An ultrasensitive aptamer-antibody sandwich cortisol sensor for the noninvasive monitoring of stress state

被引:68
作者
Huang, Ziyu [1 ,2 ]
Chen, Hao [3 ]
Ye, Huarong [4 ]
Chen, Zixuan [5 ]
Jaffrezic-Renault, Nicole [6 ]
Guo, Zhenzhong [1 ]
机构
[1] Wuhan Univ Sci & Technol, Hubei Prov Key Lab Occupat Hazard Identificat & C, Wuhan 430065, Peoples R China
[2] Wuhan Univ Sci & Technol, Med Coll, Sch Publ Hlth, Wuhan 430065, Peoples R China
[3] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Anaesthesiol, Wuhan 430030, Peoples R China
[4] China Resources & Wisco Gen Hosp, Wuhan 430080, Peoples R China
[5] Wuhan Univ Sci & Technol, Med Coll, Dept Clin Med, Wuhan 430065, Peoples R China
[6] Univ Lyon, Inst Analyt Sci, UMR CNRS 5280, 5 La Doua St, F-69100 Villeurbanne, France
基金
中国国家自然科学基金;
关键词
Cortisol; Aptamer-antibody sandwich pattern; Sensor; Antibody-AuNPs conjugate; Saliva; Postgraduate; undergraduate; ELECTROCHEMICAL IMMUNOSENSOR; ASSAY; GRAPHENE; PROTEIN;
D O I
10.1016/j.bios.2021.113451
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Cortisol is a major glucocorticoid that can affect physiological activities in the human body. Besides, it is also a biomarker that can reflect the stress state of the body. Therefore, in order to monitor stress states in a sensitive and non-invasive manner, an ultra-sensitive aptamer-antibody sandwich sensor modified with multi-walled carbon nanotubes, ordered mesoporous carbon CMK-3, and silver nanoparticles (MWCNTs/CMK-3/AgNPs) was proposed for non-invasive detection of cortisol in human saliva. The MWCNTs/CMK-3/AgNPs nanocomposite was fixed on the surface of the glassy carbon electrodes (GCEs) as the material for the first round of signal amplification, and secondary signal amplification was realized by conjugating cortisol antibodies with gold nanoparticles (AuNPs). Finally, the aptamer-antibody sandwich pattern was used to specifically recognize and bind cortisol. The concentration response range for this aptamer-antibody sandwich sensor is 0.1 pg/mL-10 ng/mL, and the limit of detection (LOD) is 0.09 pg/mL. So far, the LOD of this sensor has been relatively low, showing its good sensitivity, selectivity, stability, and reproducibility. Furthermore, it has been successfully applied to detect cortisol in saliva samples to compare the stress states of postgraduates and undergraduates.
引用
收藏
页数:8
相关论文
共 38 条
[1]   Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models [J].
Burgues, Javier ;
Manuel Jimenez-Soto, Juan ;
Marco, Santiago .
ANALYTICA CHIMICA ACTA, 2018, 1013 :13-25
[2]   Microbial electrochemical sensor for water biotoxicity monitoring [J].
Chu, Na ;
Liang, Qinjun ;
Hao, Wen ;
Jiang, Yong ;
Liang, Peng ;
Zeng, Raymond Jianxiong .
CHEMICAL ENGINEERING JOURNAL, 2021, 404
[3]   Co3O4 needles on Au honeycomb as a non-invasive electrochemical biosensor for glucose in saliva [J].
Coyle, Victoria E. ;
Kandjani, Ahmad E. ;
Field, Matthew R. ;
Hartley, Patrick ;
Chen, Miao ;
Sabri, Ylias M. ;
Bhargava, Suresh K. .
BIOSENSORS & BIOELECTRONICS, 2019, 141
[4]   Batch fabrication of electrochemical sensors on a glycol-modified polyethylene terephthalate-based microfluidic device [J].
Cui, Feiyun ;
Jafarishad, Hamed ;
Zhou, Zhiru ;
Chen, Jiazhang ;
Shao, Jiahui ;
Wen, Qi ;
Liu, Yuxiang ;
Zhou, H. Susan .
BIOSENSORS & BIOELECTRONICS, 2020, 167
[5]   Aptamer-based lateral flow assay for point of care cortisol detection in sweat [J].
Dalirirad, Shima ;
Steckl, Andrew J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 :79-86
[6]   Chitosan-A versatile semi-synthetic polymer in biomedical applications [J].
Dash, M. ;
Chiellini, F. ;
Ottenbrite, R. M. ;
Chiellini, E. .
PROGRESS IN POLYMER SCIENCE, 2011, 36 (08) :981-1014
[7]   Highly sensitive and non-invasive electrochemical immunosensor for salivary cortisol detection [J].
Dhull, Nidhi ;
Kaur, Gurpreet ;
Gupta, Vinay ;
Tomar, Monika .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 293 :281-288
[8]   Synthesis and characterization of novel copper oxide-chitosan nanocomposites for non-enzymatic glucose sensing [J].
Figiela, Monika ;
Wysokowski, Marcin ;
Galinski, Maciej ;
Jesionowski, Teofil ;
Stepniak, Izabela .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 :296-307
[9]   Chemiluminescent assay as an alternative to radioimmunoassay for the measurement of cortisol in plasma and skin mucus of Oncorhynchus mykiss [J].
Franco-Martinez, L. ;
Tvarijonaviciute, A. ;
Martinez-Subiela, S. ;
Teles, M. ;
Tort, L. .
ECOLOGICAL INDICATORS, 2019, 98 :634-640
[10]   Label-free approach for electrochemical ferritin sensing using biosurfactant stabilized tungsten disulfide quantum dots [J].
Garg, Mayank ;
Chatterjee, Mary ;
Sharma, Amit L. ;
Singh, Suman .
BIOSENSORS & BIOELECTRONICS, 2020, 151