Optical Waveguide Biosensor Based on Cascaded Mach-Zehnder Interferometer and Ring Resonator with Vernier Effect

被引:3
|
作者
Jiang, Xianxin [1 ]
Tang, Longhua [1 ]
Song, Jinyan [1 ]
Li, Mingyu [1 ]
He, Jian-Jun [1 ]
机构
[1] Zhejiang Univ, Ctr Integrated Optoelect, Dept Opt Engn, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
关键词
Optical waveguide sensor; microring; Mach-Zehnder interferometer; Vernier effect; SILICON; SENSORS;
D O I
10.1117/12.2077943
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Optical waveguide biosensors based on silicon-on-insulator (SOI) have been extensively investigated owing to its various advantages and many potential applications. In this article, we demonstrate a novel highly sensitive biosensor based on cascaded Mach-Zehnder interferometer (MZI) and ring resonator with the Vernier effect using wavelength interrogation. The experimental results show that the sensitivity reached 1,960 nm/RIU and 19,100 nm/RIU for sensors based on MZI alone and cascaded MZI-ring with Vernier effect, respectively. A biosensing application was also demonstrated by monitoring the interaction between goat and antigoat immunoglobulin G (IgG) pairs. This integrated high sensitivity biosensor has great potential for medical diagnostic applications.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Cascaded Mach-Zehnder interferometer tunable filters
    Ovvyan, A. P.
    Gruhler, N.
    Ferrari, S.
    Pernice, W. H. P.
    JOURNAL OF OPTICS, 2016, 18 (06)
  • [32] Design of compact ring resonator and Mach-Zehnder interferometer with air trenches
    Kim, S
    Jiang, JH
    Nordin, GP
    OPTICAL ENGINEERING, 2006, 45 (05)
  • [33] Optical fiber temperature sensor with Vernier effect formed by Mach-Zehnder interferometer cascaded Sagnac interferometer based on Hollow-core photonic crystal fiber
    Su, Hang
    Gao, Laixu
    Zhang, Zhaorong
    Kong, Fanxin
    Dong, Zhen
    Zhao, Chunlong
    Xiao, Dehang
    Liu, Chunyu
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2022, 52
  • [34] Improved Sensitivity of Microring Resonator-Loaded Mach-Zehnder Interferometer Biosensor
    Yoshida, Soichiro
    Ishihara, Shintaro
    Nishijima, Yoshiaki
    Kokubun, Yasuo
    Arakawa, Taro
    SENSORS AND MATERIALS, 2017, 29 (09) : 1241 - 1246
  • [35] Improved Mach-Zehnder Interferometer with Micro-Ring-Resonator-Based Two-Beam Interferometer
    Wang, Fan
    Wang, Xiang
    Xiao, Simiao
    Yu, Hui
    Hao, Yinlei
    Jiang, Xiaoqing
    Wang, Minghua
    Yang, Jianyi
    2009 IEEE/LEOS WINTER TOPICALS MEETING SERIES (WTM 2009), 2009, : 94 - 95
  • [36] A Mach-Zehnder interferometer based on silicon oxides for biosensor applications
    Hong, Jongin
    Choi, Jung Sung
    Han, Gayoung
    Kang, Jae Kwang
    Kim, Chang-Min
    Kim, Tae Song
    Yoon, Dae Sung
    ANALYTICA CHIMICA ACTA, 2006, 573 : 97 - 103
  • [37] Temperature sensitivity of waveguide Mach-Zehnder interferometer
    Dullo, Firehun Tsige
    Sokolov, Viktor
    Chauvet, Cyprien
    Lindecrantz, Susan
    Solbo, Stian Andre
    Helleso, Olav Gaute
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES XVIII, 2014, 8988
  • [38] Biosensor based on plasmonic Mach-Zehnder interferometer with metallic gratings
    Wang Kun
    Duan Gao-Yan
    Lang Pei-Lin
    Zhao Yu-Fang
    Liu Jian-Bin
    Song Gang
    ACTA PHYSICA SINICA, 2022, 71 (01)
  • [39] Wavelength-Selective Optical Waveguide Isolator Based on Nonreciprocal Ring-Coupled Mach-Zehnder Interferometer
    Zhou, Haifeng
    Jiang, Xiaoqing
    Yang, Jianyi
    Zhou, Qiang
    Yu, Tianbao
    Wang, Minghua
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2008, 26 (17-20) : 3166 - 3172
  • [40] Mach-Zehnder interferometer employing coupled-resonator optical waveguides
    Martinez, A
    Griol, A
    Sanchis, P
    Marti, J
    OPTICS LETTERS, 2003, 28 (06) : 405 - 407