A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging

被引:17
|
作者
Park, Jinil [1 ,2 ]
Shin, Taehoon [3 ]
Yoon, Soon Ho [4 ,5 ]
Goo, Jin Mo [4 ,5 ,6 ]
Park, Jang-Yeon [1 ,2 ]
机构
[1] Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] Univ Maryland, Dept Diagnost Radiol & Nucl Med, Baltimore, MD 21201 USA
[4] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[5] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[6] Seoul Natl Univ, Canc Res Inst, Seoul, South Korea
关键词
3D radial UTE imaging; lung MRI; retrospective respiratory gating; k-space sample uniformity; NUCLEAR-MAGNETIC-RESONANCE; MRI; RECONSTRUCTION; DESIGN; MOTION; TRAJECTORIES; ANGIOGRAPHY; ACQUISITION; SPIRALS;
D O I
10.1002/nbm.3494
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this work was to develop a 3D radial-sampling strategy which maintains uniform k-space sample density after retrospective respiratory gating, and demonstrate its feasibility in free-breathing ultrashort-echo-time lung MRI. A multi-shot, interleaved 3D radial sampling function was designed by segmenting a single-shot trajectory of projection views such that each interleaf samples k-space in an incoherent fashion. An optimal segmentation factor for the interleaved acquisition was derived based on an approximate model of respiratory patterns such that radial interleaves are evenly accepted during the retrospective gating. The optimality of the proposed sampling scheme was tested by numerical simulations and phantom experiments using human respiratory waveforms. Retrospectively, respiratory-gated, free-breathing lung MRI with the proposed sampling strategy was performed in healthy subjects. The simulation yielded the most uniform k-space sample density with the optimal segmentation factor, as evidenced by the smallest standard deviation of the number of neighboring samples as well as minimal side-lobe energy in the point spread function. The optimality of the proposed scheme was also confirmed by minimal image artifacts in phantom images. Human lung images showed that the proposed sampling scheme significantly reduced streak and ring artifacts compared with the conventional retrospective respiratory gating while suppressing motion-related blurring compared with full sampling without respiratory gating. In conclusion, the proposed 3D radial-sampling scheme can effectively suppress the image artifacts due to non-uniform k-space sample density in retrospectively respiratory-gated lung MRI by uniformly distributing gated radial views across the k-space. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:576 / 587
页数:12
相关论文
共 16 条
  • [1] Comparison of diagnostic quality of 3D ultrashort-echo-time techniques for pulmonary magnetic resonance imaging in free-breathing
    Metz, Corona
    Weng, Andreas Max
    Boeckle, David
    Heidenreich, Julius Frederik
    Slawig, Anne
    Benkert, Thomas
    Kraus, Sabrina
    Koestler, Herbert
    Veldhoen, Simon
    ACTA RADIOLOGICA, 2023, 64 (05) : 1851 - 1858
  • [2] A Robust Self-navigation for Respiratory Gating in 3D Radial Ultrashort Echo-time Lung MRI using Concurrent Dephasing and Excitation
    Park, Jinil
    Lee, Seokwon
    Shin, Taehoon
    Oh, Se-Hong
    Park, Jang-Yeon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (01) : 138 - 144
  • [3] A Robust Self-navigation for Respiratory Gating in 3D Radial Ultrashort Echo-time Lung MRI using Concurrent Dephasing and Excitation
    Jinil Park
    Seokwon Lee
    Taehoon Shin
    Se-Hong Oh
    Jang-Yeon Park
    Journal of the Korean Physical Society, 2018, 73 : 138 - 144
  • [4] Oxygen-enhanced 3D radial ultrashort echo time magnetic resonance imaging in the healthy human lung
    Kruger, Stanley J.
    Fain, Sean B.
    Johnson, Kevin M.
    Cadman, Robert V.
    Nagle, Scott K.
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1535 - 1541
  • [5] 3D sampling of K-Space with Non-Cartesian Trajectories in MR Imaging
    Dundar, Mehmet Sait
    Gumus, Kazim Z.
    Yilmaz, Bulent
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2025, 40 (02): : 1039 - 1048
  • [6] 3D ultrashort echo time MRI of the lung using stack-of-spirals and spherical k-Space coverages: Evaluation in healthy volunteers and parenchymal diseases
    Dournes, Gael
    Yazbek, Joseph
    Benhassen, Wadie
    Benlala, Ilyes
    Blanchard, Elodie
    Truchetet, Marie-Elise
    Macey, Julie
    Berger, Patrick
    Laurent, Francois
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (06) : 1489 - 1497
  • [7] Cardiac-induced physiological noise in 3D gradient echo brain imaging: Effect of k-space sampling scheme
    Kristoffersen, Anders
    Goa, Pal Erik
    JOURNAL OF MAGNETIC RESONANCE, 2011, 212 (01) : 74 - 85
  • [8] Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI
    Gai, Neville D.
    Malayeri, Ashkan A.
    Bluemke, David A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (04) : 387 - 395
  • [9] Sodium magnetic resonance imaging using ultra-short echo time sequences with anisotropic resolution and uniform k-space sampling
    Konstandin, Simon
    Kraemer, Philipp
    Guenther, Matthias
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2015, 33 (03) : 319 - 327
  • [10] Four-Dimensional Magnetic Resonance Imaging With 3-Dimensional Radial Sampling and Self-Gating-Based K-Space Sorting: Early Clinical Experience on Pancreatic Cancer Patients
    Yang, Wensha
    Fan, Zhaoyang
    Tuli, Richard
    Deng, Zixin
    Pang, Jianing
    Wachsman, Ashley
    Reznik, Robert
    Sandler, Howard
    Li, Debiao
    Fraass, Benedick A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (05): : 1136 - 1143