Fast and simultaneous determination of phenolic compounds and caffeine in teas, mate, instant coffee, soft drink and energetic drink by high-performance liquid chromatography using a fused-core column

被引:135
|
作者
Rostagno, M. A. [1 ]
Manchon, N. [1 ]
D'Arrigo, M. [1 ]
Guillamon, E. [1 ]
Villares, A. [1 ]
Garcia-Lafuente, A. [1 ]
Ramos, A. [1 ]
Martinez, J. A. [1 ,2 ]
机构
[1] Inst Nacl Invest & Tecnol Agr & Alimentaria INIA, Ctr Calidad Alimentos, Soria 42004, Spain
[2] Univ Navarra, Dpto Fisiol & Nutr, Pamplona 31008, Spain
关键词
Fast separations; Phenolic acids; Flavan-3-ols; Flavones; Flavonols; Caffeine; HPLC; Fused-core; ISOFLAVONES; POLYPHENOLS; FOODS; ACIDS; NUTRACEUTICALS; EXTRACTION; VEGETABLES; PARTICLES; BEVERAGES; CATECHINS;
D O I
10.1016/j.aca.2010.11.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast HPLC method with diode-array absorbance detector and fluorescence detector for the analysis of 19 phenolic acids, flavan-3-ols, flavones, flavonols and caffeine in different types of samples was developed. Using a C-18 reverse-phase fused-core column separation of all compounds was achieved in less than 5 min with an overall sample-to-sample time of 10 min. Evaluation of chromatographic performance revealed excellent reproducibility, resolution, selectivity and peak symmetry. Limits of detection for all analyzed compounds ranged from 0.5 to 211 mu g L-1, while limits of quantitation ranged between 1.5 and 704 mu g L-1. The developed method was used for the determination of analytes present in different samples, including teas (black, white, green), mate, coffee, cola soft drink and an energetic drink. Concentration of the analyzed compounds occurring in the samples ranged from 0.4 to 314 mg L-1. Caffeine was the analyte found in higher concentrations in all samples. Phytochemical profiles of the samples were consistent with those reported in the literature. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 35 条
  • [31] Quantitative Determination of Spermidine in 50 German Cheese Samples on a Core-Shell Column by High-Performance Liquid Chromatography with a Photodiode Array Detector Using a Fully Validated Method
    Esatbeyoglu, Tuba
    Ehmer, Andreas
    Chaize, Delphine
    Rimbach, Gerald
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (10) : 2105 - 2111
  • [32] Chemometrics-enhanced high performance liquid chromatography-diode array detection strategy for simultaneous determination of eight co-eluted compounds in ten kinds of Chinese teas using second-order calibration method based on alternating trilinear decomposition algorithm
    Yin, Xiao-Li
    Wu, Hai-Long
    Gu, Hui-Wen
    Zhang, Xiao-Hua
    Sun, Yan-Mei
    Hu, Yong
    Liu, Lu
    Rong, Qi-Ming
    Yu, Ru-Qin
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1364 : 151 - 162
  • [33] Simultaneous determination of vanadium, niobium and tantalum by high-performance liquid chromatography equipped with on-line enrichment using 2-[2-(5-bromoquinolinylazo)]-5-diethylaminophenol as pre-column derivatization reagent
    Li, Ganpeng
    Wei, Qunyan
    Hu, Qiufen
    Huang, Zhangjie
    Yang, Guangyu
    MICROCHIMICA ACTA, 2007, 158 (1-2) : 95 - 102
  • [34] A sensitive method for extraction and determination of endocrine-disrupting compounds from wastewater using 10-ethyl-acridone-2-sulfonyl chloride as pre-column labeling reagent by high-performance liquid chromatography with fluorescence detection
    Zhang, Shijuan
    You, Jinmao
    Sun, Zhiwei
    Song, Cuihua
    Ning, Shujing
    Zhao, Changsheng
    Suo, Yourui
    MICROCHEMICAL JOURNAL, 2012, 103 : 90 - 96