Remote Monitoring of Patients With Heart Failure: A White Paper From the Heart Failure Society of America Scientific Statements Committee

被引:56
作者
Dickinson, Michael G. [1 ]
Allen, Larry A. [2 ]
Albert, Nancy A. [3 ]
Disalvo, Thomas [4 ]
Ewald, Gregory A. [5 ]
Vest, Amanda R. [6 ]
Whellan, David J. [7 ]
Zile, Michael R. [8 ]
Givertz, Michael M. [9 ]
机构
[1] Frederik Meijer Heart & Vasc Inst, Spectrum Hlth, 330 Barclay NE,Suite 200, Grand Rapids, MI 49503 USA
[2] Univ Colorado, Sch Med, Aurora, CO USA
[3] Cleveland Clin, Cleveland, OH 44106 USA
[4] Med Univ South Carolina, Charleston, SC 29425 USA
[5] Washington Univ, St Louis, MO USA
[6] Tufts Med Ctr, Boston, MA USA
[7] Thomas Jefferson Univ, Jefferson Med Coll, Philadelphia, PA 19107 USA
[8] Univ South Carolina, Charlotte, NC USA
[9] Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
关键词
Telehealth; CardioMEMS; heart failure; remote patient monitoring; PULMONARY-ARTERY PRESSURE; IMPLANTABLE ELECTRONIC DEVICES; RANDOMIZED CONTROLLED-TRIAL; RATE-VARIABILITY; COST-EFFECTIVENESS; MULTIDISCIPLINARY INTERVENTION; RISK STRATIFICATION; ELDERLY-PATIENTS; SMARTPHONE APPS; COMPASS-HF;
D O I
10.1016/j.cardfail.2018.08.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: After several neutral telehealth trials, the positive findings and subsequent Food and Drug Administration approval of an implantable pulmonary arterial pressure monitor (PAPM) led to renewed interest in remote patient monitoring (RPM). Here we seek to provide contemporary guidance on the appropriate use of RPM technology. Results: Although early trials of external RPM devices suggested benefit, subsequent multicenter trials failed to demonstrate improved outcomes. Monitoring features of cardiac implantable electronic devices (CIEDs) also did not deliver improved HF outcomes, newer, multisensor algorithms may be better. Earlier technologies using direct pressure measurement via implanted devices failed to show benefit owing to complications or failure. Recently, 1 PAPM showed benefit in a randomized controlled trial. Although not showing cost reduction, cost benefit analysis of that device suggests that it may meet acceptable standards. Additional research is warranted and is in progress. Consumer-owned electronic devices are becoming more pervasive and hold hope for future benefit in HF management. Practical aspects around RPM technology include targeting of risk populations, having mechanisms to ensure patient adherence to monitoring, and health care team structures that act on the data. Conclusions: Based on available evidence, routine use of external RPM devices is not recommended. Implanted devices that monitor pulmonary arterial pressure and/or other parameters may be beneficial in selected patients or when used in structured programs, but the value of these devices in routine care requires further study. Future research is also warranted to better understand the cost-effectiveness of these devices.
引用
收藏
页码:682 / 694
页数:13
相关论文
共 85 条
  • [1] Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: complete follow-up results from the CHAMPION randomised trial
    Abraham, William T.
    Stevenson, Lynne W.
    Bourge, Robert C.
    Lindenfeld, Jo Ann
    Bauman, Jordan G.
    Adamson, Philip B.
    [J]. LANCET, 2016, 387 (10017) : 453 - 461
  • [2] The Role of Implantable Hemodynamic Monitors to Manage Heart Failure
    Abraham, William T.
    [J]. HEART FAILURE CLINICS, 2015, 11 (02) : 183 - +
  • [3] Wireless Pulmonary Artery Pressure Monitoring Guides Management to Reduce Decompensation in Heart Failure With Preserved Ejection Fraction
    Adamson, Philip B.
    Abraham, William T.
    Bourge, Robert C.
    Costanzo, Maria Rosa
    Hasan, Ayesha
    Yadav, Chethan
    Henderson, John
    Cowart, Pam
    Stevenson, Lynne Warner
    [J]. CIRCULATION-HEART FAILURE, 2014, 7 (06) : 935 - 944
  • [4] Adamson Philip B, 2011, Congest Heart Fail, V17, P248, DOI 10.1111/j.1751-7133.2011.00247.x
  • [5] CHAMPION Trial Rationale and Design: The Long-Term Safety and Clinical Efficacy of a Wireless Pulmonary Artery Pressure Monitoring System
    Adamson, Philip B.
    Abraham, William T.
    Aaron, Mark
    Aranda, Juan M., Jr.
    Bourge, Robert C.
    Smith, Andrew
    Stevenson, Lynne W.
    Bauman, Jordan G.
    Yadav, Jay S.
    [J]. JOURNAL OF CARDIAC FAILURE, 2011, 17 (01) : 3 - 10
  • [6] Evaluation of remote dielectric sensing (ReDS) technology-guided therapy for decreasing heart failure re-hospitalizations
    Amir, Offer
    Ben-Gal, Tuvia
    Weinstein, JeanMarc
    Schliamser, Jorge
    Burkhoff, Daniel
    Abbo, Aharon
    Abraham, William T.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 240 : 279 - 284
  • [7] Validation of remote dielectric sensing (ReDS™) technology for quantification of lung fluid status: Comparison to high resolution chest computed tomography in patients with and without acute heart failure
    Amir, Offer
    Azzam, Zaher S.
    Gaspar, Tamar
    Faranesh-Abboud, Suzan
    Andria, Nizar
    Burkhoff, Daniel
    Abbo, Aharon
    Abraham, William T.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 841 - 846
  • [8] Amir Offer, 2013, Congest Heart Fail, V19, P149, DOI 10.1111/chf.12021
  • [9] [Anonymous], 2015, MOBILE MED APPL GUID
  • [10] [Anonymous], 2013, WALL STR J