Investigation of the feasibility of non-invasive optical sensors for the quantitative assessment of dehydration

被引:0
作者
Visser, Cobus [1 ]
Kieser, Eduard [1 ]
Dellimore, Kiran [1 ]
van den Heever, Dawie [1 ]
Smith, Johan [2 ,3 ]
机构
[1] Stellenbosch Univ, Dept Mech & Mechatron Engn, Biomed Engn Res Grp, Stellenbosch, South Africa
[2] Tygerberg Hosp, Dept Paediat & Child Hlth, Durbanville, South Africa
[3] Stellenbosch Univ, Durbanville, South Africa
关键词
Hydration assessment; Infant dehydration; Objective measurement; Quantitative markers; CAPILLARY REFILLING TIME; DIAGNOSTIC-ACCURACY; HYDRATION; CHILDREN;
D O I
10.1016/j.medengphy.2017.06.036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study explores the feasibility of prospectively assessing infant dehydration using four non-invasive, optical sensors based on the quantitative and objective measurement of various clinical markers of dehydration. The sensors were investigated to objectively and unobtrusively assess the hydration state of an infant based on the quantification of capillary refill time (CRT), skin recoil time (SRT), skin temperature profile (STP) and skin tissue hydration by means of infrared spectrometry (ISP). To evaluate the performance of the sensors a clinical study was conducted on a cohort of 10 infants (aged 6-36 months) with acute gastroenteritis. High sensitivity and specificity were exhibited by the sensors, in particular the STP and SRT sensors, when combined into a fusion regression model (sensitivity: 0.90, specificity: 0.78). The SRT and STP sensors and the fusion model all outperformed the commonly used "gold standard" clinical dehydration scales including the Gorelick scale (sensitivity: 0.56, specificity: 0.56), CDS scale (sensitivity: 1.0, specificity: 0.2) and WHO scale (sensitivity: 0.13, specificity: 0.79). These results suggest that objective and quantitative assessment of infant dehydration may be possible using the sensors investigated. However, further evaluation of the sensors on a larger sample population is needed before deploying them in a clinical setting. (C) 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 32 条
  • [1] [Anonymous], 2007, J AM COLL NUTR, DOI DOI 10.1080/07315724.2007.10719661
  • [2] [Anonymous], 2004, CRIT CARE
  • [3] Near-IR spectroscopic imaging for skin hydration: The long and the short of it
    Attas, EM
    Sowa, MG
    Posthumus, TB
    Schattka, BJ
    Mantsch, HH
    Zhang, SLL
    [J]. BIOPOLYMERS, 2002, 67 (02) : 96 - 106
  • [4] An automated quasi-continuous capillary refill timing device
    Blaxter, L. L.
    Morris, D. E.
    Crowe, J. A.
    Henry, C.
    Hill, S.
    Sharkey, D.
    Vyas, H.
    Hayes-Gill, B. R.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2016, 37 (01) : 83 - 99
  • [5] Bordoley A, DIGIT AUTOMATE UNPUB
  • [6] Fluid resuscitation of hypovolemic shock: Acute medicine's great triumph for children
    Carcillo, Joseph A.
    Tasker, Robert C.
    [J]. INTENSIVE CARE MEDICINE, 2006, 32 (07) : 958 - 961
  • [7] How valid are clinical signs of dehydration in infants?
    Duggan, C
    Refat, M
    Hashem, M
    Wolff, M
    Fayad, I
    Santosham, M
    [J]. JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1996, 22 (01) : 56 - 61
  • [8] The Diagnostic Accuracy of Clinical Dehydration Scale in Identifying Dehydration in Children With Acute Gastroenteritis: A Systematic Review
    Falszewska, Anna
    Dziechciarz, Piotr
    Szajewska, Hania
    [J]. CLINICAL PEDIATRICS, 2014, 53 (12) : 1181 - 1188
  • [9] Development of a clinical dehydration scale for use in children between 1 and 36 months of age
    Frifdman, JN
    Goldman, RD
    Srivastava, R
    Parkin, PC
    [J]. JOURNAL OF PEDIATRICS, 2004, 145 (02) : 201 - 207
  • [10] External Validation and Comparison of Three Pediatric Clinical Dehydration Scales
    Jauregui, Joshua
    Nelson, Daniel
    Choo, Esther
    Stearns, Branden
    Levine, Adam C.
    Liebmann, Otto
    Shah, Sachita P.
    [J]. PLOS ONE, 2014, 9 (05):