Wide-field high-speed space-division multiplexing optical coherence tomography using an integrated photonic device

被引:22
作者
Huang, Yongyang [1 ,2 ]
Badar, Mudabbir [1 ,2 ]
Nitkowski, Arthur [3 ]
Weinroth, Aaron [3 ]
Tansu, Nelson [1 ,2 ]
Zhou, Chao [1 ,2 ,4 ]
机构
[1] Lehigh Univ, Dept Elect & Comp Engn, 27 Mem Dr W, Bethlehem, PA 18015 USA
[2] Lehigh Univ, Ctr Photon & Nanoelect, 27 Mem Dr W, Bethlehem, PA 18015 USA
[3] Tornado Spectral Syst Inc, 555 Richmond St West,Suite 402, Toronto, ON M5V 3B1, Canada
[4] Lehigh Univ, Dept Bioengn, Bethlehem, PA 18015 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2017年 / 8卷 / 08期
基金
美国国家科学基金会;
关键词
PROGRAMMABLE SWEPT-SOURCE; ANTERIOR SEGMENT; MEGAHERTZ OCT; DOMAIN OCT; 1310; NM; LASER; RESOLUTION; INTERFEROMETER; VISUALIZATION; MICROSCOPY;
D O I
10.1364/BOE.8.003856
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Space-division multiplexing optical coherence tomography (SDM-OCT) is a recently developed parallel OCT imaging method in order to achieve multi-fold speed improvement. However, the assembly of fiber optics components used in the first prototype system was labor-intensive and susceptible to errors. Here, we demonstrate a high-speed SDM-OCT system using an integrated photonic chip that can be reliably manufactured with high precisions and low per-unit cost. A three-layer cascade of 1 x 2 splitters was integrated in the photonic chip to split the incident light into 8 parallel imaging channels with similar to 3.7 mm optical delay in air between each channel. High-speed imaging (similar to 1s/volume) of porcine eyes ex vivo and wide-field imaging (similar to 18.0 x 14.3 mm(2)) of human fingers in vivo were demonstrated with the chip-based SDM-OCT system. (C) 2017 Optical Society of America
引用
收藏
页码:3856 / 3867
页数:12
相关论文
共 54 条
[21]   High-speed OCT light sources and systems [Invited] [J].
Klein, Thomas ;
Huber, Robert .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02) :828-859
[22]   Multi-MHz retinal OCT [J].
Klein, Thomas ;
Wieser, Wolfgang ;
Reznicek, Lukas ;
Neubauer, Aljoscha ;
Kampik, Anselm ;
Huber, Robert .
BIOMEDICAL OPTICS EXPRESS, 2013, 4 (10) :1890-1908
[23]   Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser [J].
Klein, Thomas ;
Wieser, Wolfgang ;
Eigenwillig, Christoph M. ;
Biedermann, Benjamin R. ;
Huber, Robert .
OPTICS EXPRESS, 2011, 19 (04) :3044-3062
[24]   Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle [J].
Kolb, Jan Philip ;
Klein, Thomas ;
Kufner, Corinna L. ;
Wieser, Wolfgang ;
Neubauer, Aljoscha S. ;
Huber, Robert .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (05) :1534-1552
[25]   Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns [J].
Kraus, Martin F. ;
Potsaid, Benjamin ;
Mayer, Markus A. ;
Bock, Ruediger ;
Baumann, Bernhard ;
Liu, Jonathan J. ;
Hornegger, Joachim ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06) :1182-1199
[26]   Scalable multiplexing for parallel imaging with interleaved optical coherence tomography [J].
Lee, Hee Yoon ;
Marvdashti, Tahereh ;
Duan, Lian ;
Khan, Saara A. ;
Ellerbee, Audrey K. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09) :3192-3203
[27]   Interleaved optical coherence tomography [J].
Lee, Hee Yoon ;
Sudkamp, Helge ;
Marvdashti, Tahereh ;
Ellerbee, Audrey K. .
OPTICS EXPRESS, 2013, 21 (22) :26542-26556
[28]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[29]   Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror [J].
Lu, Chen D. ;
Kraus, Martin F. ;
Potsaid, Benjamin ;
Liu, Jonathan J. ;
Choi, WooJhon ;
Jayaraman, Vijaysekhar ;
Cable, Alex E. ;
Hornegger, Joachim ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01) :293-311
[30]   Wide-field optical coherence microscopy of the mouse brain slice [J].
Min, Eunjung ;
Lee, Junwon ;
Vavilin, Andrey ;
Jung, Sunwoo ;
Shin, Sungwon ;
Kim, Jeehyun ;
Jung, Woonggyu .
OPTICS LETTERS, 2015, 40 (19) :4420-4423