A galvanic sensor for monitoring the corrosion damage of buried pipelines: Part 3 - Correlation of probe current to cathodic protection and stray current

被引:3
作者
Choi, Y.-S.
Kim, J.-G.
Koo, J.-Y.
机构
[1] Sungkyunkwan Univ, Dept Adv Mat Engn, Suwon 440746, South Korea
[2] Univ Seoul, Dept Environm Engn, Seoul 13074, South Korea
关键词
cathodic protection; corrosion monitoring system; corrosion sensor; galvanic couples; galvanic currents; pipeline; stray current;
D O I
10.5006/1.3278313
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to develop a new corrosion sensor for monitoring the status of cathodic protection of buried pipelines, the correlation of sensor output to protection abilities (protection potential and current) was evaluated using two types of laboratory tests. Me galvanic sensor uses the well-known principle of galvanic corrosion and consists of two dissimilar metals (acting as the anode and cathode) installed in the soil near the pipeline. In this paper, a copper-pipeline steel (Cu-CS) probe was used. The cathodic protection status of the pipeline was simulated by a galvanostatic test. The galvanic current density was measured using a zero-resistance ammeter for the Cu-CS probe with the anode (CS) either connected or disconnected to the pipeline. The results showed a good correlation between the protection potential/current of the pipeline and the sensor output. Especially when the protection current was induced to the pipeline, the measured sensor current was negative (-), whereas when the stray current was removed from the pipeline, the measured sensor current was positive (+). This indicates that the direction of sensor current reflects the status of the pipeline with cathodic protection or stray current corrosion, confirming that the Cu-CS galvanic probe is an effective tool for monitoring the effectiveness of cathodic protection.
引用
收藏
页码:951 / 957
页数:7
相关论文
共 19 条
[1]  
AGARWALA VS, 1996, CORR 96
[2]  
ANSUINI FJ, 2005, CORR 2005
[3]  
BARLO TJ, 1998, CORR 98
[4]   A galvanic sensor for monitoring the corrosion damage of buried pipelines: Part 2 - Correlation of sensor output to actual corrosion damage of pipeline in soil and tap water environments [J].
Choi, Y. -S. ;
Kim, J. -G. ;
Yang, S. J. .
CORROSION, 2006, 62 (06) :522-532
[5]   A galvanic sensor for monitoring the corrosion damage of buried pipelines: Part 1 - Electrochemical tests to determine the correlation of probe current to actual corrosion damage in synthetic groundwater [J].
Choi, YS ;
Kim, JG .
CORROSION, 2005, 61 (03) :293-301
[6]  
CHOI YS, 2003, CORR 2003
[7]  
CHOI YS, 2004, CORR 2004
[8]  
CHOI YS, 2005, CORR 2005
[9]  
FONTANA MG, 1986, CORROSION ENG, P383
[10]  
GAROSSHEN TJ, 2000, CORR 2000