Surgical Punctal Occlusion With a High Heat-Energy Releasing Cautery Device for Severe Dry Eye With Recurrent Punctal Plug Extrusion

被引:26
作者
Ohba, Emii
Dogru, Murat [2 ]
Hosaka, Eri
Yamazaki, Asako
Asaga, Rie [3 ]
Tatematsu, Yukako [4 ]
Ogawa, Yoko [4 ]
Tsubota, Kazuo [4 ]
Goto, Eiki [1 ]
机构
[1] Tsurumi Univ, Dept Ophthalmol, Sch Dent Med, Tsurumi Ku, Yokohama, Kanagawa 2308501, Japan
[2] Keio Univ, Sch Med, Johnson & Johnson Ocular Surface Visual Opt Dept, Tokyo, Japan
[3] Ichikawa Gen Hosp, Tokyo Dent Coll, Dept Ophthalmol, Ichikawa, Japan
[4] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
关键词
FUNCTIONAL VISUAL-ACUITY; EFFICACY; CRITERIA; SYSTEM; LASER; SICCA;
D O I
10.1016/j.ajo.2010.08.045
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion. DESIGN: Prospective, interventional case series. METHODS: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined. RESULTS: Three months after surgical cauterization, symptom score decreased from 3.9 +/- 0.23 to 0.56 +/- 0.84 (P < .0001). Logarithm of the minimal angle of resolution hest-corrected visual acuity improved from 0.11 +/- 0.30 to 0.013 +/- 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%). CONCLUSIONS: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity. (Am J Ophthalmol 2011;151:483-487. 2011 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:483 / 487
页数:5
相关论文
共 30 条
[1]  
[Anonymous], 1997, OPHTHALMOLOGY, V104, P1521
[2]  
BAN Y, JPN J OPHTH IN PRESS
[3]  
BENSON DR, 1992, OPHTHALMOLOGY, V99, P618
[4]   Diagnostic usefulness and cutoff value of Schirmer's I test in the Japanese diagnostic criteria of dry eye [J].
Danjo, Y .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1997, 235 (12) :761-766
[5]   Clinical characteristics of conjunctivochalasis with or without aqueous tear deficiency [J].
Di Pascuale, MA ;
Espana, EM ;
Kawakita, T ;
Tseng, SCG .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (03) :388-392
[6]  
DOHLMAN CH, 1978, OPHTHALMOLOGY, V85, P1277
[7]   Ocular surface changes in keratoconjunctivitis sicca with silicone punctum plug occlusion [J].
Dursun, D ;
Ertan, A ;
Bilezikçi, B ;
Akova, YA ;
Pelit, A .
CURRENT EYE RESEARCH, 2003, 26 (05) :263-269
[8]   SJOGRENS-SYNDROME - PROPOSED CRITERIA FOR CLASSIFICATION [J].
FOX, RI ;
ROBINSON, CA ;
CURD, JG ;
KOZIN, F ;
HOWELL, FV .
ARTHRITIS AND RHEUMATISM, 1986, 29 (05) :577-585
[9]   Kinetic analysis of tear interference images in aqueous tear deficiency dry eye before and after punctal occlusion [J].
Goto, E ;
Tseng, SCG .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (05) :1897-1905
[10]   Improved functional visual acuity after punctal occlusion in dry eye patients [J].
Goto, E ;
Yagi, Y ;
Kaido, M ;
Matsumoto, Y ;
Konomi, K ;
Tsubota, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (05) :704-705