Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children

被引:18
作者
Olivieri, Laura [1 ,2 ]
Cross, Russell [1 ]
O'Brien, Kendall J. [1 ,2 ]
Xue, Hui [2 ]
Kellman, Peter [2 ]
Hansen, Michael S. [2 ]
机构
[1] Childrens Natl Hlth Syst, Div Cardiol, W3-200,111 Michigan Ave NW, Washington, DC 20010 USA
[2] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Children; Free breathing; Heart; Late gadolinium enhancement; Magnetic resonance imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; MYOCARDIAL-INFARCTION; POPULATION; TRUEFISP; RISK;
D O I
10.1007/s00247-016-3553-7
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The value of late-gadolinium-enhancement (LGE) imaging in the diagnosis and management of pediatric and congenital heart disease is clear; however current acquisition techniques are susceptible to error and artifacts when performed in children because of children's higher heart rates, higher prevalence of sinus arrhythmia, and inability to breath-hold. Commonly used techniques in pediatric LGE imaging include breath-held segmented FLASH (segFLASH) and steady-state free precession-based (segSSFP) imaging. More recently, single-shot SSFP techniques with respiratory motion-corrected averaging have emerged. This study tested and compared single-shot free-breathing LGE techniques with standard segmented breath-held techniques in children undergoing LGE imaging. Thirty-two consecutive children underwent clinically indicated late-enhancement imaging using intravenous gadobutrol 0.15 mmol/kg. Breath-held segSSFP, breath-held segFLASH, and free-breathing single-shot SSFP LGE sequences were performed in consecutive series in each child. Two blinded reviewers evaluated the quality of the images and rated them on a scale of 1-5 (1 = poor, 5 = superior) based on blood pool-myocardial definition, presence of cardiac motion, presence of respiratory motion artifacts, and image acquisition artifact. We used analysis of variance (ANOVA) to compare groups. Patients ranged in age from 9 months to 18 years, with a mean +/- standard deviation (SD) of 13.3 +/- 4.8 years. R-R interval at the time of acquisition ranged 366-1,265 milliseconds (ms) (47-164 beats per minute [bpm]), mean +/- SD of 843+/-231 ms (72+/-21 bpm). Mean +/- SD quality ratings for long-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.1+/-0.9, 3.4+/-0.9 and 4.0+/-0.9, respectively (P < 0.01 by ANOVA). Mean +/- SD quality ratings for short-axis imaging for segFLASH, segSSFP and single-shot SSFP were 3.4+/-1, 3.8+/-0.9 and 4.3+/-0.7, respectively (P < 0.01 by ANOVA). Single-shot late-enhancement imaging with motion-corrected averaging is feasible in children, robust at high heart rates and with variable R-R intervals, and can be performed without breath-holding with higher image quality ratings than standard breath-held techniques. Use of free-breathing single-shot motion-corrected technique does not compromise LGE image quality in children who can hold their breath, and it can significantly improve image quality in children who cannot hold their breath or who have significant arrhythmia.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 50 条
  • [21] Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging
    Merlocco, Anthony
    Olivieri, Laura
    Kellman, Peter
    Xue, Hui
    Cross, Russell
    PEDIATRIC CARDIOLOGY, 2019, 40 (01) : 79 - 88
  • [22] Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast
    Holtackers, Robert J.
    Gommers, Suzanne
    Van De Heyning, Caroline M.
    Mihl, Casper
    Smink, Jouke
    Higgins, David M.
    Wildberger, Joachim E.
    ter Bekke, Rachel M. A.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (05) : 335 - 340
  • [23] Free-breathing late gadolinium enhancement CMR with a fixed short scan time using CosMo
    Mehdi H Moghari
    Hussein Rayatzadeh
    Susie Hong
    Raymond H Chan
    Mehmet Akcakaya
    Beth Goddu
    Lois A Goepfert
    Kraig V Kissinger
    Warren J Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [24] 3D free-breathing late gadolinium enhancement 3T MRI: comparison with standard 2D Imaging
    Maurice Bizino
    Qian Tao
    Jacob Amersfoort
    Rob J van der Geest
    Hildo J Lamb
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [25] Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging
    Cross, Russell
    Olivieri, Laura
    O'Brien, Kendall
    Kellman, Peter
    Xue, Hui
    Hansen, Michael
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [26] High spatial resolution free-breathing 3D late gadolinium enhancement cardiac magnetic resonance imaging in ischaemic and non-ischaemic cardiomyopathy: quantitative assessment of scar mass and image quality
    Maurice B. Bizino
    Qian Tao
    Jacob Amersfoort
    Hans-Marc J. Siebelink
    Pieter J. van den Bogaard
    Rob J. van der Geest
    Hildo J. Lamb
    European Radiology, 2018, 28 : 4027 - 4035
  • [27] Improved myocardial scar visualization with fast free-breathing motion- compensated black-blood T1-rho-prepared late gadolinium enhancement MRI
    Sridi, Soumaya
    Nunez-Garcia, Marta
    Sermesant, Maxime
    Maillot, Aurelien
    El Hamrani, Dounia
    Magat, Julie
    Naulin, Jerome
    Laurent, Francois
    Montaudon, Michel
    Jais, Pierre
    Stuber, Matthias
    Cochet, Hubert
    Bustin, Aurelien
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (12) : 607 - 617
  • [28] Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging
    Munoz, Camila
    Bustin, Aurelien
    Neji, Radhouene
    Kunze, Karl P.
    Forman, Christoph
    Schmidt, Michaela
    Hajhosseiny, Reza
    Masci, Pier-Giorgio
    Zeilinger, Martin
    Wuest, Wolfgang
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [29] Free-Breathing, Motion-Corrected, Highly Efficient Whole Heart T2 Mapping at 3T with Hybrid Radial-Cartesian Trajectory
    Yang, Hsin-Jung
    Sharif, Behzad
    Pang, Jianing
    Kali, Avinash
    Bi, Xiaoming
    Cokic, Ivan
    Li, Debiao
    Dharmakumar, Rohan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 126 - 136
  • [30] Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging
    Anthony Merlocco
    Laura Olivieri
    Peter Kellman
    Hui Xue
    Russell Cross
    Pediatric Cardiology, 2019, 40 : 79 - 88