Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

被引:18
作者
Olivieri, Laura [1 ,2 ]
Cross, Russell [1 ]
O'Brien, Kendall J. [1 ,2 ]
Xue, Hui [2 ]
Kellman, Peter [2 ]
Hansen, Michael S. [2 ]
机构
[1] Childrens Natl Hlth Syst, Div Cardiol, W3-200,111 Michigan Ave NW, Washington, DC 20010 USA
[2] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Children; Free breathing; Heart; Late gadolinium enhancement; Magnetic resonance imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; POPULATION; TRUEFISP; RISK;
D O I
10.1007/s00247-016-3553-7
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late-enhancement imaging with motion-corrected averaging is feasible in children, robust at high heart rates and with variable R-R intervals, and can be performed without breath-holding with higher image quality ratings than standard breath-held techniques. Use of free-breathing single-shot motion-corrected technique does not compromise LGE image quality in children who can hold their breath, and it can significantly improve image quality in children who cannot hold their breath or who have significant arrhythmia.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 50 条
  • [41] Improved free-breathing liver fat and iron quantification using a 2D chemical shift-encoded MRI with flip angle modulation and motion-corrected averaging
    Starekova, Jitka
    Zhao, Ruiyang
    Colgan, Timothy J.
    Johnson, Kevin M.
    Rehm, Jennifer L.
    Wells, Shane A.
    Reeder, Scott B.
    Hernando, Diego
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5458 - 5467
  • [42] Free-Breathing Combined Three-Dimensional Phase Sensitive Late Gadolinium Enhancement and T1 Mapping for Myocardial Tissue Characterization
    Weingaertner, Sebastian
    Akcakaya, Mehmet
    Roujol, Sebastien
    Basha, Tamer
    Tschabrunn, Cory
    Berg, Sophie
    Anter, Elad
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1032 - 1041
  • [43] Image Evaluation of Free-breathing Navigator Echo and Triggered Cardiac-gated Delayed Myocardial Enhancement Magnetic Resonance Imaging in Sedated Infants
    Matsuura, Ryutaro
    Goto, Sachiko
    Sato, Shuhei
    Akagi, Noriaki
    Tahara, Seiji
    ACTA MEDICA OKAYAMA, 2018, 72 (03) : 267 - 273
  • [44] Effect of contrast dosage on image quality of MR angiography and Late Gadolinium enhancement imaging of the left atrium
    Sathya Vijayakumar
    Eugene G Kholmovski
    Chris J McGann
    Daniel Sommers
    Edward VR DiBella
    Nassir F Marrouche
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [45] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Lenhard Pennig
    Simon Lennartz
    Anton Wagner
    Marcel Sokolowski
    Matej Gajzler
    Svenja Ney
    Kai Roman Laukamp
    Thorsten Persigehl
    Alexander Christian Bunck
    David Maintz
    Kilian Weiss
    Claas Philip Naehle
    Jonas Doerner
    Journal of Cardiovascular Magnetic Resonance, 22
  • [46] High-resolution Free-breathing late gadolinium enhancement Cardiovascular magnetic resonance to diagnose myocardial injuries following COVID-19 infection
    Bustin, Aurelien
    Sridi, Soumaya
    Gravinay, Pierre
    Legghe, Benoit
    Gosse, Philippe
    Ouattara, Alexandre
    Roze, Hadrien
    Coste, Pierre
    Gerbaud, Edouard
    Desclaux, Arnaud
    Boyer, Alexandre
    Prevel, Renaud
    Gruson, Didier
    Bonnet, Fabrice
    Issa, Nahema
    Montaudon, Michel
    Laurent, Francois
    Stuber, Matthias
    Camou, Fabrice
    Cochet, Hubert
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 144
  • [47] The image quality and diagnostic accuracy of T1-mapping-based synthetic late gadolinium enhancement imaging: comparison with conventional late gadolinium enhancement imaging in real-life clinical situation
    Suji Lee
    Panki Kim
    Dong Jin Im
    Young Joo Suh
    Yoo Jin Hong
    Byoung Wook Choi
    Young Jin Kim
    Journal of Cardiovascular Magnetic Resonance, 24
  • [48] Comparison of Free-Breathing With Navigator-Triggered Technique in Diffusion Weighted Imaging for Evaluation of Small Hepatocellular Carcinoma: Effect on Image Quality and Intravoxel Incoherent Motion Parameters
    Shan, Yan
    Zeng, Meng-su
    Liu, Kai
    Miao, Xi-yin
    Lin, Jiang
    Fu, Cai Xia
    Xu, Peng-ju
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 709 - 715
  • [49] Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose
    Bodelle, Boris
    Fischbach, Constanze
    Booz, Christian
    Yel, Ibrahim
    Frellesen, Claudia
    Beeres, Martin
    Vogl, Thomas J.
    Scholtz, Jan-Erik
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 89 : 208 - 214
  • [50] Late gadolinium enhancement magnetic resonance imaging for the assessment of myocardial infarction: comparison of image quality between single and double doses of contrast agents
    Yeo Koon Kim
    Eun-Ah Park
    Whal Lee
    Sang Yoon Kim
    Jin Wook Chung
    The International Journal of Cardiovascular Imaging, 2014, 30 : 129 - 135