Use of optically stimulated luminescence dosimeter and radiophotoliminescent glass dosimeter for dose measurement in dual-source dual-energy computed tomography

被引:2
作者
Hirosawa, Ayaka [1 ,2 ]
Matsubara, Kosuke [3 ]
Morioka, Yusuke [1 ,2 ]
Kitagawa, Masayasu [1 ,2 ]
Chusin, Thunyarat [2 ,4 ]
Takemura, Akihiro [3 ]
机构
[1] Toyama Prefectural Cent Hosp, Dept Med Technol, 2-2-78 Nishinagae, Toyama, Toyama 9308550, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Quantum Med Technol, Div Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[4] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok 65000, Thailand
关键词
Dual-source dual-energy computed tomography (Dual-source DECT); Optically stimulated luminescence dosimeter (OSLD); Radiophotoluminescent glass dosimeter (RPLD); Dosimetry; EXPOSURE; NANODOT; OSLDS;
D O I
10.1007/s13246-021-01063-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to evaluate properties of optically stimulated luminescence dosimeters (OSLDs) and radiophotoluminescent glass dosimeters (RPLDs) used in dual-source dual-energy (DE) computed tomography (DECT) dosimetry. Energy dependence was evaluated in single-energy (SE) and DE modes, and their relative dose responses differed by 3.8% and 6.6% under equivalent effective energy with OSLD and RPLD, respectively. Dose variation was evaluated using coefficients of variation of dose values from 10 dosimeters, and dose variation of OSLD and RPLD in SE mode ranged from 2.1 to 3.0% and from 2.1 to 2.8%, and those in the DE mode were 1.8 and 2.6%, respectively. Dose linearity was evaluated from 1 to 150 mGy, and linear relationships of dose response were observed between the dosimeters and the ionization chamber (correlation coefficients >= 0.9991). Angular dependence was evaluated from - 90 degrees to + 90 degrees, and it was smaller in DE mode than in SE mode for OSLD. The normalized response of RPLD was higher at +/- 30 degrees and +/- 60 degrees and lower at - 90 degrees in SE and DE modes. This study demonstrated both OSLD and RPLD can perform dosimetry in dual-source DECT with small influence of the properties of the dosimeters compared with that in SECT.
引用
收藏
页码:1311 / 1319
页数:9
相关论文
共 26 条
  • [1] Characteristics of an OSLD in the diagnostic energy range
    Al-Senan, Rani M.
    Hatab, Mustapha R.
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4396 - 4405
  • [2] de Carvalho AB, 2012, MATER RES-IBERO-AM J, V15, P536, DOI [10.1590/S1516-14392012000400009, 10.1590/S1516-14392012005000075]
  • [3] Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT Scanners
    Diekmann, S.
    Siebert, E.
    Juran, R.
    Roll, M.
    Deeg, W.
    Bauknecht, H. -C.
    Diekmann, F.
    Klingebiel, R.
    Bohner, G.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) : 1003 - 1009
  • [4] Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations
    Giansante, Louise
    Martins, Juliana C.
    Nersissian, Denise Y.
    Kiers, Karen C.
    Kay, Fernando U.
    Sawamura, Marcia V. Y.
    Lee, Choonsik
    Gebrim, Eloisa M. M. S.
    Costa, Paulo R.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 308 - 320
  • [5] An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams
    Hill, Robin
    Mo, Zhao
    Haque, Mamoon
    Baldock, Clive
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 3971 - 3981
  • [6] Hirosawa Ayaka, 2015, Nihon Hoshasen Gijutsu Gakkai Zasshi, V71, P12, DOI 10.6009/jjrt.2015_JSRT_71.1.12
  • [7] Dosimetric comparison of different treatment modalities for stereotactic radiotherapy
    Hsu, Shih-Ming
    Lai, Yuan-Chun
    Jeng, Chien-Chung
    Tseng, Chia-Ying
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [8] International Organization for Standization, 2008, 983 ISO
  • [9] Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements
    Jursinic, Paul A.
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4594 - 4604
  • [10] Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams
    Kadoya, Noriyuki
    Shimomura, Kouhei
    Kitou, Satoshi
    Shiota, Yasuo
    Fujita, Yukio
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    Matsushita, Haruo
    Namito, Yoshihito
    Ban, Syuichi
    Koyama, Syuji
    Tabushi, Katsuyoshi
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5910 - 5916