Remote Monitoring of Patients With Heart Failure: A White Paper From the Heart Failure Society of America Scientific Statements Committee

被引:56
作者
Dickinson, Michael G. [1 ]
Allen, Larry A. [2 ]
Albert, Nancy A. [3 ]
Disalvo, Thomas [4 ]
Ewald, Gregory A. [5 ]
Vest, Amanda R. [6 ]
Whellan, David J. [7 ]
Zile, Michael R. [8 ]
Givertz, Michael M. [9 ]
机构
[1] Frederik Meijer Heart & Vasc Inst, Spectrum Hlth, 330 Barclay NE,Suite 200, Grand Rapids, MI 49503 USA
[2] Univ Colorado, Sch Med, Aurora, CO USA
[3] Cleveland Clin, Cleveland, OH 44106 USA
[4] Med Univ South Carolina, Charleston, SC 29425 USA
[5] Washington Univ, St Louis, MO USA
[6] Tufts Med Ctr, Boston, MA USA
[7] Thomas Jefferson Univ, Jefferson Med Coll, Philadelphia, PA 19107 USA
[8] Univ South Carolina, Charlotte, NC USA
[9] Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
关键词
Telehealth; CardioMEMS; heart failure; remote patient monitoring; PULMONARY-ARTERY PRESSURE; IMPLANTABLE ELECTRONIC DEVICES; RANDOMIZED CONTROLLED-TRIAL; RATE-VARIABILITY; COST-EFFECTIVENESS; MULTIDISCIPLINARY INTERVENTION; RISK STRATIFICATION; ELDERLY-PATIENTS; SMARTPHONE APPS; COMPASS-HF;
D O I
10.1016/j.cardfail.2018.08.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: After several neutral telehealth trials, the positive findings and subsequent Food and Drug Administration approval of an implantable pulmonary arterial pressure monitor (PAPM) led to renewed interest in remote patient monitoring (RPM). Here we seek to provide contemporary guidance on the appropriate use of RPM technology. Results: Although early trials of external RPM devices suggested benefit, subsequent multicenter trials failed to demonstrate improved outcomes. Monitoring features of cardiac implantable electronic devices (CIEDs) also did not deliver improved HF outcomes, newer, multisensor algorithms may be better. Earlier technologies using direct pressure measurement via implanted devices failed to show benefit owing to complications or failure. Recently, 1 PAPM showed benefit in a randomized controlled trial. Although not showing cost reduction, cost benefit analysis of that device suggests that it may meet acceptable standards. Additional research is warranted and is in progress. Consumer-owned electronic devices are becoming more pervasive and hold hope for future benefit in HF management. Practical aspects around RPM technology include targeting of risk populations, having mechanisms to ensure patient adherence to monitoring, and health care team structures that act on the data. Conclusions: Based on available evidence, routine use of external RPM devices is not recommended. Implanted devices that monitor pulmonary arterial pressure and/or other parameters may be beneficial in selected patients or when used in structured programs, but the value of these devices in routine care requires further study. Future research is also warranted to better understand the cost-effectiveness of these devices.
引用
收藏
页码:682 / 694
页数:13
相关论文
共 85 条
  • [51] Mobile Health Applications for the Most Prevalent Conditions by the World Health Organization: Review and Analysis
    Martinez-Perez, Borja
    de la Torre-Diez, Isabel
    Lopez-Coronado, Miguel
    [J]. JOURNAL OF MEDICAL INTERNET RESEARCH, 2013, 15 (06)
  • [52] Pulmonary artery pressure-guided heart failure management: US cost-effectiveness analyses using the results of the CHAMPION clinical trial
    Martinson, Melissa
    Bharmi, Rupinder
    Dalal, Nirav
    Abraham, William T.
    Adamson, Philip B.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 (05) : 652 - 660
  • [53] Rationale and Design of the Left Atrial Pressure Monitoring to Optimize Heart Failure Therapy Study (LAPTOP-HF)
    Maurer, Mathew S.
    Adamson, Philip B.
    Costanzo, Maria Rosa
    Eigler, Neal
    Gilbert, Joanne
    Gold, Michael R.
    Klapholz, Marc
    Saxon, Leslie A.
    Singh, Jagmeet P.
    Troughton, Richard
    Abraham, William T.
    [J]. JOURNAL OF CARDIAC FAILURE, 2015, 21 (06) : 479 - 488
  • [54] MedTech, 2016, ST JUD CARDIOMEMS HE
  • [55] Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors
    Mooney, Deirdre M.
    Fung, Erik
    Doshi, Rahul N.
    Shavelle, David M.
    [J]. FRONTIERS IN PHYSIOLOGY, 2015, 6
  • [56] A meta-analysis of remote patient monitoring for chronic heart failure patients
    Nakamura, Naoto
    Koga, Tadashi
    Iseki, Hiroshi
    [J]. JOURNAL OF TELEMEDICINE AND TELECARE, 2014, 20 (01) : 11 - 17
  • [57] The mobile revolution-using smartphone apps to prevent cardiovascular disease
    Neubeck, Lis
    Lowres, Nicole
    Benjamin, Emelia J.
    Ben Freedman, S.
    Coorey, Genevieve
    Redfern, Julie
    [J]. NATURE REVIEWS CARDIOLOGY, 2015, 12 (06) : 350 - 360
  • [58] Newman SP, WHOLE SYSTEM DEMONST
  • [59] Prospective study of heart rate variability and mortality in chronic heart failure - Results of the United Kingdom heart failure evaluation and assessment of risk trial (UK-Heart)
    Nolan, J
    Batin, PD
    Andrews, R
    Lindsay, SJ
    Brooksby, P
    Mullen, H
    Baig, W
    Flapan, AD
    Cowley, A
    Prescott, RJ
    Neilson, JMM
    Fox, KAA
    [J]. CIRCULATION, 1998, 98 (15) : 1510 - 1516
  • [60] Ollendorf DA, 2015, CARDIOMEMS HF SYSTEM