A Head-to-Head Analytical Comparison of Cobas 4800 HPV, PapilloCheck HPV Screening, and LMNX Genotyping Kit HPV GP for Detection of Human Papillomavirus DNA in Cervical and Cervicovaginal Swabs

被引:11
作者
Jaworek, Hana [1 ,4 ]
Koudelakova, Vladimira [1 ,4 ]
Drabek, Jiri [1 ,4 ]
Vrbkova, Jana [1 ,4 ]
Zborilova, Blazena [2 ,5 ]
Oborna, Ivana [3 ,5 ]
Brezinova, Jana [6 ]
Marek, Radim [3 ]
Huml, Karel [3 ]
Vanek, Peter [1 ,4 ]
Hajduch, Marian [1 ,4 ]
机构
[1] Palacky Univ Olomouc, Fac Med & Dent, Inst Mol & Translat Med, Olomouc, Czech Republic
[2] Palacky Univ Olomouc, Fac Med & Dent, Dept Biol, Olomouc, Czech Republic
[3] Palacky Univ Olomouc, Fac Med & Dent, Dept Obstet & Gynecol, Olomouc, Czech Republic
[4] Canc Res Czech Republ, Olomouc, Czech Republic
[5] Fertimed Ltd, Olomouc, Czech Republic
[6] Arleta IVF Ltd, Kostelec Nad Orlici, Czech Republic
关键词
HYBRID CAPTURE 2; CLINICAL VALIDATION; COLLECTED SAMPLES; CANCER; WOMEN; RISK; METAANALYSIS; ASSAYS; PERFORMANCE; POPULATION;
D O I
10.1016/j.jmoldx.2018.07.004
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
High-risk human papillomavirus (hrHPV) infection is a cause of cervical cancer development. The addition of hrHPV testing to cervical cancer screening and monitoring of cervical intraepithelial neoplasia treatment improves the efficacy of screening and treatment, respectively. Self-sampling for hrHPV testing seems a promising tool for increasing patient participation in cervical cancer screening. In this project, 1198 cervical swabs obtained by physicians and 176 cervicovaginal swabs obtained by self-sampling (not collected in parallel) were analyzed for the presence of 14 hrHPV genotypes using three commercially available assays in comparison. HPV DNA was detected in 21.2% of all samples (21% of cervical swabs and 22.7% of cervicovaginal swabs). The cobas 4800 HPV Test was the most sensitive (0.983) and specific (0.992) for hrHPV detection overall. The PapilloCheck HPV-Screening and LMNX Genotyping Kit HPV GP had comparable specificity with that of the cobas (0.989 and 0.955, respectively), but lesser sensitivity (0.897 and 0.909, respectively). In physician-obtained cervical swabs, the cobas showed the highest sensitivity and specificity (0.980 and 0.994, respectively) for hrHPV detection, whereas in cervicovaginal swabs, the cobas had the highest sensitivity (1.00), but the PapilloCheck had the highest specificity (0.993). In conclusion, all of the detection methods evaluated were highly sensitive and specific for hrHPV detection from both clinician-collected cervical swabs and self-sampled cervicovaginal swabs.
引用
收藏
页码:849 / 858
页数:10
相关论文
共 34 条
[1]   Which high-risk HPV assays fulfil criteria for use in primary cervical cancer screening? [J].
Arbyn, M. ;
Snijders, P. J. F. ;
Meijer, C. J. L. M. ;
Berkhof, J. ;
Cuschieri, K. ;
Kocjan, B. J. ;
Poljak, M. .
CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (09) :817-826
[2]   VALGENT: A protocol for clinical validation of human papillomavirus assays [J].
Arbyn, Marc ;
Depuydt, Christophe ;
Benoy, Ina ;
Bogers, Johannes ;
Cuschieri, Kate ;
Schmitt, Markus ;
Pawlita, Michael ;
Geraets, Daan ;
Heard, Isabelle ;
Gheit, Tarik ;
Tommasino, Massimo ;
Poljak, Mario ;
Bonde, Jesper ;
Quint, Wim .
JOURNAL OF CLINICAL VIROLOGY, 2016, 76 :S14-S21
[3]   Offering Self-Sampling Kits for HPV Testing to Reach Women Who Do Not Attend in the Regular Cervical Cancer Screening Program [J].
Arbyn, Marc ;
Castle, Philip E. .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2015, 24 (05) :769-772
[4]   Accuracy of human papillomavirus testing on self-collected versus clinician-collected samples: a meta-analysis [J].
Arbyn, Marc ;
Verdoodt, Freija ;
Snijders, Peter J. F. ;
Verhoef, Viola M. J. ;
Suonio, Eero ;
Dillner, Lena ;
Minozzi, Silvia ;
Bellisario, Cristina ;
Banzi, Rita ;
Zhao, Fang-Hui ;
Hillemanns, Peter ;
Anttila, Ahti .
LANCET ONCOLOGY, 2014, 15 (02) :172-183
[5]   Evidence Regarding Human Papillomavirus Testing in Secondary Prevention of Cervical Cancer [J].
Arbyn, Marc ;
Ronco, Guglielmo ;
Anttila, Ahti ;
Meijer, Chris J. L. M. ;
Poljak, Mario ;
Ogilvie, Gina ;
Koliopoulos, George ;
Naucler, Pontus ;
Sankaranarayanan, Rengaswamy ;
Peto, Julian .
VACCINE, 2012, 30 :F88-F99
[6]   A review of human carcinogens-Part B: biological agents [J].
Bouvard, Veronique ;
Baan, Robert ;
Straif, Kurt ;
Grosse, Yann ;
Secretan, Beatrice ;
El Ghissassi, Fatiha ;
Benbrahim-Tallaa, Lamia ;
Guha, Neela ;
Freeman, Crystal ;
Galichet, Laurent ;
Cogliano, Vincent .
LANCET ONCOLOGY, 2009, 10 (04) :321-322
[7]   Cervical Human Papillomavirus Prevalence in 5 Continents: Meta-Analysis of 1 Million Women with Normal Cytological Findings [J].
Bruni, Laia ;
Diaz, Mireia ;
Castellsague, Xavier ;
Ferrer, Elena ;
Bosch, F. Xavier ;
de Sanjose, Silvia .
JOURNAL OF INFECTIOUS DISEASES, 2010, 202 (12) :1789-1799
[8]   Human papillomavirus DNA testing for the detection of cervical intraepithelial neoplasia grade 3 and cancer: 5-year follow-up of a randomised controlled implementation trial [J].
Bulkmans, N. W. J. ;
Berkhof, J. ;
Rozendaal, L. ;
van Kemenade, F. J. ;
Boeke, A. J. P. ;
Bulk, S. ;
Voorhorst, F. J. ;
Verheijen, R. H. M. ;
Groningen, Kvan ;
Boon, M. E. ;
Ruitinga, W. ;
van Ballegooijen, M. ;
Snijders, P. J. F. ;
Meijer, C. J. L. M. .
LANCET, 2007, 370 (9601) :1764-1772
[9]   Comparing the performance of six human papillomavirus tests in a screening population [J].
Cuzick, J. ;
Cadman, L. ;
Mesher, D. ;
Austin, J. ;
Ashdown-Barr, L. ;
Ho, L. ;
Terry, G. ;
Liddle, S. ;
Wright, C. ;
Lyons, D. ;
Szarewski, A. .
BRITISH JOURNAL OF CANCER, 2013, 108 (04) :908-913
[10]   Analytical evaluation of the PapilloCheck test, a new commercial DNA chip for detection and genotyping of human papillomavirus [J].
Dalstein, Veronique ;
Merlin, Sandra ;
Bali, Corinne ;
Saunier, Maelle ;
Dachez, Roger ;
Ronsin, Christophe .
JOURNAL OF VIROLOGICAL METHODS, 2009, 156 (1-2) :77-83