Analysis by size exclusion chromatography of the graft terpolymer present in MBS

被引:0
|
作者
Gutierrez, Carolina G. [1 ,2 ]
Minari, Roque J. [1 ,2 ]
Gugliotta, Luis M. [1 ,2 ]
Meira, Gregorio R. [1 ,2 ]
Vega, Jorge R. [1 ,2 ,3 ]
机构
[1] Univ Tecnol Nacl, Inst Desarrollo Tecnol Ind Quim INTEC, RA-3000 Santa Fe, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-3000 Santa Fe, Argentina
[3] Univ Tecnol Nacl, Fac Reg Santa Fe, RA-3000 Santa Fe, Argentina
关键词
Size exclusion chromatography (SEC); Graft terpolymer; Methyl methacrylate-butadiene-styrene (MBS); Branching distribution (BD); Branching exponent; N-BUTYL ACRYLATE; SEMIBATCH EMULSION POLYMERIZATION; METHYL-METHACRYLATE; MOLECULAR-WEIGHT; BRANCHED POLYMERS; LIGHT-SCATTERING; LIQUID-CHROMATOGRAPHY; COMPUTER-SIMULATION; MOLAR-MASS; STYRENE;
D O I
10.1007/s10965-014-0622-1
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The molar mass distribution (MMD) and branching distribution (BD) of the graft terpolymer present in MBS (methyl methacrylate-butadiene-styrene, MMA-B-St) were estimated by size exclusion chromatography (SEC) with a series of three detectors: a UV photometer, a specific viscometer (SV), and a differential refractometer (DR). A solvent extraction procedure was employed to isolate the main MBS constituents: unreacted polybutadiene (PB), a PMMA-PS free copolymer (FC), and the PB-g-(PMMA-PS) graft terpolymer (GT). The FC was analyzed by UV + DR, yielding an almost uniform St mass fraction. The analysis of the GT involved the following assumptions: (i) the composition of the grafted branches coincides with that of the FC; (ii) the volumetric contractions of the molecules are represented by the Zimm-Stockmayer equations for randomly branched homopolymers; (iii) the low molar mass fraction exhibits a single branch per molecule; and (iv) the Mark-Houwink-Sakurada (MHS) parameters of the hypothetical homologous linear terpolymer are estimated by weighting the MHS constants of the PB and FC according to their mass fractions in the GT. The data treatment employed also enabled the branching exponent (epsilon) that relates the geometric and hydrodynamic contraction factors to be estimated, yielding epsilon approximate to 1.45.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Analysis by size exclusion chromatography of the graft terpolymer present in MBS
    Carolina G. Gutierrez
    Roque J. Minari
    Luis M. Gugliotta
    Gregorio R. Meira
    Jorge R. Vega
    Journal of Polymer Research, 2015, 22
  • [2] Principles and potential of solvent gradient size-exclusion chromatography for polymer analysis
    Niezen, Leon E.
    Kruijswijk, Jordy D.
    van Henten, Gerben B.
    Pirok, Bob W. J.
    Staal, Bastiaan B. P.
    Radke, Wolfgang
    Philipsen, Harry J. A.
    Somsen, Govert W.
    Schoenmakers, Peter J.
    ANALYTICA CHIMICA ACTA, 2023, 1253
  • [3] Recent Advancements and Applications of Size Exclusion Chromatography in Modern Analysis
    Kumari, Yogindra
    Chopra, Arshdeep
    Bhatia, Rohit
    CURRENT ANALYTICAL CHEMISTRY, 2023, 19 (05) : 374 - 390
  • [4] Synthesis and Characterization of an Exact Polystyrene-graft-polyisoprene: A Failure of Size Exclusion Chromatography Analysis
    Lee, Sanghoon
    Lee, Hyojoon
    Chang, Taihyun
    Hirao, Akira
    MACROMOLECULES, 2017, 50 (07) : 2768 - 2776
  • [5] Extracellular vesicles isolated by size-exclusion chromatography present suitability for RNomics analysis in plasma
    Yang Yang
    Yaojie Wang
    Sisi Wei
    Chaoxi Zhou
    Jiarui Yu
    Guiying Wang
    Wenxi Wang
    Lianmei Zhao
    Journal of Translational Medicine, 19
  • [6] Extracellular vesicles isolated by size-exclusion chromatography present suitability for RNomics analysis in plasma
    Yang, Yang
    Wang, Yaojie
    Wei, Sisi
    Zhou, Chaoxi
    Yu, Jiarui
    Wang, Guiying
    Wang, Wenxi
    Zhao, Lianmei
    JOURNAL OF TRANSLATIONAL MEDICINE, 2021, 19 (01)
  • [7] The Past, the Present, and the Future of the Size Exclusion Chromatography in Extracellular Vesicles Separation
    Kaddour, Hussein
    Tranquille, Malik
    Okeoma, Chioma M.
    VIRUSES-BASEL, 2021, 13 (11):
  • [8] A retrospective look at developments in size exclusion chromatography from the early Hamielec research era to the present day
    McManus, Neil T.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2023, 101 (09) : 5365 - 5381
  • [9] Size-exclusion chromatography of perfluorosulfonated ionomers
    Mourey, T. H.
    Slater, L. A.
    Galipo, R. C.
    Koestner, R. J.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (34) : 5801 - 5809
  • [10] Applications of Size Exclusion Chromatography in Polymer Characterization
    Liu, Wei
    Liu, Yong-gang
    Ji, Xiang-ling
    ACTA POLYMERICA SINICA, 2021, 52 (09): : 1221 - 1244