difference in pressure across the membrane (p<0.001) compared with the Optima XP. In conclusion, the two oxygenators performed similarly with respect to their impact on blood components, O-2 transfer, and blood loss postoperatively during OHS with CPB. The Affinity NT had the smaller transmembrane pressure drop of the two.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 30 条
  • [1] PLATELETS AND EXTRACORPOREAL-CIRCULATION
    ADDONIZIO, VP
    COLMAN, RW
    [J]. BIOMATERIALS, 1982, 3 (01) : 9 - 15
  • [2] PRESERVATION OF HUMAN PLATELETS WITH PROSTAGLANDIN-E1 DURING INVITRO SIMULATION OF CARDIOPULMONARY BYPASS
    ADDONIZIO, VP
    MACARAK, EJ
    NIEWIAROWSKI, S
    COLMAN, RW
    EDMUNDS, LH
    [J]. CIRCULATION RESEARCH, 1979, 44 (03) : 350 - 357
  • [3] BEARSS MG, 1996, AMSECT TODAY JUN, P21
  • [4] BOONSTRA PW, 1994, J THORAC CARDIOV SUR, V107, P289
  • [5] INFLAMMATORY RESPONSE TO CARDIOPULMONARY BYPASS
    BUTLER, J
    ROCKER, GM
    WESTABY, S
    [J]. ANNALS OF THORACIC SURGERY, 1993, 55 (02) : 552 - 559
  • [6] PLATELET AND NEUTROPHIL ACTIVATION IN CARDIOPULMONARY BYPASS
    COLMAN, RW
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (01) : 32 - 34
  • [7] Dickinson Timothy, 2002, J Extra Corpor Technol, V34, P248
  • [8] Changes of leukocyte subsets in coronary artery bypass surgery:: Cardiopulmonary bypass versus 'off-pump' techniques
    Diegeler, A
    Tárnok, A
    Rauch, T
    Haberer, D
    Falk, V
    Battellini, R
    Autschbach, R
    Hambsch, J
    Schneider, P
    Mohr, FW
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (06) : 327 - 332
  • [9] The incidence and cause of emergency oxygenator changeovers
    Fisher, AR
    [J]. PERFUSION-UK, 1999, 14 (03): : 207 - 212
  • [10] Modeling flow effects on thrombotic deposition in a membrane oxygenator
    Gartner, MJ
    Wilhelm, CR
    Gage, KL
    Fabrizio, MC
    Wagner, WR
    [J]. ARTIFICIAL ORGANS, 2000, 24 (01) : 29 - 36