Heart Rate Estimation from Dual Pressure Sensors of a Dialysis Machine

被引:0
作者
Holmer, Mattias [1 ,2 ]
Sandberg, Frida [1 ]
Solem, Kristian [2 ]
Olde, Bo [2 ]
Sornmo, Leif [1 ]
机构
[1] Lund Univ, Dept Biomed Engn, Lund, Sweden
[2] Baxter Int Inc, Res Dept, Lund, Sweden
来源
2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC) | 2015年 / 42卷
关键词
SIGNAL;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Dialysis patients often suffer from cardiovascular diseases, motivating the use of continuous monitoring of cardiac activity in clinical routine. Cardiac pressure pulses propagate through the vascular system and enter the extracorporeal blood circuit of a dialysis machine, where the pulses are captured by pressure sensors. The cardiac pulses are obscured by the much stronger pressure pulses originating from the peristaltic blood pump. We have previously shown that a cardiac signal can be extracted from the venous pressure signal. However, that method has been found to perform less well at very low cardiac pressure pulse amplitudes. In the present study, we propose a novel method which addresses this issue by using the signals from both the arterial and the venous pressure sensors. The method is compared to the previous method on clinical data using a photoplethysmogram as reference. The results suggests that heart rate can be estimated more accurately from pressure signals with lower cardiac signal amplitude when both arterial and venous pressure are used, compared to when only the venous signal is used.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 7 条
  • [1] Extracting a Cardiac Signal From the Extracorporeal Pressure Sensors of a Hemodialysis Machine
    Holmer, Mattias
    Sandberg, Frida
    Solem, Kristian
    Grigonyte, Egle
    Olde, Bo
    Sornmo, Leif
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (05) : 1305 - 1315
  • [2] Pulse Rate Variability Analysis for Discrimination of Sleep-Apnea-Related Decreases in the Amplitude Fluctuations of Pulse Photoplethysmographic Signal in Children
    Lazaro, Jesus
    Gil, Eduardo
    Maria Vergara, Jose
    Laguna, Pablo
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (01) : 240 - 246
  • [3] Moissl U., 2002, P EUR MED BIOL ENG C, V3, P584
  • [4] Moissl U., 1999, P EUR MED BIOL ENG C, V37, pS558
  • [5] The acute cardiac effects of dialysis
    Selby, Nicholas M.
    McIntyre, Christopher W.
    [J]. SEMINARS IN DIALYSIS, 2007, 20 (03) : 220 - 228
  • [6] Sornmo Leif, 2012, IEEE Rev Biomed Eng, V5, P45, DOI 10.1109/RBME.2012.2210036
  • [7] US Renal Data System, 1996, AM J KIDNEY DIS, V28, P79