Tomosynthesis implementation with adaptive online calibration on clinical C-arm systems

被引:10
作者
Chung, Khanlian [1 ]
Schad, Lothar R. [1 ]
Zoellner, Frank G. [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Mannheim, Germany
关键词
Circular tomosynthesis; Online calibration; Arbitrary scan trajectories; Cone beam computed tomography; Image-guided intervention; C-arm systems; CONE-BEAM CT; SELF-CALIBRATION; ASTRA TOOLBOX; BREAST; RECONSTRUCTION; PERFORMANCE; TOMOGRAPHY; PHANTOM;
D O I
10.1007/s11548-018-1782-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone beam computed tomography (CBCT) systems offer physicians crucial 3D and 2D imaging capabilities during interventions. However, certain medical applications only require very specific information from the CBCTs (e.g., determination of the position of high-contrast objects). In diagnostics, tomosynthesis techniques can be used in these cases to minimize dose exposure. Therefore, integrating such techniques on CBCT systems could also be beneficial for interventions. In this paper, we investigate the performance of our implementation of circular tomosynthesis on a CBCT device. The tomosynthesis scan trajectory is realized with step-and-shoot on a clinical C-arm device. The online calibration algorithm uses conventionally acquired 3D CBCT of the scanned object as prior knowledge to correct the imaging geometries. The online calibration algorithm was compared to an offline calibration to test its performance. A ball bearing phantom was used to evaluate the reconstructions with respect to geometric distortions. The evaluation was done for three different scenarios to test the robustness of our tomosynthesis implementation against object deviations (e.g., pen) and different object positioning. The circular tomosynthesis was tested on a ball bearing and an anthropomorphic phantom. The results show that the calibration is robust against isocenter shifts and object deviations in the CBCT. All reconstructions used 100 projections and displayed limited angle artifacts. The accuracy of the positions and shapes of high-contrast objects were, however, determined precisely. (The maximal center position deviation is 0.31 mm.) For medical procedures that primarily determine the precise position of high-contrast objects, circular tomosynthesis could offer an approach to reduce dose exposure.
引用
收藏
页码:1481 / 1495
页数:15
相关论文
共 26 条
  • [1] [Anonymous], BILDVERARBEITUNG MED
  • [2] A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections
    Chen, GH
    Leng, S
    Mistretta, CA
    [J]. MEDICAL PHYSICS, 2005, 32 (03) : 654 - 665
  • [3] Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    Chen, Guang-Hong
    Tang, Jie
    Leng, Shuai
    [J]. MEDICAL PHYSICS, 2008, 35 (02) : 660 - 663
  • [4] Chung K, 2017, FULLY3D 2017
  • [5] Digital breast tomosynthesis reconstruction with an adaptive voxel grid
    Claus, Bernhard
    Chan, Heang-Ping
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [6] Circular tomosynthesis for neuro perfusion imaging on an interventional C-arm
    Claus, Bernhard E.
    Langan, David A.
    Al Assad, Omar
    Wang, Xin
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [7] Geometry calibration phantom design for 3D imaging - art. no. 61422E
    Claus, Bernhard E. H.
    [J]. Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : E1422 - E1422
  • [8] MODEL-BASED OBJECT POSE IN 25 LINES OF CODE
    DEMENTHON, DF
    DAVIS, LS
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 1995, 15 (1-2) : 123 - 141
  • [9] Digital x-ray tomosynthesis: current state of the art and clinical potential
    Dobbins, JT
    Godfrey, DJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) : R65 - R106
  • [10] Task-driven image acquisition and reconstruction in cone-beam CT
    Gang, Grace J.
    Stayman, J. Webster
    Ehtiati, Tina
    Siewerdsen, Jeffrey H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) : 3129 - 3150