Closed-loop optimization control on fan speed of air-cooled steam condenser units for energy saving and rapid load regulation

被引:36
|
作者
Yang, Tingting [1 ]
Wang, Wei [1 ]
Zeng, Deliang [1 ]
Liu, Jizhen [1 ]
Cui, Can [1 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-cooled units; Closed-loop control; Fan speed; Condenser pressure; Load change; SOLAR POWER-PLANT; RANKINE-CYCLE ORC; CENTRIFUGAL CHILLERS; HEAT-RECOVERY; PERFORMANCE; DESIGN; WIND;
D O I
10.1016/j.energy.2017.06.142
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to save more energy and quicken the load change speed of air-cooled steam condenser units, the closed-loop optimized control on the fan speed is proposed and its realization is worth making intensive study. In this regard, the study presents the static and dynamic models of air-cooled steam condenser, and the characteristics of turbine power output affected by fan speed. Then, the structure of closed-loop control on fan speed is designed. Furthermore, two optimized methods on condenser pressure based on fan speed control are separately discussed: the optimum condenser pressure is solved by the genetic algorithm to save more energy, and the condenser pressure regulation is combined with traditional boiler-turbine coordinated control to accelerate the load response. Case study in our paper proves that the fan speed optimization can significantly improve the unit load-following capability, and furthermore unit coal consumption has been significantly reduced when the unit operating in a stable load condition. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:394 / 404
页数:11
相关论文
共 3 条
  • [1] Closed-loop Design and Simulation Analysis for Condenser Pressure Control on Direct Air-cooled Units
    Liu, Hui-chao
    Wang, Wei
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, MATERIALS AND ENERGY (5TH ICMEME2016), 2016, 90 : 139 - 142
  • [2] Numerical analysis from the rotational speed regulation within the fan array on the performance of an air-cooled steam condenser
    He, W. F.
    Chen, J. J.
    Han, D.
    Wen, T.
    Luo, L. T.
    Li, R. Y.
    Zhong, W. C.
    APPLIED THERMAL ENGINEERING, 2019, 153 : 352 - 360
  • [3] Analysis of the operation of air-cooled chillers with variable-speed fans for advanced energy-saving-oriented control strategies
    Catrini, Pietro
    La Villetta, M.
    Kumar, Dhirendran Munith
    Morale, Massimo
    Piacentino, Antonio
    APPLIED ENERGY, 2024, 367