Screening for detection of new antidepressants, neuroleptics, hypnotics, and their metabolites in urine by GC-MS developed using rat liver microsomes

被引:65
作者
Bickeboeller-Friedrich, J [1 ]
Maurer, HH [1 ]
机构
[1] Univ Saarland, Inst Pharmacol & Toxicol, Dept Expt & Clin Toxicol, D-66421 Homburg, Germany
关键词
gas chromatography-mass spectrometry; antidepressants; neuroleptics; hypnotics; metabolism; liver microsomes;
D O I
10.1097/00007691-200102000-00012
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A gas chromatography-mass spectrometry (GC-MS) procedure for the detection of new antidepressants. neuroleptics. hypnotics, and their metabolites in urine is presented. The metabolites were first identified in rat liver microsome preparations by GC-MS after isolation and derivatization. Using these GC-MS data, a GC-MS screening was developed for urine as part of the authors' modified systematic toxicologic analysis procedure. After acid hydrolysis of a 2.5-ml aliquot of urine, a further aliquot was added. The mixture was then liquid-liquid extracted at pH 8-9, acetylated, and GC separated. Using mass chromatography with the ions m/z 58, 100, 120, 182, 195, 235, 261, 276, 284, and 293, the presence of new antidepressants. neuroleptics, hypnotics, and their metabolites could be indicated. Positive peaks could be identified by library search using the reference mass spectra recorded during the microsome studies. The intake of therapeutic doses of the following drugs could be monitored in urine: dosulepin, mirtazapine. moclobemide. nefazodone, trazodone, venlafaxine, and zolpidem. Olanzapine and zotepine were detectable in human urine only under steady-state conditions, and low-dose zopiclone was detectable only in overdose. The detection limit was less than 100 ng/mL (signal-to-noise ratio = 3) for the parent drugs.
引用
收藏
页码:61 / 70
页数:10
相关论文
共 41 条
[21]   Systematic toxicological analysis procedures for acidic drugs and/or metabolites relevant to clinical and forensic toxicology and/or doping control [J].
Maurer, HH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 733 (1-2) :3-25
[22]   Screening procedure for detection of antidepressants of the selective serotonin reuptake inhibitor type and their metabolites in urine as part of a modified systematic toxicological analysis procedure using cas chromatography-mass spectrometry [J].
Maurer, HH ;
Bickeboeller-Friedrich, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (05) :340-347
[23]   Gas chromatographic-mass spectrometric procedures for determination of the catechol-O-methyltransferase (COMT) activity and for detection of unstable catecholic metabolites in human and rat liver preparations after COMT catalyzed in statu nascendi derivatization using S-adenosylmethionine [J].
Maurer, HH ;
Bickeboeller-Friedrich, J ;
Kraemer, T .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (02) :325-335
[25]  
Maurer HH, 2000, COMB CHEM HIGH T SCR, V3, P467
[26]   SYSTEMATIC TOXICOLOGICAL ANALYSIS OF DRUGS AND THEIR METABOLITES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MAURER, HH .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 580 (1-2) :3-41
[27]  
MAURER HH, 2000, TOXICOL LETT, P112
[28]  
MAURER HH, 2000, MASS SPECTRAL GC D 4, P3
[29]  
MAURER HH, 1994, SPECTROSCOPY EUROPE, V6, P21
[30]  
Mclafferty F. W., 1993, INTERPRETATION MASS