Analysis by size exclusion chromatography of the graft terpolymer present in MBS
被引:0
|
作者:
Gutierrez, Carolina G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, ArgentinaUniv Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Gutierrez, Carolina G.
[1
,2
]
Minari, Roque J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, ArgentinaUniv Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Minari, Roque J.
[1
,2
]
Gugliotta, Luis M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, ArgentinaUniv Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Gugliotta, Luis M.
[1
,2
]
Meira, Gregorio R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, ArgentinaUniv Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Meira, Gregorio R.
[1
,2
]
Vega, Jorge R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, Argentina
Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, ArgentinaUniv Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
Vega, Jorge R.
[1
,2
,3
]
机构:
[1] Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, Argentina
[3] Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, Argentina
The molar mass distribution (MMD) and branching distribution (BD) of the graft terpolymer present in MBS (methyl methacrylate-butadiene-styrene, MMA-B-St) were estimated by size exclusion chromatography (SEC) with a series of three detectors: a UV photometer, a specific viscometer (SV), and a differential refractometer (DR). A solvent extraction procedure was employed to isolate the main MBS constituents: unreacted polybutadiene (PB), a PMMA-PS free copolymer (FC), and the PB-g-(PMMA-PS) graft terpolymer (GT). The FC was analyzed by UV + DR, yielding an almost uniform St mass fraction. The analysis of the GT involved the following assumptions: (i) the composition of the grafted branches coincides with that of the FC; (ii) the volumetric contractions of the molecules are represented by the Zimm-Stockmayer equations for randomly branched homopolymers; (iii) the low molar mass fraction exhibits a single branch per molecule; and (iv) the Mark-Houwink-Sakurada (MHS) parameters of the hypothetical homologous linear terpolymer are estimated by weighting the MHS constants of the PB and FC according to their mass fractions in the GT. The data treatment employed also enabled the branching exponent (epsilon) that relates the geometric and hydrodynamic contraction factors to be estimated, yielding epsilon approximate to 1.45.
机构:
Univ Western Sydney, Sch Biomed & Hlth Sci, Nanoscale Org & Dynam Grp, Penrith, NSW 1797, AustraliaUniv Western Sydney, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci, Penrith, NSW 1797, Australia
Gaborieau, Marianne
Castignolles, Patrice
论文数: 0引用数: 0
h-index: 0
机构:
Univ Western Sydney, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci, Penrith, NSW 1797, AustraliaUniv Western Sydney, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci, Penrith, NSW 1797, Australia