Use of optically stimulated luminescence dosimeter and radiophotoliminescent glass dosimeter for dose measurement in dual-source dual-energy computed tomography

被引:2
作者
Hirosawa, Ayaka [1 ,2 ]
Matsubara, Kosuke [3 ]
Morioka, Yusuke [1 ,2 ]
Kitagawa, Masayasu [1 ,2 ]
Chusin, Thunyarat [2 ,4 ]
Takemura, Akihiro [3 ]
机构
[1] Toyama Prefectural Cent Hosp, Dept Med Technol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Quantum Med Technol, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok 65000, Thailand
关键词
Dual-source dual-energy computed tomography (Dual-source DECT); Optically stimulated luminescence dosimeter (OSLD); Radiophotoluminescent glass dosimeter (RPLD); Dosimetry; EXPOSURE; NANODOT; OSLDS;
D O I
10.1007/s13246-021-01063-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to evaluate properties of optically stimulated luminescence dosimeters (OSLDs) and radiophotoluminescent glass dosimeters (RPLDs) used in dual-source dual-energy (DE) computed tomography (DECT) dosimetry. Energy dependence was evaluated in single-energy (SE) and DE modes, and their relative dose responses differed by 3.8% and 6.6% under equivalent effective energy with OSLD and RPLD, respectively. Dose variation was evaluated using coefficients of variation of dose values from 10 dosimeters, and dose variation of OSLD and RPLD in SE mode ranged from 2.1 to 3.0% and from 2.1 to 2.8%, and those in the DE mode were 1.8 and 2.6%, respectively. Dose linearity was evaluated from 1 to 150 mGy, and linear relationships of dose response were observed between the dosimeters and the ionization chamber (correlation coefficients >= 0.9991). Angular dependence was evaluated from - 90 degrees to + 90 degrees, and it was smaller in DE mode than in SE mode for OSLD. The normalized response of RPLD was higher at +/- 30 degrees and +/- 60 degrees and lower at - 90 degrees in SE and DE modes. This study demonstrated both OSLD and RPLD can perform dosimetry in dual-source DECT with small influence of the properties of the dosimeters compared with that in SECT.
引用
收藏
页码:1311 / 1319
页数:9
相关论文
共 26 条
  • [11] Dual-Energy CT: Clinical Applications in Various Pulmonary Diseases
    Kang, Mi-Jin
    Park, Chang Min
    Lee, Chang-Hyun
    Goo, Jin Mo
    Lee, Hyun Ju
    [J]. RADIOGRAPHICS, 2010, 30 (03) : 685 - 698
  • [12] Kato Hideki, 2011, Nihon Hoshasen Gijutsu Gakkai Zasshi, V67, P1320
  • [13] Lee Khan-yong, 2019, [The Journal of The Korean Association of Geographic and Environmental Education, 한국지리환경교육학회지], V27, P1, DOI 10.17279/jkagee.2019.27.2.1
  • [14] Evaluation of projection- and dual-energy-based methods for metal artifact reduction in CT using a phantom study
    Long, Zaiyang
    Bruesewitz, Michael R.
    DeLone, David R.
    Morris, Jonathan M.
    Amrami, Kimberly K.
    Adkins, Mark C.
    Glazebrook, Katrina N.
    Kofler, James M.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Halaweish, Ahmed F.
    Yu, Lifeng
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 252 - 260
  • [15] The applicability of radiophotoluminescence dosemeter (RPLD) for measuring medical radiation (MR) doses
    Manninen, A. -L.
    Koivula, A.
    Nieminen, M. T.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 1 - 9
  • [16] Accuracy of measuring half- and quarter-value layers and appropriate aperture width of a convenient method using a lead-covered case in X-ray computed tomography
    Matsubara, Kosuke
    Ichikawa, Katsuhiro
    Murasaki, Yuichi
    Hirosawa, Ayaka
    Koshida, Kichiro
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 309 - 316
  • [17] Moore WH., 2006, AM J ROENTGENOL, V187, P498, DOI [10.2214/AJR.05.1491, DOI 10.2214/AJR.05.1491]
  • [18] Patient exposure in medical X-ray imaging in Europe
    Regulla, DF
    Eder, H
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 11 - 25
  • [19] Rehani MM., 2000, ANN ICRP, V30, P7
  • [20] Development of radiophotoluminescence glass dosimeter usable in high temperature environment
    Sato, Fuminobu
    Zushi, Naoki
    Nagai, Tadaaki
    Tanaka, Teruya
    Kato, Yushi
    Yamamoto, Takayoshi
    Iida, Toshiyuki
    [J]. RADIATION MEASUREMENTS, 2013, 53-54 : 8 - 11