Assessment of ventilation and indoor air pollutants in nursery and elementary schools in France

被引:102
作者
Canha, N. [1 ,2 ]
Mandin, C. [2 ]
Ramalho, O. [2 ]
Wyart, G. [2 ]
Riberon, J. [2 ]
Dassonville, C. [2 ]
Hanninen, O. [3 ]
Almeida, S. M. [1 ]
Derbez, M. [2 ]
机构
[1] Univ Lisbon, Ctr Ciencias & Tecnol Nucl, Inst Super Tecn, Bobadela LRS, P-1699 Lisbon, Portugal
[2] Univ Paris Est, CSTB, OQAI French Indoor Air Qual Observ, 84 Ave Jean Jaures, F-77447 Champs Sur Marne 2, Marne La Vallee, France
[3] Natl Inst Hlth & Welf THL, Kuopio, Finland
关键词
Air stuffiness index; CO2; Volatile organic compounds; Aldehydes; Particulate matter; PARTICULATE MATTER; THERMAL CONDITIONS; FRENCH SCHOOLS; TRACE-ELEMENTS; QUALITY; OUTDOOR; CLASSROOMS; RATES; PM2.5; EXPOSURE;
D O I
10.1111/ina.12222
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this study was to characterize the relationship between Indoor Air Quality ( IAQ) and ventilation in French classrooms. Various parameters were measured over one school week, including volatile organic compounds, aldehydes, particulate matter ( PM2.5 mass concentration and number concentration), carbon dioxide ( CO2), air temperature, and relative humidity in 51 classrooms at 17 schools. The ventilation was characterized by several indicators, such as the air exchange rate, ventilation rate ( VR), and air stuffiness index ( ICONE), that are linked to indoor CO2 concentration. The influences of the season ( heating or non-heating), type of school ( nursery or elementary), and ventilation on the IAQ were studied. Based on the minimum value of 4.2 l/s per person required by the French legislation for mechanically ventilated classrooms, 91% of the classrooms had insufficient ventilation. The VR was significantly higher in mechanically ventilated classrooms compared with naturally ventilated rooms. The correlations between IAQ and ventilation vary according to the location of the primary source of each pollutant ( outdoor vs. indoor), and for an indoor source, whether it is associated with occupant activity or continuous emission.
引用
收藏
页码:350 / 365
页数:16
相关论文
共 60 条
  • [1] Children exposure to atmospheric particles in indoor of Lisbon primary schools
    Almeida, Susana Marta
    Canha, Nuno
    Silva, Ana
    Freitas, Maria do Carmo
    Pegas, Priscilla
    Alves, Celia
    Evtyugina, Margarita
    Pio, Casimiro Adriao
    [J]. ATMOSPHERIC ENVIRONMENT, 2011, 45 (40) : 7594 - 7599
  • [2] INDOOR AIR QUALITY AND SOURCES IN SCHOOLS AND RELATED HEALTH EFFECTS
    Annesi-Maesano, Isabella
    Baiz, Nour
    Banerjee, Soutrik
    Rudnai, Peter
    Rive, Solenne
    [J]. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2013, 16 (08): : 491 - 550
  • [3] Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study
    Annesi-Maesano, Isabella
    Hulin, Marion
    Lavaud, Francois
    Raherison, Chantal
    Kopferschmitt, Christine
    de Blay, Frederic
    Charpin, Denis Andre
    Denis, Caillaud
    [J]. THORAX, 2012, 67 (08) : 682 - 688
  • [4] [Anonymous], 2005, WHO REGIONAL OFFICE
  • [5] [Anonymous], 2007, 152512007 EN
  • [6] ASHRAE, 2013, ASHRAE Standard 62.1-2013
  • [7] Ventilation rates in schools and pupils' performance
    Bako-Biro, Zs.
    Clements-Croome, D. J.
    Kochhar, N.
    Awbi, H. B.
    Williams, M. J.
    [J]. BUILDING AND ENVIRONMENT, 2012, 48 : 215 - 223
  • [8] Relationship between outdoor and indoor air quality in eight French schools
    Blondeau, P
    Iordache, V
    Poupard, O
    Genin, D
    Allard, F
    [J]. INDOOR AIR, 2005, 15 (01) : 2 - 12
  • [9] The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom
    Branis, M
    Rezácová, P
    Domasová, M
    [J]. ENVIRONMENTAL RESEARCH, 2005, 99 (02) : 143 - 149
  • [10] Brelih N., 2011, P 32 AIVC C 1 TIGHTV