Under or overpressure: an audit of endotracheal cuff pressure monitoring at the tertiary care center

被引:1
作者
Viswambharan, Biju [1 ]
Kumari, Manjini Jeyaram [1 ]
Krishnan, Gopala [2 ]
Ramamoorthy, Lakshmi [1 ]
机构
[1] Jawaharlal Inst Postgrad Med Educ & Res, Dept Med Surg Nursing, Coll Nursing, Pondicherry 605006, India
[2] Jawaharlal Inst Postgrad Med Educ & Res, Dept Neurosurg, Pondicherry, India
关键词
airway management; artificial respiration; endotracheal; hospital acquired pneumonia; intubation; mechanical ventilation; ventilator-associated pneumonia; VENTILATOR-ASSOCIATED PNEUMONIA; CRITICALLY-ILL PATIENTS; TUBE CUFF; MICROASPIRATION; PREVALENCE;
D O I
10.4266/acc.2021.00024
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Mechanical ventilation is a lifesaving intervention for critically ill patients but can produce the major complication of ventilator-associated pneumonia (VAP). Inappropriately inflated endotracheal tubes cause potential harm due to high or low pressure; this can be prevented through monitoring protocols. Methods: A cross-sectional study of 348 cuff pressure readings was performed with intubated and mechanically ventilated patients to evaluate the exact proportion of patients in intensive care units (ICUs) where the cuff pressure is optimal and to identify the ICUs where device-based monitoring is available to produce a lower proportion of sub-optimal cuff pressure cases. Every three days, cuff pressure was assessed with a handheld cuff pressure manometer. The corresponding VAP rates of those ICUs were obtained from the hospital infection control department. Results: Cuff pressure of 40.2% was the lower cutoff for the high category, that of optimal was 35.3%, and the highest cutoff of sub-optimal was 24.4%. This study also showed ICUs that had cuff pressure monitoring devices and protocols. Active measurement protocols had a higher proportion of optimal cuff pressure (58.5%) and a lower proportion of sub-optimal and high cuff pressure (19.5% and 22.0%) compared to ICUs with no device-based monitoring protocols. Furthermore, the VAP rate of ICUs exhibited a weak positive correlation with sub-optimal cuff pressure. Conclusions: Device-based cuff pressure monitoring is essential in maintaining adequate cuff pressure but often is inadequate, resulting in high readings. Therefore, this study suggests that device-based cuff pressure monitoring be practiced.
引用
收藏
页码:374 / 379
页数:6
相关论文
共 19 条
[1]  
Akdogan O, 2017, BRAZ J INFECT DIS, V21, P276
[2]   "The multimodal approach for ventilator-associated pneumonia prevention"-requirements for nationwide implementation [J].
Alvarez-Lerma, Francisco ;
Sanchez-Garcia, M. .
ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (21)
[3]   Prevalence and predictors of out-of-range cuff pressure of endotracheal and tracheostomy tubes: a prospective cohort study in mechanically ventilated patients [J].
Alzahrani, Amer R. ;
Al Abbasi, Shatha ;
Abahoussin, Othman Khalid ;
Al Shehri, Tariq Othman ;
Al-Dorzi, Hasan M. ;
Tamim, Hani M. ;
Sadat, Musharaf ;
Arabi, Yaseen M. .
BMC ANESTHESIOLOGY, 2015, 15
[4]  
Fu You, 2014, Zhonghua Wei Zhong Bing Ji Jiu Yi Xue, V26, P870, DOI 10.3760/cma.j.issn.2095-4352.2014.12.005
[5]   Endotracheal Tubes: Old and New [J].
Haas, Carl F. ;
Eakin, Richard M. ;
Konkle, Mark A. ;
Blank, Ross .
RESPIRATORY CARE, 2014, 59 (06) :933-952
[6]   The role of the endotracheal tube cuff in microaspiration [J].
Hamilton, V. Anne ;
Grap, Mary Jo .
HEART & LUNG, 2012, 41 (02) :167-172
[7]   Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials [J].
Huang, Wei Min ;
Huang, Xu An ;
Du, Yan Ping ;
Li, Liu Xia ;
Wu, Fang Fang ;
Hong, Shao Qing ;
Tang, Fang Xuan ;
Ye, Zhang Qiang .
CANADIAN RESPIRATORY JOURNAL, 2019, 2019
[8]   Impact of tapered-cuff tracheal tube on microaspiration of gastric contents in intubated critically ill patients: a multicenter cluster-randomized cross-over controlled trial [J].
Jaillette, Emmanuelle ;
Girault, Christophe ;
Brunin, Guillaume ;
Zerimech, Farid ;
Behal, Helene ;
Chiche, Arnaud ;
Broucqsault-Dedrie, Celine ;
Fayolle, Cyril ;
Minacori, Franck ;
Alves, Isabelle ;
Barrailler, Stephanie ;
Labreuche, Julien ;
Robriquet, Laurent ;
Tamion, Fabienne ;
Delaporte, Emmanuel ;
Thellier, Damien ;
Delcourte, Claire ;
Duhamel, Alain ;
Nseir, Saad .
INTENSIVE CARE MEDICINE, 2017, 43 (11) :1562-1571
[9]   Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study [J].
Jaillette, Emmanuelle ;
Zerimech, Farid ;
De Jonckheere, Julien ;
Makris, Demosthenes ;
Balduyck, Malika ;
Durocher, Alain ;
Duhamel, Alain ;
Nseir, Saad .
BMC ANESTHESIOLOGY, 2013, 13
[10]   Frequent Versus Infrequent Monitoring of Endotracheal Tube Cuff Pressures [J].
Letvin, Adam ;
Kremer, Pamala ;
Silver, Patty C. ;
Samih, Nizama ;
Reed-Watts, Peggy ;
Kollef, Marin H. .
RESPIRATORY CARE, 2018, 63 (05) :495-501