The effects of physicochemical wastewater treatment operations on forward osmosis

被引:19
作者
Hey, Tobias [1 ,2 ,3 ]
Bajraktari, Niada [4 ,5 ]
Vogel, Jorg [4 ]
Nielsen, Claus Helix [4 ,5 ,6 ]
Jansen, Jes la Cour [3 ]
Jonsson, Karin [3 ]
机构
[1] VA SYD, POB 191, SE-20121 Malmo, Sweden
[2] Sweden Water Res AB, Lund, Sweden
[3] Lund Univ, Dept Chem Engn, Water & Environm Engn, Lund, Sweden
[4] Aquaporin AS, Lyngby, Denmark
[5] Tech Univ Denmark, Dept Environm Engn, Lyngby, Denmark
[6] Univ Maribor, Fac Chem & Chem Engn, Lab Water Biophys & Membrane Proc, Maribor, Slovenia
关键词
Forward osmosis; non-biological treatment; microfiltration; microsieve; physicochemical pretreatment; wastewater treatment; PRIMARY EFFLUENT; MEMBRANE; PERFORMANCE; SEWAGE; ULTRAFILTRATION; MICROFILTRATION; COAGULATION; REUSE; CLARIFICATION; PRETREATMENT;
D O I
10.1080/09593330.2016.1246616
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Raw municipal wastewater from a full-scale wastewater treatment plant was physicochemically pretreated in a large pilot-scale system comprising coagulation, flocculation, microsieve and microfiltration operated in various configurations. The produced microsieve filtrates and microfiltration permeates were then concentrated using forward osmosis (FO). Aquaporin Inside(TM) FO membranes were used for both the microsieve filtrate and microfiltration permeates, and Hydration Technologies Inc.-thin-film composite membranes for the microfiltration permeate using only NaCl as the draw solution. The FO performance was evaluated in terms of the water flux, water flux decline and solute rejections of biochemical oxygen demand, and total and soluble phosphorus. The obtained results were compared with the results of FO after only mechanical pretreatment. The FO permeates satisfied the Swedish discharge demands for small and medium-sized wastewater treatment plants. The study demonstrates that physicochemical pretreatment can improve the FO water flux by up to 20%. In contrast, the solute rejection decreases significantly compared to the FO-treated wastewater with mechanical pretreatment.
引用
收藏
页码:2130 / 2142
页数:13
相关论文
共 44 条
[1]   Treatment of primary effluent by coagulation-adsorption-ultrafiltration for reuse [J].
Abdessemed, D ;
Nezzal, G .
DESALINATION, 2003, 152 (1-3) :367-373
[2]   Performance comparison of direct membrane separation and membrane bioreactor for domestic wastewater treatment and water reuse [J].
Ahn, KH ;
Song, KG ;
Yeom, IT ;
Park, KY .
MEMBRANES IN DRINKING AND INDUSTRIAL WATER PRODUCTION II, 2001, 1 (5-6) :315-323
[3]  
Ahn KH, 1998, WATER SCI TECHNOL, V38, P373, DOI 10.2166/wst.1998.0671
[4]   Application of microfiltration with a novel fouling control method for reuse of wastewater from a large-scale resort complex [J].
Ahn, KH ;
Song, KG .
DESALINATION, 2000, 129 (03) :207-216
[5]   Removal of trace organic contaminants by the forward osmosis process [J].
Alturki, Abdulhakeem Ali ;
McDonald, James A. ;
Khan, Stuart J. ;
Price, William E. ;
Nghiem, Long D. ;
Elimelech, Menachem .
SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 103 :258-266
[6]  
Butler R, 1996, DESALINATION, V106, P273
[7]   The safe use of cationic flocculants with reverse osmosis membranes [J].
Chesters, S. P. ;
Darton, E. G. ;
Gallego, Silvia ;
Vigo, F. D. .
DESALINATION AND WATER TREATMENT, 2009, 6 (1-3) :144-151
[8]   Ultrafiltration enhanced by coagulation in an immersed membrane system [J].
Choksuchart, P ;
Héran, M ;
Grasmick, A .
DESALINATION, 2002, 145 (1-3) :265-272
[9]   The sweet spot of forward osmosis: Treatment of produced water, drilling wastewater, and other complex and difficult liquid streams [J].
Coday, Bryan D. ;
Xu, Pei ;
Beaudry, Edward G. ;
Herron, Jack ;
Lampi, Keith ;
Hancock, Nathan T. ;
Cath, Tzahi Y. .
DESALINATION, 2014, 333 (01) :23-35
[10]   Novel forward osmosis process to effectively remove heavy metal ions [J].
Cui, Yue ;
Ge, Qingchun ;
Liu, Xiang-Yang ;
Chung, Tai-Shung .
JOURNAL OF MEMBRANE SCIENCE, 2014, 467 :188-194