The application of optical coherence tomography to problems in polymer matrix composites

被引:63
|
作者
Dunkers, JP [1 ]
Phelan, FR
Sanders, DP
Everett, MJ
Green, WH
Hunston, DL
Parnas, RS
机构
[1] Natl Inst Stand & Technol, Polymer Composites Grp, Gaithersburg, MD 20899 USA
[2] Univ Calif Lawrence Livermore Natl Lab, Med Technol Program, Livermore, CA USA
[3] USA, Res Lab, Weap & Mat Res Directorate, Aberdeen Proving Ground, MD USA
关键词
optical coherence tomography; composites; microstructure; permeability; damage; imaging;
D O I
10.1016/S0143-8166(01)00010-0
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Composites Group at the National Institute of Standards and Technology has found optical coherence tomography (OCT) to be a powerful tool for non-destructive characterization of polymer matrix composites. Composites often exhibit superior properties to traditional materials such as wood and metal. However, the barrier to their widespread infiltration into consumer markets is cost. Composites can be made more cost competitive by improved composite design, process optimization, and quality control. OCT provides a means of evaluating the three aforementioned areas. OCT is a very versatile technique that can be applied to a variety of problems in polymer composites such as: microstructure determination for permeability and mechanical property prediction, void, dry spot, and defect detection, and damage evaluation. Briefly, OCT uses a low coherence source such as a superluminescent diode laser with a fiber optic based Michelson interferometer, Tn this configuration, the composite is the fixed arm of the interferometer. Reflections from heterogeneities within the sample are mapped as a function of thickness for any one position. Volume information is generated by translating the sample on a motorized stage. Information about the location and size of a feature within the composite is obtained. In this work, the power of OCT for imaging composite microstructure and damage is presented. An example of permeability prediction using the composite microstructure imaged from OCT is demonstrated. The effect of image processing on the value of permeability is discussed. Using the same sample, OCT imaging of composite impact damage is compared to more traditional techniques, X-ray computed tomography and confocal microscopy. Published by Elsevier Science Ltd.
引用
收藏
页码:135 / 147
页数:13
相关论文
共 50 条
  • [21] Application of optical coherence tomography for functional film imaging
    Shin, Yongjin
    Kwak, Wooseop
    Choi, Eun See
    Kim, Youngseop
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 : S62 - S66
  • [22] Application of anterior segment optical coherence tomography in glaucoma
    Sharma, Reetika
    Sharma, Ajay
    Arora, Tarun
    Sharma, Sourabh
    Sobti, Amit
    Jha, Bhaskar
    Chaturvedi, Neha
    Dada, Tanuj
    SURVEY OF OPHTHALMOLOGY, 2014, 59 (03) : 311 - 327
  • [23] Methods and application areas of endoscopic optical coherence tomography
    Yaqoob, Zahid
    Wu, Jigang
    McDowell, Emily J.
    Heng, Xin
    Yang, Changhuei
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)
  • [24] An application of optical coherence tomography and a smart polymer gel to construct an enzyme-free sugar sensor
    Sirirat Ouiganon
    Chongdee Thammakhet
    Panote Thavarungkul
    Proespichaya Kanatharana
    Chittanon Buranachai
    Applied Physics B, 2016, 122
  • [25] An application of optical coherence tomography and a smart polymer gel to construct an enzyme-free sugar sensor
    Ouiganon, Sirirat
    Thammakhet, Chongdee
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Buranachai, Chittanon
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (06):
  • [26] Retinal applications of swept source optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA)
    Lains, Ines
    Wang, Jay C.
    Cui, Ying
    Katz, Raviv
    Vingopoulos, Filippos
    Staurenghi, Giovanni
    Vavvas, Demetrios G.
    Miller, Joan W.
    Miller, John B.
    PROGRESS IN RETINAL AND EYE RESEARCH, 2021, 84
  • [27] Optical Coherence Tomography and Optical Coherence Tomography Angiography in Neglected Diseases
    Mahendradas, Padmamalini
    Acharya, Isha
    Rana, Vipin
    Bansal, Reema
    Ben Amor, Hager
    Khairallah, Moncef
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2024, 32 (07) : 1427 - 1434
  • [28] Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract
    Osiac, Eugen
    Saftoiu, Adrian
    Gheonea, Dan Ionut
    Mandrila, Ion
    Angelescu, Radu
    WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (01) : 15 - 20
  • [29] Optical coherence tomography and optical coherence tomography angiography in uveitis: A review
    Invernizzi, Alessandro
    Cozzi, Mariano
    Staurenghi, Giovanni
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 (03) : 357 - 371
  • [30] Optical coherence tomography and Doppler optical coherence tomography in the gastrointestinal tract
    Eugen Osiac
    Adrian Sǎftoiu
    Dan Ionut Gheonea
    Ion Mandrila
    Radu Angelescu
    World Journal of Gastroenterology, 2011, 17 (01) : 15 - 20