Imaging the cardiovascular system: Seeing is believing

被引:9
作者
Borg, TK [1 ]
Stewart, JA
Sutton, MA
机构
[1] Univ S Carolina, Dept Cell & Dev Biol & Anat, Columbia, SC 29208 USA
[2] Univ S Carolina, Dept Engn Mech, Columbia, SC 29208 USA
关键词
microscopy; cardiovascular; ultrasound; confocal microscopy;
D O I
10.1017/S1431927605050439
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
From the basic light microscope through high-end imaging systems such as multiphoton confocal microscopy and electron microscopes, microscopy has been and will continue to be an essential tool in developing an understanding of cardiovascular development, function, and disease. In this review we briefly touch on a number of studies that illustrate the importance of these forms of microscopy in studying cardiovascular biology. We also briefly review a number of imaging modalities such as computed tomography, (CT) Magnetic resonance imaging (MRI), ultrasound, and positron emission tomography (PET) that, although they do not fall under the realm of microscopy, are imaging modalities that greatly complement microscopy. Finally we examine the role of proper imaging system calibration and the potential importance of calibration in understanding biological tissues, such as the cardiovascular system, that continually undergo deformation in response to strain.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 82 条
[1]   Automated tracing and change analysis of angiogenic vasculature from in vivo multiphoton confocal image time series [J].
Abdul-Karim, MA ;
Al-Kofahi, K ;
Brown, EB ;
Jain, RK ;
Roysam, B .
MICROVASCULAR RESEARCH, 2003, 66 (02) :113-125
[2]   Noninvasive imaging of quantum dots in mice [J].
Ballou, B ;
Lagerholm, BC ;
Ernst, LA ;
Bruchez, MP ;
Waggoner, AS .
BIOCONJUGATE CHEMISTRY, 2004, 15 (01) :79-86
[3]   Increased association of ZO-1 with connexin43 during remodeling of cardiac gap junctions [J].
Barker, RJ ;
Price, RL ;
Gourdie, RG .
CIRCULATION RESEARCH, 2002, 90 (03) :317-324
[4]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[5]   FRET between cardiac Na+ channel subunits measured with a confocal microscope and a streak camera [J].
Biskup, C ;
Zimmer, T ;
Benndorf, K .
NATURE BIOTECHNOLOGY, 2004, 22 (02) :220-224
[6]  
BORG TK, 1981, FED PROC, V40, P2037
[7]  
BRAND P, 1995, THESIS C BERNARD U L
[8]   Guest editorial: Biological and biologically inspired materials [J].
Bruck, HA .
EXPERIMENTAL MECHANICS, 2002, 42 (04) :359-360
[9]   Imaging transgenic animals [J].
Budinger, TF ;
Benaron, DA ;
Koretsky, AP .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 1999, 1 :611-648
[10]   The expression and role of protein kinase C in neonatal cardiac myocyte attachment, cell volume, and myofibril formation is dependent on the composition of the extracellular matrix [J].
Bullard, TA ;
Borg, TK ;
Price, RL .
MICROSCOPY AND MICROANALYSIS, 2005, 11 (03) :224-234