Chemometric-assisted spectrophotometric methods and high performance liquid chromatography for simultaneous determination of seven β-blockers in their pharmaceutical products: A comparative study

被引:15
作者
Hameed, Eman A. Abdel [1 ]
Salam, Randa A. Abdel [1 ]
Hadad, Ghada M. [1 ]
机构
[1] Suez Canal Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Ismailia 41522, Egypt
关键词
beta-Blockers; HPLC; Statistical experimental design; PCR; PLS; GA-PLS; RP-HPLC METHOD; EXPERIMENTAL-DESIGN; HPTLC METHODS; ATENOLOL; NEBIVOLOL; PHASE; HYDROCHLOROTHIAZIDE; PROPRANOLOL; CARVEDILOL; METOPROLOL;
D O I
10.1016/j.saa.2015.01.035
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Chemometric-assisted spectrophotometric methods and high performance liquid chromatography (HPLC) were developed for the simultaneous determination of the seven most commonly prescribed beta-blockers (atenolol, sotalol, metoprolol, bisoprolol, propranolol, carvedilol and nebivolol). Principal component regression PCR, partial least square PLS and PLS with previous wavelength selection by genetic algorithm (GA-PLS) were used for chemometric analysis of spectral data of these drugs. The compositions of the mixtures used in the calibration set were varied to cover the linearity ranges 0.7-10 mu g ml(-1) for AT, 1-15 mu g ml(-1) for ST, 1-15 mu g ml(-1) for MT, 0.3-5 mu g ml(-1) for BS, 0.1-3 mu g ml(-1) for PR, 0.1-3 mu g ml(-1) for CV and 0.7-5 mu g ml(-1) for NB. The analytical performances of these chemometric methods were characterized by relative prediction errors and were compared with each other. GA-PLS showed superiority over the other applied multivariate methods due to the wavelength selection. A new gradient HPLC method had been developed using statistical experimental design. Optimum conditions of separation were determined with the aid of central composite design. The developed HPLC method was found to be linear in the range of 0.2-20 mu g ml(-1) for AT, 0.2-20 mu g ml(-1) for ST, 0.1-15 mu g ml(-1) for MT, 0.1-15 mu g ml(-1) for BS, 0.1-13 mu g ml(-1) for PR, 0.1-13 mu g ml(-1) for CV and 0.4-20 mu g ml(-1) for NB. No significant difference between the results of the proposed GA-PLS and HPLC methods with respect to accuracy and precision. The proposed analytical methods did not show any interference of the excipients when applied to pharmaceutical products. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:278 / 286
页数:9
相关论文
共 48 条
[1]  
Ahsanul Hague M.D., 2010, DHAKA U J PHARM SCI, V9, P1816
[2]  
Al-Ghannam S.M., 2006, J PHARM BIOMED ANAL, V23, P151
[3]  
Anil K.S., 2004, BRAZ J PHARM SCI, P40
[4]   Simultaneous RP-HPLC Determination of Sotalol, Metoprolol, α-Hydroxymetoprolol, Paracetamol and Its Glucuronide and Sulfate Metabolites in Human Urine [J].
Baranowska, Irena ;
Wilczek, Andrzej .
ANALYTICAL SCIENCES, 2009, 25 (06) :769-772
[5]  
Belal F., 2013, J. Chromat. Separation Techniq., V4, P1
[6]   Multilevel multifactor designs for multivariate calibration [J].
Brereton, RG .
ANALYST, 1997, 122 (12) :1521-1529
[7]   Experimental design and multiple response optimization. Using the desirability function in analytical methods development [J].
Candioti, Luciana Vera ;
De Zan, Maria M. ;
Camara, Maria S. ;
Goicoechea, Hector C. .
TALANTA, 2014, 124 :123-138
[8]  
Chetan M.B., 2012, INT J RES PHARM BIOM, V3, P1594
[9]   Simultaneous determination of thirteen β-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection [J].
Delamoye, M ;
Duverneuil, C ;
Paraire, F ;
de Mazancourt, P ;
Alvarez, JC .
FORENSIC SCIENCE INTERNATIONAL, 2004, 141 (01) :23-31
[10]  
Durga K.B., 2011, INT J SCI INNOV DISC, V1, P151