Rapid and sensitive high-performance liquid chromatographic method for simultaneous determination of retinol, α-tocopherol, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human plasma with photodiode-array ultraviolet detection

被引:47
|
作者
Alvarez, JC [1 ]
De Mazancourt, P [1 ]
机构
[1] Ctr Hosp Univ Raymond Poincare, AP HP, Biochim Lab, F-92380 Garches, France
关键词
vitamins; retinol; alpha-tocopherol; 25-hydroxyvitamin D;
D O I
10.1016/S0378-4347(01)00047-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new rapid and sensitive high-performance liquid chromatographic method using 0.5 mi of plasma has been developed for the simultaneous determination of retinol (vitamin A), ol-tocopherol (vitamin E), 25-hydroxyvitamin D-2 and 25-hydroxyvitamin D-3. The eluate was monitored with a photodiode-array detector with two fixed wavelengths (267 nm for vitamin D, 292 nm for alpha -tocopherol acid retinol). For all compounds, including internal standards, the method provides extraction recoveries greater than 81%. Detection limits were equal to or lower than 1.5 mug/l for the 4 vitamins. Linearity of standards was excellent (r>0.999 in all cases). Intra-day and inter-day precision were generally acceptable; the intra-day-assay C.V, was 3/4 7.7 for all compounds and the inter-day-assay CV was <9.2% except for the lower concentrations of 25-hydroxyvitamin D-3, 25-hydroxyvitamin D-2 and <alpha>-tocopherol (10.8, 11.8 and 11.9, respectively). The important properties of the present method are its ease of use, its rapidity, since sample preparation was achieved in 15 min and all the compounds were eluted in less than 15 min, and its small sample volume required (=0.5 mi), which enables it to be used in pediatric practice. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [1] Ultra-Performance Liquid Chromatographic (UPLC) Method with Photodiode Array (PDA) Ultraviolet Detection for Simultaneous Determination of 25-Hydroxyvitamin D3 and D2, Retinol, and Tocopherols in Human Plasma
    Cui, Hongjie
    Schulze, Kerry J.
    Charurat, Manhattan
    Christian, Parul
    FASEB JOURNAL, 2012, 26
  • [2] High-performance liquid chromatography and coulometric electrode array detector in serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 analyses
    Nurmi, Tarja
    Tuomainen, Tomi-Pekka
    Virtanen, Jyrki
    Mursu, Jaakko
    Voutilainen, Sari
    ANALYTICAL BIOCHEMISTRY, 2013, 435 (01) : 1 - 9
  • [3] Analysis of retinol, -tocopherol, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in plasma of patients with cardiovascular disease by HPLC-MS/MS method
    Karazniewicz-Lada, Marta
    Glowka, Anna
    Komosa, Anna
    Kruszyna, Lukasz
    Graczyk-Szuster, Agnieszka
    Lesiak, Maciej
    Sowinska, Dagmara
    Przyslawski, Juliusz
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (09)
  • [4] DETERMINATION OF 25-HYDROXYVITAMIN D2 AND 25-HYDROXYVITAMIN D3 IN HUMAN-PLASMA USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    EISMAN, JA
    SHEPARD, RM
    DELUCA, HF
    ANALYTICAL BIOCHEMISTRY, 1977, 80 (01) : 298 - 305
  • [5] Simultaneous determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human serum by ultra performance liquid chromatography: An economical and validated method with bovine serum albumin
    Chin, Siok-Fong
    Osman, Junaida
    Jamal, Rahman
    CLINICA CHIMICA ACTA, 2018, 485 : 60 - 66
  • [6] Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum
    Schleicher, Rosemary L.
    Encisco, Sara E.
    Chaudhary-Webb, Madhulika
    Paliakov, Ekaterina
    McCoy, Leslie F.
    Pfeiffer, Christine M.
    CLINICA CHIMICA ACTA, 2011, 412 (17-18) : 1594 - 1599
  • [7] The effects of calibration matrix on the reported levels of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human serum
    Yates, A. M.
    Owen, L. J.
    Calton, L. J.
    Gillingwater, S. D.
    Keevil, B. G.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A141 - A141
  • [8] The recognition of 25-hydroxyvitamin D2 and D3 by a new binding protein based 25-hydroxyvitamin D assay
    Su, Zengliu
    Slay, Brian R.
    Carr, Randall
    Zhu, Yusheng
    CLINICA CHIMICA ACTA, 2013, 417 : 62 - 66
  • [9] Simultaneous determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human plasma by liquid chromatography-tandem mass spectrometry employing derivatization with a Cookson-type reagent
    Higashi, T
    Awada, D
    Shimada, K
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2001, 24 (07) : 738 - 743
  • [10] Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method
    Abouzid, Mohamed
    Karazniewicz-Lada, Marta
    Pawlak, Kornel
    Burchardt, Pawel
    Kruszyna, Lukasz
    Glowka, Franciszek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159