Rapid and sensitive high-performance liquid chromatographic method for simultaneous determination of retinol, α-tocopherol, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human plasma with photodiode-array ultraviolet detection

被引:47
作者
Alvarez, JC [1 ]
De Mazancourt, P [1 ]
机构
[1] Ctr Hosp Univ Raymond Poincare, AP HP, Biochim Lab, F-92380 Garches, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 755卷 / 1-2期
关键词
vitamins; retinol; alpha-tocopherol; 25-hydroxyvitamin D;
D O I
10.1016/S0378-4347(01)00047-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new rapid and sensitive high-performance liquid chromatographic method using 0.5 mi of plasma has been developed for the simultaneous determination of retinol (vitamin A), ol-tocopherol (vitamin E), 25-hydroxyvitamin D-2 and 25-hydroxyvitamin D-3. The eluate was monitored with a photodiode-array detector with two fixed wavelengths (267 nm for vitamin D, 292 nm for alpha -tocopherol acid retinol). For all compounds, including internal standards, the method provides extraction recoveries greater than 81%. Detection limits were equal to or lower than 1.5 mug/l for the 4 vitamins. Linearity of standards was excellent (r>0.999 in all cases). Intra-day and inter-day precision were generally acceptable; the intra-day-assay C.V, was 3/4 7.7 for all compounds and the inter-day-assay CV was <9.2% except for the lower concentrations of 25-hydroxyvitamin D-3, 25-hydroxyvitamin D-2 and <alpha>-tocopherol (10.8, 11.8 and 11.9, respectively). The important properties of the present method are its ease of use, its rapidity, since sample preparation was achieved in 15 min and all the compounds were eluted in less than 15 min, and its small sample volume required (=0.5 mi), which enables it to be used in pediatric practice. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 27 条
[1]  
Abahusain MA, 1998, BIOMED CHROMATOGR, V12, P89, DOI 10.1002/(SICI)1099-0801(199803/04)12:2<89::AID-BMC732>3.0.CO
[2]  
2-0
[4]   A SIMPLIFIED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF VITAMIN-D3, 25-HYDROXYVITAMIN-D2 AND 25-HYDROXYVITAMIN-D3 IN HUMAN SERUM [J].
AKSNES, L .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1992, 52 (03) :177-182
[5]   SIMULTANEOUS DETERMINATION OF RETINOL, ALPHA-TOCOPHEROL, AND 25-HYDROXYVITAMIN-D IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
AKSNES, L .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1994, 18 (03) :339-343
[6]   SIMULTANEOUS DETERMINATION OF VITAMIN-A ACETATE, VITAMIN-D2, AND VITAMIN-E ACETATE IN MULTIVITAMIN MINERAL TABLETS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COUPLED COLUMNS [J].
BARNETT, SA ;
FRICK, LW .
ANALYTICAL CHEMISTRY, 1979, 51 (06) :641-645
[7]   SIMULTANEOUS DETERMINATION OF VITAMIN-A, VITAMIN-D2 OR VITAMIN-D3, VITAMIN-E AND VITAMIN-K1 IN INFANT FORMULAS AND DAIRY-PRODUCTS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
BARNETT, SA ;
FRICK, LW ;
BAINE, HM .
ANALYTICAL CHEMISTRY, 1980, 52 (04) :610-614
[8]  
BOSTICK RM, 1993, CANCER RES, V53, P4230
[9]   Determination of vitamins D2, D3, K1 and K3 and some hydroxy metabolites of vitamin D3 in plasma using a continuous clean-up-preconcentration procedure coupled on-line with liquid chromatography UV detection [J].
Boyer, FO ;
Romero, JMF ;
de Castro, MDL ;
Quesada, JM .
ANALYST, 1999, 124 (03) :401-406
[10]   COMPARISON OF REVERSED-PHASE AND ADSORPTION MODES OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE ASSAY OF FAT SOLUBLE VITAMINS IN MULTIVITAMIN TABLETS [J].
BURNS, DT ;
MACKAY, C .