Inferior Vena Cava Measurement with Ultrasound: What Is the Best View and Best Mode?

被引:67
作者
Finnerty, Nathan M. [1 ]
Panchal, Ashish R. [1 ]
Boulger, Creagh [1 ]
Vira, Amar [1 ]
Bischof, Jason J. [1 ]
Amick, Christopher [1 ]
Amick, Christopher [1 ]
Way, David P. [1 ]
Bahner, David P. [1 ]
机构
[1] Ohio State Univ, Coll Med, Dept Emergency Med, 750 Prior Hall,376 W 10th Ave, Columbus, OH 43210 USA
关键词
RIGHT ATRIAL PRESSURE; EMERGENCY-DEPARTMENT PATIENTS; CRITICALLY-ILL PATIENTS; SONOGRAPHIC MEASUREMENT; RESPIRATORY VARIATION; INTERRATER RELIABILITY; FLUID RESPONSIVENESS; HEALTHY-VOLUNTEERS; TRAUMA PATIENTS; VOLUME STATUS;
D O I
10.5811/westjem.2016.12.32489
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Intravascular volume status is an important clinical consideration in the management of the critically ill. Point-of-care ultrasonography (POCUS) has gained popularity as a non-invasive means of intravascular volume assessment via examination of the inferior vena cava (IVC). However, there are limited data comparing different acquisition techniques for IVC measurement by POCUS. The goal of this evaluation was to determine the reliability of three IVC acquisition techniques for volume assessment: subxiphoid transabdominal long axis (LA), transabdominal short axis (SA), and right lateral transabdominal coronal long axis (CLA) (aka "rescue view"). Methods: Volunteers were evaluated by three experienced emergency physician sonographers (EP). Gray scale (B-mode) and motion-mode (M-mode) diameters were measured and IVC collapsibility index (IVCCI) calculated for three anatomic views (LA, SA, CLA). For each IVC measurement, we calculated descriptive statistics, intra-class correlation coefficients (ICC), and two-way univariate analyses of variance. Results: EPs evaluated 39 volunteers, yielding 351 total US measurements. Measurements of the three views had similar means (LA 1.9 +/- 0.4cm; SA 1.9 +/- 0.4cm; CLA 2.0 +/- 0.5cm). For B-Mode, LA had the highest ICC (0.86, 95% CI [0.76-0.92]) while CLA had the poorest ICC (0.74, 95% CI [0.56-0.85]). ICCs for all M-mode IVCCI were low. Significant interaction effects between anatomical view and EP were observed for B-mode and M-mode measurements. Post-hoc analyses revealed difficulty in consistent view acquisition between EPs. Conclusion: Inter-rater reliability of the IVC by EPs was highest for B-mode LA and poorest for all M-Mode IVC collapsibility indices (IVCCI). These results suggest that B-mode LA holds the most promise to deliver reliable measures of IVC diameter. Future studies may focus on validation in a clinical setting as well as comparison to a reference standard.
引用
收藏
页码:496 / 501
页数:6
相关论文
共 29 条
  • [1] Akilli B, 2010, ULUS TRAVMA ACIL CER, V16, P113
  • [2] The interrater reliability of ultrasound imaging of the inferior vena cava performed by emergency residents
    Akkaya, Arif
    Yesilaras, Murat
    Aksay, Ersin
    Sever, Mustafa
    Atilla, Ozge Duman
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (10) : 1509 - 1511
  • [3] American College of Emergency Physicians, 2009, Ann Emerg Med, V53, P550, DOI 10.1016/j.annemergmed.2008.12.013
  • [4] Blehar DJ, 2012, CRIT ULTRASOUND J, V4, DOI 10.1186/2036-7902-4-18
  • [5] Identification of congestive heart failure via respiratory variation of inferior vena cava diameter
    Blehar, David J.
    Dickman, Eitan
    Gaspari, Romolo
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (01) : 71 - 75
  • [6] Trained Simulated Ultrasound Patients Medical Students as Models, Learners, and Teachers
    Blickendorf, J. Matthew
    Adkins, Eric J.
    Boulger, Creagh
    Bahner, David P.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (01) : 35 - 38
  • [7] Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality
    Boyd, John H.
    Forbes, Jason
    Nakada, Taka-aki
    Walley, Keith R.
    Russell, James A.
    [J]. CRITICAL CARE MEDICINE, 2011, 39 (02) : 259 - 265
  • [8] Reappraisal of the use of inferior vena cava for estimating right atrial pressure
    Brennan, J. Matthew
    Blair, John E.
    Goonewardena, Sascha
    Ronan, Adam
    Shah, Dipak
    Vasaiwala, Samip
    Kirkpatrick, James N.
    Spencer, Kirk T.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (07) : 857 - 861
  • [9] A comparison by medicine residents of physical examination versus hand-carried ultrasound for estimation of right atrial pressure
    Brennan, J. Matthew
    Blair, John E.
    Goonewardena, Sascha
    Ronan, Adam
    Shah, Dipak
    Vasaiwala, Samip
    Brooks, Erica
    Levy, Ari
    Kirkpatrick, James N.
    Spencer, Kirk T.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (11) : 1614 - 1616
  • [10] Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic
    Brennan, J. Matthew
    Ronan, Adam
    Goonewardena, Sascha
    Blair, John E. A.
    Hammes, Mary
    Shah, Dipak
    Vasaiwala, Samip
    Kirkpatrick, James N.
    Spencer, Kirk T.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (04): : 749 - 753