Final report: key comparison EURAMET.AUV.A-K5

被引:0
|
作者
Avison, Janine [1 ]
Harris, Peter [1 ]
Robinson, Stephen [1 ]
Rodrigues, Dominique [2 ]
Guglielmone, Claudio [3 ]
Hof, Christian [4 ]
Sadikoglu, Enver [5 ]
Chushkov, Marin [6 ]
Zelenika, Slobodan [7 ]
Rosenkrantz, Peter [8 ]
Andersson, Hakan
Fedtke, Thomas
Koch, Christian
Martin, Nieves Medina
Ruiz, Salustiano
Shawky, Hany
机构
[1] NPL, Hampton Rd, Teddington TW11 0LW, Middx, England
[2] LNE, Rue Gaston Boissier 1, F-75724 Paris 15, France
[3] INRIM, Str Cacce 91, I-10135 Turin, Italy
[4] METAS, Lindenweg 50, CH-3003 Bern, Switzerland
[5] UME, POB 54,Baris Mah Dr Zeki Acar Cad 1, TR-41470 Kocaeli, Turkey
[6] BIM, 52B,GM Dimitrov Blvd, Sofia 1040, Bulgaria
[7] DMDM, Mike Alasa 14, Beograd 11000, Serbia
[8] BEV, Arltgasse 35, A-1160 Vienna, Austria
关键词
acoustics; microphones; metrology; key comparison; pressure calibration;
D O I
10.1088/0026-1394/56/1A/09001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This is the final (Draft B) report for key comparison EURAMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national metrology institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two travelling standard microphones were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. The analysis used the results for one of the microphones only and values for both sensitivity level and sensitivity phase and have been linked to the CCAUV.A K5 key comparison reference value (KCRV) via two linking laboratories (NPL and INRIM).
引用
收藏
页码:1 / 43
页数:3
相关论文
共 50 条
  • [1] Final report on key comparison EURAMET.AUV.V-K2
    Kolasa, Joanna
    Virovska, Daniela
    METROLOGIA, 2020, 57 (1A)
  • [2] Report on the EURAMET key comparison EURAMET.AUV.V-K3
    Bartoli, C.
    Prasil, M.
    Andersson, H.
    Hof, C.
    Schiavi, A.
    Kolasa, J.
    Medina, N.
    Bruns, T.
    Gazioch, S.
    Licht, T. R.
    Hamalainen, J.
    METROLOGIA, 2015, 52
  • [3] Final report on key comparison APMP.AUV.A-K1
    Horiuchi, Ryuzo
    Takahashi, Hironobu
    Fujimori, Takeshi
    Sato, Sojun
    METROLOGIA, 2007, 44
  • [4] FINAL REPORT ON KEY COMPARISON APMP.AUV.A-K3
    Kwon, Hyu-Sang
    Suh, Sang-Joon
    Suh, Jae-Gap
    METROLOGIA, 2012, 49
  • [5] Final report on the supplementary comparison EURAMET.AUV.V-S1
    Rosenkranz P.
    Virovska D.
    Prasil M.
    Ribeiro L.F.
    Maina A.K.
    Hof C.
    Hämäläinen J.
    Bruns T.
    Sadikoglu E.
    Metrologia, 2022, 59 (1 A)
  • [6] Final report on the supplementary comparison EURAMET.AUV.V-S2
    Rosenkranz P.
    Hof C.
    Metrologia, 2022, 59 (1 A)
  • [7] Final Report EURAMET.AUV.A-S1
    Barrera-Figueroa, Salvador
    Nielsen, Lars
    METROLOGIA, 2013, 50
  • [8] EURAMET Key-Comparison Luminous Intensity EURAMET.PR-K3.a Final Report, May 2014
    Sperling, A.
    Sauter, G.
    Lindner, D.
    Eltmann, M.
    METROLOGIA, 2014, 51
  • [9] Final report of the key comparison of APMP.AUV.V-K2
    Usuda, Takashi
    Ota, Akihiro
    Nozato, Hideaki
    Ishigami, Tamio
    Kokuyama, Wataru
    Plangsangmas, Virat
    Rattanangkul, Pairoj
    Tsuei, Kuang Yih
    Huang, Yu-Chung
    Keong, Chan Chee
    METROLOGIA, 2017, 54
  • [10] Final Report on the Key Comparison EUROMET-AUV.V-K1.1
    Bruns, Th.
    METROLOGIA, 2010, 47